D2O FL1 Product Manual - 19
COMMAND SYNTAX
DETAILS
time -g
Displays the verbose system time in GMT
Time Parameters
COMMAND SYNTAX
DETAILS
gps -g
Displays the last acquired GPS position as Latitude and Longitude with GMT time acquired
gps -v
Displays if the GPS Fix is Valid
Global Positions System (GPS) Parameters
COMMAND SYNTAX
DETAILS
acq -t
<hh>
Sets the Acquisition Synchronisation Time: Hour of Day (0 - 23) GMT.
Admin Restricted
acq -u
<unit>
Sets the pulse engineering unit transmitted to the server. Parameter at
<unit>
must be
one of:
NA
,
L
,
kL
,
ML
,
Gal
,
KGal
,
MGal
, or
m3
.
Admin Restricted
acq -p
<1 to 255>
Sets the pre-scale applied to the writing of the counter in between the hourly readings - a
battery saving feature. Counter will only get updated after the number of pulses set by the
parameter (1 to 255). Default is
100
.
Admin Restricted
Data Acquisition and Configuration Parameters
COMMAND SYNTAX
DETAILS
msg -g
Displays the date and time (GMT) of the next satellite transmission opportunity
Satellite Network Parameters
COMMAND SYNTAX
DETAILS
inp -g
Displays the total flow count that has been recorded, in the specified engineering units,
since deployment
inp -z
<confirm>
Resets the pulse counter to zero. Enter
CLEAR
at
<confirm>
to avoid accidental use.
Admin Restricted
Flow Meter Input Parameters
COMMAND SYNTAX
DETAILS
sys -c
Displays the Network Module Registration Code
sys -d
Displays the Receiver’s background noise level or RSSI (Received Signal Strength Indicator)
in dBm
sys -q
Displays the remaining storage space in the transmission queue in bytes
sys -L
Displays an estimate of the remaining power in the battery as a percentage (0% to 100%)
sys -p
<ON or OFF>
Sets the Battery’s Power Switch State to either
ON
or
OFF
. Setting to
OFF
is an
Admin
Restricted
command
sys -P
<password> <password>
Sets a new administrator password. The new password parameter must be entered twice,
separated by a space. Passwords must not contain whitespace. This is an
Admin Restricted
command
sys SC
<1000 to 50000> <pw>
Resets the battery capacity after replacement. Requires battery pack capacity to be entered
as well as a special password provided by Zepiro. Please contact your dealer for assistance
D2O Unit System Parameters