ZDK 250 135/155
Cable routing
39
www.zepro.com
5.4
Control power cable
When using cab switches (CS), route the control current cable from the cab switch CS to the tail lift cable
grommet. Connection is described later in section 6.
5.5
Open platform alarm
ZEPRO recommends the installation of an alarm for open platform. This can be in the form of warning light in the
cab or when mounted on a trailer, a lamp mounted on the outside of the body, visible in the rear view mirror from
the driver's cab. Route the lamp cables to the tail lift cable grommet. Connection is described later in section 6.
5.6
Foot controller / Warning lights
If the tail lift is equipped with warning lights and/or foot controller, their cabling must be routed and connected
according to the following description.
1. Connect the supplied cable to the connector on the foot controller/warning lighting cable.
2. Route the cable and install with cable ties according to Image 66 and Image 67. The quick connector
must be positioned in such a way that it does not conflict with the underrun protection while the lift arm
is in motion. Measure the distance (A) from the centre of the lift arm shaft to the centre of the underrun
protection; see Image 68.
3. Measure the same distance (A) on the lift arm; see Image 68.
4. Then place the quick connector at least 100 mm outside or inside the measured point (A); see Image 68.
Connection is described later in section 6.
IMPORTANT!
Route the cable between the platform and the lift arm tube such that it is well protected when the platform touches the ground.
Position the quick connector in such a way that it does not conflict with the underrun protection while the lift arm is in motion.
Leave enough slack to the first cable tie to avoid the risk of damage to the cable during lift operation.
Image 66. Installing cabling
Image 67. Installing cabling
Image 68. Quick con-
nector location
A
A
100 mm
200 mm
Содержание ZDK 250 135