Legs not working

Possible Cause

Remedy

 

Ξ Power Cable is not connected 

 

Ξ Legs are not connected 

 

Ξ Poor plug contact 

 

Ξ Control Unit is defective 

 

Ξ Remote Control is defective

 

Ξ Plug the Power Cable into the Control Unit 

 

Ξ Plug the Motor Cables into the Control Unit and Legs 

 

Ξ Check all connections 

 

 

Ξ Replace the Control Unit 

 

Ξ Replace the Remote Control

7. Troubleshooting

Possible Cause

Remedy

 

Ξ Mains power breakdown or main power is plugged off 

during movement 

 

Ξ Control Unit is defective 

 

Ξ Remote Control is defective 

 

Ξ Leg is defective

 

Ξ Zero setting (if movement is only possible downwards) 

 

 

Ξ Replace Control Unit 

 

Ξ Replace the Remote Control 

 

Ξ Replace the Leg

Legs only operating in one direction

Possible Cause

Remedy

 

Ξ Power Cable is not connected 

 

Ξ Remote Control is not connected 

 

Ξ Control Unit is defective 

 

Ξ Power Cable is defective 

 

Ξ Remote Control is defective 

 

Ξ Poor plug contact 

 

Ξ Exposed to liquids

 

Ξ Plug the power cable into the control unit 

 

Ξ Plug in the remote control 

 

 

Ξ Replace the Control Unit 

 

Ξ Replace the Power Cable 

 

Ξ Replace the remote control 

 

Ξ Check all connections 

 

Ξ Replace the remote control

Control Unit or Remote Control is not working

7.2 Error messages & Error code (Only on external remote with display)
The display reads HOT. 

Possible Cause

Remedy

 

Ξ The control unit is fitted with overheating  

protection. Overheating has caused it to 

stop the control unit

 

Ξ Wait until the control unit has cooled down and HOT is no longer displayed. The 

control unit is then operational again

The display reads E + an error code

NOTE: (If different error code than shown below, contact customer service)

Possible Cause

Remedy

 

Ξ There is an internal fault in the  

control unit

 

Ξ Proceed as indicated in the following list

Содержание e-ZGO 12 Series

Страница 1: ...ASSEMBLY GUIDE ENGLISH Rev 01 2021 04 27 e ZGO Series 12 22 ...

Страница 2: ... Stop postion 5 4 Change the displayed desktop position cm or inch 5 5 Saving a desktop position 5 6 Adjusting the desktop to a saved position 5 7 Reset control unit to factory settings 5 8 Changing the desktop height displayed 6 Programmable Remote Control Operating Instructions 6 1 Enter the setting menu 6 2 Change the displayed desktop position cm or inch 6 3 Intelligent system protection for d...

Страница 3: ...rface or it will not be steady Never exceed the maximum load capacity on the adjustable frame Please check the load capacity in Section 7 Specification The control unit is only used for specified linear actuator don t use appliances not recommended by the manufacturer 2 3 Specific Dangers When assembling and operating the adjustable frame make sure there is enough space to avoid collisions in all ...

Страница 4: ...1 Pcs ST 4 2x16 2 Pcs Before attempting assembly of the Height Adjustable Frame please read safety information in Section 2 Torque Guide Max torque M6 Screw s max torque 6nm M8 Screw s max torque 6nm M10 Screw s max torque 6nm Tapping screws is hand tightening only 3 2 Screw List Control Unit installing Card 1 Pcs M3 5X12 2 Pcs M6X25 8 Pcs Parts displayed above may vary based upon Frame Configurat...

Страница 5: ... refer to Torque Guide Step 2 Assemble the Leg and Frame as illustrated above Please refer to Torque Guide Step 3 Mount the End Pipe as illustrated above Step 5 Mount the Feet as illustrated above The smooth side of the plate faces the foot Please refer to Torque Guide ST 4 8x19 Step 6 Mount the Frame and End Pipe to the Table top as illustrated above Please refer to Torque Guide ...

Страница 6: ... as illustrated above Please refer to Torque Guide Step 9 Mount the Control Unit as illustrated above Step 10 Connect the Connection Cable to the Leg as illustrated above ST 3 5x12 Step 11 Mount the Remote Control to the Table top as illustrated above Please refer to Torque Guide Step 12 Perform Zero Setting Do not put power to the system before it is fully assembled ...

Страница 7: ...placed underneath the desktop A container stop position can be defined in the lower half of the movement area a shelf stop position in the upper half If a container stop position is set this position will be the lower limit position If a shelf stop position is set this position will be the new upper limit position To store a container stop shelf stop position go on as shown below Move the frame to...

Страница 8: ...n The display will read the current saved desktop position 6 Programmable Remote Control Operating Instructions The following actions should only be performed by properly trained personnel 6 1 Enter the setting menu Follow the instructions below to enter the setting menu to change the settings for the control unit Press the S button five seconds The display will read S X The display will start fla...

Страница 9: ...ot the actual position of the desktop Within the setting menu choose S 5 Press the S button to enter the setup menu Press the up or down button or to adjust the number for the height shown on the display Press the S button to finish the setup 6 7 Run automatically with memory position Follow the instructions below to change the run automatically with memory position function on or off Within the s...

Страница 10: ... Ξ Ξ Remote Control is not connected Ξ Ξ Control Unit is defective Ξ Ξ Power Cable is defective Ξ Ξ Remote Control is defective Ξ Ξ Poor plug contact Ξ Ξ Exposed to liquids Ξ Ξ Plug the power cable into the control unit Ξ Ξ Plug in the remote control Ξ Ξ Replace the Control Unit Ξ Ξ Replace the Power Cable Ξ Ξ Replace the remote control Ξ Ξ Check all connections Ξ Ξ Replace the remote control Cont...

Страница 11: ...le E07 Ξ Ξ Protect when the main power supply is running lower than 20V Power up again E08 Ξ Ξ Tilt when the desktop is running Re initialize HOT Ξ Ξ High power supply temperature or run over 2 minutes in 18 minutes Wait for the power temperature to drop and rerun E11 Ξ Ξ Motor 1 not connected Check the cable E12 Ξ Ξ Motor 1 Error in current sampling channel Replace the control panel E13 Ξ Ξ Motor...

Страница 12: ...line disconnect Check the hall signal or replace the cable E25 Ξ Ξ Motor 1 internal short circuit Replacing the motor E26 Ξ Ξ Motor 2 locked rotor Re initialize E27 Ξ Ξ Motor 2 wrong direction of operation Switch the motor line or hall line E28 Ξ Ξ Motor 2 overload Reduce load E40 Ξ Ξ Controller drop line in series Check the cable E41 Ξ Ξ Error in the series signal Check the cable or replace the c...