Function
code
Name
Description
Setting
range
Factory
default
F2.20
Maximum torque coefficient in
field weakening region
50-200%
100%
F2.21
Current loop M-axis proportional
coefficient
5-300
5
F2.22
Current loop M-axis integral
coefficient
0-65535
0
F2.23
Open loop vector velocity loop
filter time constant
0-100
25
F2.24
Open loop vector torque boost
0-500
100
F2.25
Open loop vector torque boost
cut-off frequency
Lower limit
frequency -
Max
frequency
20.00Hz
F2.26
Torque given filter
0-31
28
F2.27
Maximum field weakening
voltage overmodulation factor
0-110%
105%
F2.28
Magnetic flux observation
compensation factor
0-100%
100%
F2.29
Flux observation filter coefficient
0-2000
300
F2.30
T-axis current closed-loop
coefficient
0-500
0
F2.31
Reserved
F2.32
Reserved
F2.33
Reserved
F3.00
Start-up mode
0
:
Start frequency
1
:
DC start frequency
0-1
0
F3.01
Start frequency
Initial frequency of VFD start
0.50-20.00Hz
0.50hz
F3.02
Holding time of start frequency Start frequency run time
0.0-60.0s
0
F3.03
Start DC brking current
Current value for applying DC braking:
When the rated current of the motor is less than
or equal to 80% of the rated current of the VFD, it
is a percentage base value relative to the rated
current of the motor:
When the rated current of the motor is greater
than 80% of the rated current of the VFD, it is
relative to 80% of the rated current of the VFD as
the percentage base value.
0.0-100%
0.00%
F3.04
Start DC brking time
Duration of applying DC braking
0.0
~
100.0s
0.1s
F3.05
Stop mode
0
:
Decelerate stop
1
:
Decelerate stop + DC brking
2
:
Free stop
0-2
0
F3.06
Initial frequency for Stop DC
braking
When the frequency reaches the preset
frequency, DC braking starts
0.0-upper
limited
frequency
0.00Hz
F3.07
Stop DC brking current
Applying the same braking current value as DC
braking current
0.0-100%
0.00%
F3.08
Stop DC braking time
Duration of applying DC braking
0.0-30.0%
0.0s
F4.00
Jog forward running frequency
setting
F4.01
Jog reverse running frequency
setting
F4 group: Auxiliary Operation 2 Parameters
Set jog forward and reverse frequency
0.00-50.00Hz
10.00Hz
F3 group: Auxiliary Operation Parameters
1
1