9.
Setting of the Dosing Quantity
The adjustment screw in the quantity adjustment valve must be turned until the floater
upper edge has reached the desired quantity in liters/hour at the scale of the flow
measuring tube (see Diagram 7, Page 15).
For further information, see Section 8 Commissioning.
Diagram 16
The contact maker switches off the device as soon as the floater lowers itself (safety circuit).
At very small quantities, ensure that the floater is still able to lower, otherwise there is a risk that
the floater can not switch off although the flow rate has decreased to zero (risk of insufficient
dosage!!!).
At the standard device, the marking (scaling) at the flow measuring tube is 40
– 400 l/h. As the
function of the automatic shutoff can no longer be warranted for in the lowest range, there is the
option to insert a scaling of 15
– 150 l/h (see Spare Parts List, Page 23, Item 19).
Floater Upper Edge
Flow Measuring
Tube with Scale
Quantity Adjustment
Valve
Содержание PKT 452
Страница 2: ......
Страница 4: ......
Страница 13: ...Abb 4 Kontaktnehmer Kontaktnehmer Mitte Schwimmeroberkante Kontaktgeber ...
Страница 22: ...22 b Bildliche Darstellung des Schaltkastens Abb 9 K 3 K 1 K 2 ...
Страница 25: ...25 Bild 1 7 8 50 5 10 6 4 4 3 11 13 Bild 2 9 12 7 8 27 ...
Страница 26: ...26 Bild 3 Bild 4 15 13 11 4 9 10 14 4 4 7 6 9 ...
Страница 31: ......
Страница 34: ...34 ...
Страница 36: ...36 ...
Страница 45: ...45 Diagram 13 Contact Maker Contact Maker Center Cwenter Floater Upper Edge Contact Maker ...
Страница 54: ...54 b Graphic Presentation of the Control Box Diagram 18 K 3 K 1 K 2 ...
Страница 57: ...57 Image 1 7 8 50 5 10 6 4 4 3 11 13 Image 2 9 12 7 8 27 ...
Страница 58: ...58 Image 3 Image 4 15 13 11 4 9 10 14 4 4 7 6 9 ...
Страница 63: ...63 ...