6.2 System monitoring via Ethernet
User can monitor the inverter through the integrated ComBox with Ethernet module
(optional), The connection diagram between the inverter and internet with
network
cable is shown as follows.
Internet
LAN
Inverter_1
Inverter_n
Router
Internet
Solarcloud
LAN
LAN
Inverter_2
For connecting the network cable between the router and the Ethernet port on the
ComBox, please refer to the relative instruction at section 6.1.
The inverter obtains an IP address from the router via DHCP automatically and
shows it on the display. It takes time to connect to the network depending on the
network communication conditions.
Possible reason of communication failure due to DHCP
The router needs to support DHCP services if the ComBox use the DHCP
function.
Possible reason of communication failure due to closed port
The ComBox uses port #6655 and #80 to communicates with the Solarcloud.
Both of these two ports must be opened, or else the ComBox cannot
communicate with the Solarcloud and upload data.