Running / connecting cabling
www.zepro.com
Picture 42. Maximum power consumption - Minimum rec-
ommended conductor cross-sectional area
-
+
-
+
L
L
U
min
I
min
I
min
U
min
6
Running / connecting cabling
6.1
Maximum power consumption - Minimum recommended conductor cross-sectional area
Ensure that cable with sufficient wire area is used.
Hydraulic unit 7050
12 volt
24 Volt
Pump - Motor unit
245 A
145 A
Minimum recommended conductor cross-sectional area
(copper cables, plus and minus cables)
Control power cable
1.5 mm
2
1.5 mm
2
Main power cable, L < 8m
35 mm
2
35 mm
2
Main power cable, L = 8 - 15m
50 mm
2
35 mm
2
Main power cable, L > 15m
-
50 mm
2
Battery
Min. capacity, I
min
(available for lift)
180 Ah
170 Ah
Min. voltage during operation, U
min
(at lift)
9 Volt
18 Volt
NOTE!
Make sure the lift has
access to the minimum
recommended current ca-
pacity (I
min
)
.
Some vehicle
models have restrictions
regarding the amount of
power the lift can access
from the existing battery.