ASSEMBLY GUIDE
11
7. Troubleshooting
Error code Note
How to handle it
E01
Ξ The main supply voltage is over 45V
Check the main power supply
E02
Ξ The height deviation between the screws exceeds
1cm
Re-initialize
E04
Ξ Remote control connecting or communication
error
Check the remote control cable
- --
Ξ In the event of a drag-stop display
Release the button and run again
E06
Ξ Main power start did not succeed, lower than 20V Replace the main power supply, or check the main
power cable
E07
Ξ Protect when the main power supply is running,
lower than 20V
Power up again
E08
Ξ Tilt when the desktop is running
Re-initialize
HOT
Ξ High power supply temperature, or run over 2
minutes in 18 minutes
Wait for the power temperature to drop and rerun
E11
Ξ Motor 1 not connected
Check the cable
E12
Ξ Motor 1 Error in current sampling channel
Replace the control panel
E13
Ξ Motor 1 missing phase, phase line disconnect
Check if the motor is not properly connected to the line
E14
Ξ Motor 1 hall error, or hall line disconnect
Check the hall signal, or replace the cable
E15
Ξ Motor 1 internal short circuit
Replacing the motor
E16
Ξ Motor 1 locked-rotor
Re-initialize