Configuring the Digi One SP Device
34
025-9623 D3
Configuration Using a Browser
The final configuration of the Digi One module used to communicate with the iRIM
module is accomplished by logging onto the unit with a common Internet browser and
making the necessary changes. The easiest time to do this is right after you finish the first
phase of the module configuration using the tool provided by Digi International on CD-
ROM, while the module is still connected to the network.
For the purposes of this example, we will still be using the IP address information
. The serial port settings for the unit is listed in
Unlike the IP addresses (
which must be provided by the IT department controlling the
network on which the units will be installed
) this information will always be the same for
any Kenwood Radio Interface Module installation.
STOP
Warning!
Good cybersecurity practice requires changing the default
password immediately after logging in for the first time.
Continued use of default passwords is a significant security
vulnerability.
You will need to enter the default user name and the unique default password for the Digi
One module. A label on the device should have a unique default password for that device.
If there is no password information, or you don’t know the user name, contact Digi
International.
Table 6: Final Configuration of the Digit One™ SP Module
Parameter
Digi One Setting
NETWORK
no change
SERIAL PORT
Basic Serial Settings:
Advanced Serial Settings:
require user to login
Verbose connection (click “APPLY”)
No Change
No
No
SECURITY
No changes
SYSTEM
Optimization (click “APPLY”)
latency
A re-boot of each DIGI device is required after these configuration changes.