Feature Set Reference
025-9368H
139
Log Errors in Call Detail Records
When the Call Detail Option (950-9587) has been installed, the Model 748 will log or record SMDR
(Station Message Detail Record) information on interconnect calls. This record includes time/date of
call, duration, user number and ANI against whom the call is billed, telephone number dialed and
call completion status. The Model 748 will also log errors such as invalid user number overdialed or
toll restriction invoked on telephone number dialed.
The Call Detail Option has the ability to store internally up to 4000 SMDR records for later
download or retrieval. Once the storage capacity has been reached, additional records are no longer
stored internally. To help maximize the value of data that is stored internally, the Model 748 allows
you to control or filter out which records are stored. All calls are always logged out the local RS-232
port in real time.
Log errors in Call detail records
lets you turn on or off the storage of errors such as invalid user
number overdialed or toll restriction invoked. All calls are always logged out the local RS-232 serial
port.
How to program it:
Access the Model 748 through your direct connected PC or terminal, or remotely from your PC
connected to a modem via the Model 748's internal modem.
Once connected to the Model 748 and the Main Menu is on the screen, type “4” and press
ENTER
,
the Accounting Menu will be displayed. Select the item number for
Log errors in Call detail records
and press
ENTER
.
The currently selected mode or state will be shown along with a message instructing you to press the
space bar to change the mode or state, and to press
ENTER
to accept the current mode or state. Each
time the space bar is pressed, the mode or state changes. Once the mode or state you desire is
displayed, press
ENTER
to accept it. Note that if you accidentally pass the mode or state you want,
keep pressing the space bar and the Model 748 will wrap around (when the last choice is displayed,
it will return to the first one).
The default setting is that “log errors” is disabled.
See also “Call Detail Logging” earlier in this section.
Содержание 748
Страница 2: ......
Страница 68: ...Operation 54 025 9368H Notes...
Страница 110: ...Programming 96 025 9368H Notes...
Страница 216: ...Feature Set Reference 202 025 9368H Notes...
Страница 219: ...Repair 025 9368H 205 MODEL 7XX AUDIO BLOCK DIAGRAM 006 0077A...
Страница 225: ...Repair 025 9368H 211 MODEL 7XX CONTROL BOARD 008 9793D Schematic Sheet 1 of 5...
Страница 226: ...Repair 212 025 9368H MODEL 7XX CONTROL BOARD SCHEMATIC 008 9793D Sheet 2 of 5...
Страница 227: ...Repair 025 9368H 213 MODEL 7XX CONTROL BOARD SCHEMATIC 008 9793D Sheet 3 of 5...
Страница 228: ...Repair 214 025 9368H MODEL 7XX CONTROL BOARD SCHEMATIC 008 9793D Sheet 4 of 5...
Страница 229: ...Repair 025 9368H 215 MODEL 7XX CONTROL BOARD SCHEMATIC 008 9793D Sheet 5 of 5...
Страница 230: ...Repair 216 025 9368H MODEL 7XX CONTROL BOARD 702 9793D Silkscreen...
Страница 233: ...Repair 025 9368H 219 MODEL 7XX SINGLE E E CARD 008 9794A Schematic...
Страница 234: ...Repair 220 025 9368H MODEL 7XX SINGLE E E CARD 702 9794A Silkscreen...
Страница 236: ...Repair 222 025 9368H MODEL 4XB VOICE CARD 008 9236F Schematic...
Страница 237: ...Repair 025 9368H 223 MODEL 4XB VOICE CARD 702 9236F Silkscreen...
Страница 239: ...Repair 025 9368H 225 MODEL 4XB DIAL CLICK BOARD 008 9242E Schematic...
Страница 240: ...Repair 226 025 9368H MODEL 4XB DIAL CLICK BOARD 702 9242E Silkscreen...
Страница 254: ...Quick Reference 240 025 9368H Notes...
Страница 258: ...Specifications 244 025 9368H...
Страница 259: ...Specifications 025 9368H 245...