![ZIEHL-ABEGG ECblue Series Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/ziehl-abegg/ecblue-series/ecblue-series_assembly-instructions-manual_933568045.webp)
11
Enclosure
11.1
Technical data
Line voltage*
(DC supply not UL and VDE approved!)
Voltage spezi
fi
cations see rating plate
DC voltage range
1 ~ 200...277 V, 50/60 Hz
280...400 V (+/- 2 %)
1 ~ 100...130 V, 50/60 Hz
140...400 V (+/- 2 %)
DC 110 V
110...400 V (+/- 2 %)
Maximal line fuse**
16 A
Max. load limit integral of cut-in current
approx.
2.0 A
2
s
Switching Freq.
16 kHz
Voltage supply for external devices
+10 V (-2 %), I
max
50 mA (short-circuit-proof)
Analogue input
“
E1
”
Input resistance: R
i
> 100 k
Ω
Speci
fi
cation speed setting signal PWM
Voltage: 15...28 VDC
Switching Frequency: 1...10 kHz
On-off ratio: 0...100 %
Digital input
“
D1
”
Input resistance: R
i
approx. 2 k
Ω
Voltage range high level: 7.1...19 V DC
Voltage range low level: 0....2.7 V DC
Open-Collector output
“
A1
”
I
max
: 20 mA
U
CE max
: 30 V DC
Contact rating of the internal relay
“
K1
”
AC 250 V 2 A
Permissible minimal and maximal ambi-
ent temperature for operation
-35...60
°
C (
rating plate) ***
Please see the technical documentation of the product for the minimum and max-
imum ambient temperature valid for the respective fan ; these may deviate from the
speci
fi
ed permissible ambient temperatures.
To avoid condensation the drive must be continuously energized due to the applica-
tion of heat, with interruptions such that cooling to the point of condensation does
not occur.
Max. permissible installation height
height 1000 m amsl without derating
Permissible rel. humidity
The motor is released for a relative humidity of 100 % at continental climate without
other ambient in
fl
uences. Other ambient conditions on request.
Permissible temperature range for stor-
age and transport
-40...+80
°
C
Electromagnetic compatibility for the
standard voltage 230 / 400 V according
to IEC 60038
Interference emission EN 61000-6-3 (domestic household applications)
Interference immunity EN 61000-6-2 (industrial applications)
Harmonics current
Active power factor adjustment for sinusoidal input current (PFC = Power - Factor -
controller), harmonic current in accordance with EN 61000-3-2 are guaranteed.
Max. leakage current according to the
de
fi
ned networks of EN 60990
< 3.5 mA
dB(A) values
product catalog
Ball bearings grease service-life (F
10h
)
during standard usage ca. 30 - 40,000 h
Protection class of motor according to
EN 60529
IP54
*
Regarding the mains connection, these devices are to be classi
fi
ed as category
“
C2
”
devices according to the relevant
DIN EN 61800-3. The increased requirements placed on electrical interference > 2 kHz for category
“
C1
”
devices are
complied with in addition.
**
Max. line fuse on site (line protection fuse) according to EN 60204-1 Classi
fi
cation VDE0113 Part 1 (see also Assembly
instructions / Electrical installation / Mains connection / Line protection fuse).
***
In case of a temperature increase above the predetermined threshold values modulation is linearly reduced by active
temperature management.
Assembly instructions
ECblue
Enclosure
L-BAL-F055D-GB 1634 Index 002
Part.-No.
45/51