iv - D2O FL1 Product Manual
6. SERIAL COMMANDS
18
6.1 INTRODUCTION
6.2 COMMAND LIST
6.3 COMMAND DETAILS
20
7. SPECIFICATIONS
27
7.1 TECHNICAL SPECIFICATIONS
7.2 REGULATORY & RADIATION INFORMATION
7.3 PRODUCT DIMENSIONS
28
8. TROUBLESHOOTING
29
8.1 OPERATIONAL TROUBLESHOOTING
8.2 SERIAL TERMINAL TROUBLESHOOTING
30
Страница 1: ...D2O FL1 Product Manual Version 1 1 May 2021 Zepiro...
Страница 2: ...hereof with no obligation to notify any persons of revisions or changes Zepiro does not assume any liability arising out of the application or any use of any product or circuit described herein neithe...
Страница 3: ...SITE SELECTION 7 3 3 MINIMUM CLEARANCE 9 3 4 PRE ASSEMBLY 9 3 5 D2O INTERFACE CABLE ATTACHMENT 10 3 6 POST MOUNTING 10 3 7 MAST MOUNTING 11 3 8 SECURING 11 4 WIRING GUIDE 12 4 1 INTRODUCTION 12 4 2 4...
Страница 4: ...ON 18 6 2 COMMAND LIST 18 6 3 COMMAND DETAILS 20 7 SPECIFICATIONS 27 7 1 TECHNICAL SPECIFICATIONS 27 7 2 REGULATORY RADIATION INFORMATION 27 7 3 PRODUCT DIMENSIONS 28 8 TROUBLESHOOTING 29 8 1 OPERATIO...
Страница 5: ...ourly measurements Messages are sent via a low earth orbit satellite network back to a terrestrial ground station From there Zepiro s servers securely recompile the data packets to readable formats an...
Страница 6: ...4 Pin M12 To USB A Cable The following item is available separately 1 4 ACCESSORY ITEMS 1 Antenna Base 2 Battery Switch 3 4 Pin M12 Connector Dust Cap 4 Product Identification Label 6 8 Pin M12 Conne...
Страница 7: ...st have a Serial Terminal software application installed on the operating system The D2O once connected to the computer by the 4 Pin M12 To USB A Cable is programmed by a Command Line Interface CLI us...
Страница 8: ...ividual message will vary within a 24hr period based on synchronisation time settings Device Integrity Info Basic information to indicate that the system is performing as intended without alert tamper...
Страница 9: ...e time activated when the internal tamper switch opens activates Fault Data Reports on faults Wire Fault Temperature Sensor Failure Other including the time that the first fault type was recorded the...
Страница 10: ...D2O has the greatest opportunity for a successful transmission or reception Satellite passes below 20 above the horizon have a lower probability of transmission Directly above the Antenna between 75 a...
Страница 11: ...D2O unit can see the most sky possible Where practical the D2O should always be the highest mounted object on top of a mounting post Avoid placing the D2O in the following locations In close proximit...
Страница 12: ...te and the light segments represent the ideal transmission angles A POOR SITE INSTALLATION 90 75 60 4 5 3 0 1 5 0 75 60 4 5 3 0 1 5 0 D2O E X A M P L E S A T E L L I T E P A S SES An improved site The...
Страница 13: ...en attached by screwing it on the exposed Antenna Base thread on the top of the D2O unit It should be tightened until the Antenna contacts the D2O Unit Do not over tighten the Antenna as irreparable d...
Страница 14: ...higher than the livestock could reach If prone to vandalism the D2O should be high enough to deter interference and may require additional protection mechanisms The D2O is capable of being mounted in...
Страница 15: ...fasten the grub screw The screw should only be tightened enough to stop easy rotation or removal of the device IMPORTANT NOTE Do not over tighten the grub screw It is possible to permanently damage th...
Страница 16: ...4 NOTE PIN 5 is often represented with a Grey colour if using other IEC 61076 2 101 standard cables FEMALE END VIEW The D2O FL1 can be connected to a flow meter using the 8 Pin M12 Interface Cable One...
Страница 17: ...erminate the Cable Screen to the device s earth CONNECTED DEVICE PIN 7 In instances where the 8 Pin M12 Interface Cable will be terminated into a junction such as a connector or breakout box the circu...
Страница 18: ...eration Before commencing any programming or commissioning tasks the following prerequisite tasks must be completed A 4 Pin M12 to USB A Cable must be available for connection between the D2O and a US...
Страница 19: ...able in other Serial Terminal Applications 1 Start Tera Term 2 On the New Connection Window select a Serial connection type From the drop down control select the Communications Port that corresponds t...
Страница 20: ...are set and that it will enter a normal operating mode once complete Use the CLI complete the following pressing the Enter key after each line noting the text entered is case sensitive 1 Enable the D2...
Страница 21: ...til deployment The D2O s Battery Power can be disabled by entering the below command This is an Admin Restricted command and cannot be set until the admin command has been executed sys p OFF Note the...
Страница 22: ...l Device Input Parameters The full list of available commands is shown below The Commands are shown in Bold text and available Parameters are shown in Regular text within brackets Detailed information...
Страница 23: ...k Parameters COMMAND SYNTAX DETAILS inp g Displays the total flow count that has been recorded in the specified engineering units since deployment inp z confirm Resets the pulse counter to zero Enter...
Страница 24: ...in the Serial Terminal software then the command will need to entered again upon waking the device Using this command will generate a notification message type advising of the login that will be sent...
Страница 25: ...still display in the Commission Report but will not execute until the apply command is used The returned date and time formats are Day Month Year Hour Minute Second in Greenwich Mean Time GMT Example...
Страница 26: ...aining 300 COMMAND SYNTAX DETAILS sys d Displays the Receiver s background noise level or RSSI Received Signal Strength Indicator in dBm This advanced diagnostics command queries the receiver backgrou...
Страница 27: ...To minimise the risk of saving a password with a typing mistake the parameter for password must be entered twice separated by a space The password itself must be a single continuous string of charact...
Страница 28: ...g interval and data sampled within 24h is synchronised to a GMT day Shifting the synchronisation time parameter hh in hours provides a means to align the D2O s first reading of the day to correspond t...
Страница 29: ...Kilolitre This is an Admin Restricted command and cannot be set until the admin command has been executed Example Setting the engineering unit to be L Litres acq u L OK COMMAND SYNTAX DETAILS acq p s...
Страница 30: ...ng that includes all readings ever recorded by the D2O since initial deployment Example inp g Total Flow 31 kL COMMAND SYNTAX DETAILS inp z confirm Resets the total accumulated pulse counter to zero E...
Страница 31: ...Ingress Protection IP Rating IP67 Pending Testing POWER Nominal Operating Voltage 3 0 to 3 6VDC Max System Standby Current 60 A TBC with Pulse Contact Open Nominal Non Rechargeable Battery Capacity 1...
Страница 32: ...28 D2O FL1 Product Manual 7 3 PRODUCT DIMENSIONS 161mm 122 5mm 93mm 117 5mm 317mm...
Страница 33: ...hut down The D2O Antenna becomes loose over time Ensure the Antenna s M4 Securing Grub Screw is firmly tightened against the Antenna Base of the D2O as per the Installation section Avoid over tighteni...
Страница 34: ...are correct If problems persist please contact your support representative for more detailed assistance The D2O is connected to the Serial Terminal software but is not responding Repeatedly press the...
Страница 35: ...D2O FL1 Product Manual 31 NOTES...
Страница 36: ...resources including manuals user instructions and datasheets are all available from the zepiro tech website For direct product support please contact your local distributor or a Zepiro representative...