background image

24

A100K11211

SIP Master Stations Configuration

 

Pin 5/6 

Connect 24 VDC for station power if PoE 

 

   

is not used. Pin 6 is positive.

P4

  6-pin plug-on screw terminal for external connections.

 

Pin 1/4 

Input 1

 

Pin 2/4 

Input 2

 

Pin 3/4 

Input 3

 

Pin 5/6 

Station LED for call message info.

J4

 

18-pin ZIF-connector for keyboard.

The keyboard may have up to 10 dialling keys, M and C keys, 10 

DAK keys, 10 soft keys, volume up/down and light dim up/down keys 

connected in a matrix according to the drawing. 

J40

  Optional keyboard connection.

J41

   Optional DAK LED connection.

Connection to J40/J41 can either be to a pin header or soldered directly 

to holes in the PCB.

 

  J4 & J40 pin1-9 Keyboard matrix

 

  J4/10 - J41/1  DAK1 Green LED

 

  J4/11 - J41/2  DAK1 Red LED

 

  J4/12 - J41/3   DAK2 Green LED

 

  J4/13 - J41/4    DAK2 Red LED

 

  J4/14 - J41/5   DAK3 Green LED

 

  J4/15 - J41/6    DAK3 Red LED

 

  J4/16 - J41/7    DAK4 Green LED

 

  J4/17 - J41/8    DAK4 Red LED

 

  J4/18 - J41/9    3.3 V

The DAK keys and the DAK LEDs are programmed using IND commands 

in the Event Handler. DAKs 1 to 4 and Soft keys 1 to 4 are used in current 

master stations.

 

Privacy on/off is accomplished by pressing the 

C

 key for 3 seconds. A   

P

  

is shown in the display during Privacy mode.   

J5

 

20-pin ZIF connector for LCD display.

 

Separate display panels are available as a kit of 5 units (order no. 100 8099 000).

J1

 

RJ45 Connector for I2C interface.

 

Used for connection of DAK modules.

 

Pin 1 

GND

 

Pin 2 

A0 (GND)

 

Pin 3 

A1 (GND)

 

Pin 4 

NC (GND)

 

Pin 5 

IRQ

 

Pin 6 

SCL (Clock)

 

Pin 7 

SDA (Data)

 

Pin 8 

+13 V

J7

 

3-pin header for connecting gooseneck microphone.

 

Pin 1 

MIC+

 

Pin 2 

MIC-

 

Pin 3 

GND

J8

 

Dual RJ11 for handset and headset. 

 

Handset can optionally be connected via J11, J12 and J13.

LED

KEY1

KEY2

KEY3

C

A

1

6

J

4

0

J4

J

41

1

9

Dim

Down

Volume

Down

Volume

Up

Dim

Up

Soft

key 

10

Soft

key 

9

Soft

key 

8

Soft

key 

7

Soft

key 

6

Soft

key 

5

DAK

10

DAK

9

DAK

8

DAK

3

DAK

2

DAK

1

DAK

7

DAK

6

DAK

5

DAK

4

Soft

key 

4

Soft

key 

3

Soft

key 

2

Soft

key 

1

M C

9 8

5

7

4
2

6
3
1

0

J4 and J40 pin matrix

8        7        6        5        4        3        2        1

9

8

7

6

5

4

3

2

J1

1

2

3

4

5

6

7

8

1
3

+_

Содержание Vingtor Stentofon 1008015000

Страница 1: ...Configuration Manual SIP Master Stations A100K11211 TECHNICAL MANUAL...

Страница 2: ...Author Status 1 0 19 1 2012 HKL published 1 1 9 6 2017 HKL VS format SIP server Related Documentation For further information refer to the following documentation Doc no Documentation A100K10788 IP M...

Страница 3: ...Program 20 3 2 Manual Software Upgrade 20 3 3 Automatic Software Upgrade 21 4 Station Board Connections 23 5 Station Indication LEDs 26 5 1 Station LED 26 5 2 Status LED 26 5 3 Power LED 26 5 4 LAN L...

Страница 4: ...set The IP Desktop Master is a general purpose intercom station featuring a large high contrast display with backlight showing crystal clear information Ten direct access keys DAK provide single touch...

Страница 5: ...to the user according to priority and time of arrival The user can select which call to answer by scrolling through the queue Four direct access keys DAK provide single touch access to stations group...

Страница 6: ...tup menu 1 Press the Setup button on the left 2 Enter the password 1851 3 Press the Ok button Station mode If SIP settings is not listed as a main menu option select Station mode to set the station to...

Страница 7: ...Display Station Figure 4 RJ45 Ports on IP Flush OR Master Stations The factory default IP address of the station is 169 254 1 100 In order for your PC to communicate with the station it is necessary t...

Страница 8: ...button IP Settings DHCP Use this option if the SIP Station shall receive IP Settings from a DHCP server Static IP Use this option if the SIP Station shall use a static IP address Enter the IP address...

Страница 9: ...is the tertiary backup domain Authentication User Name This is the authentication user name used to register the station to the SIP server This is required only if the SIP server requires authenticat...

Страница 10: ...on event When enabled the station will activate the relay when receiving the specified DTMF character in the RTP stream Select from the dropdown menu Options are OFF 1 9 In call or Ringing The defaul...

Страница 11: ...se reduction of 36 3 dB Microphone Sensitivity Select the sensitivity level in the range 0 to 7 from the dropdown menu The default setting is 5 Remote Controlled Volume Override Mode This acts as simp...

Страница 12: ...ster stations have 10 Direct Access Keys and do not have the 3 Input Buttons described below Input Button 1 This is the SIP ID for the extension to be called when call button no 1 is pressed i e the S...

Страница 13: ...ion 4 Station Board Connections for more information 2 7 SNMP Settings SNMP Simple Network Management Protocol is a protocol for centralizing the management of devices in IP networks Click Advanced Co...

Страница 14: ...application is started Registration Successfull If enabled the station will send an SNMP trap when successfully registered in the SIP domain Registration Failed If enabled the station will send an SNM...

Страница 15: ...tation may be set up to automatically poll configuration settings for SIP Call and SNMP from a TFTP server The IP address of this TFTP server can be obtained using DHCP procedures or be manually confi...

Страница 16: ...uration procedure according to the set time interval 2 9 Advanced Configuration Options L L The configuration settings described in this section are not mandatory 2 9 1 VLAN VLAN Tagging or IEEE 802 1...

Страница 17: ...ackets or all packets The option ONLY TAGGED should only be used against VLAN aware devices which tag packets Select ONLY TAGGED or ALL from the dropdown menu VLAN priority tag to switch priority Here...

Страница 18: ...an authentication mechanism to devices wishing to attach to a LAN either establishing a point to point connection or preventing it if authentication fails L L STENTOFON SIP Stations support 802 1X as...

Страница 19: ...ted If TTLS with PAP or PEAP with MSCHAPV2 is chosen a certificate must be uploaded to the station by clicking Browse The certificate must either be in Privacy Enhanced Mail PEM or Distinguished Encod...

Страница 20: ...program must already be installed on your PC server with a defined IP address A free TFTP Server program can be downloaded from http tftpd32 jounin net Before starting the IP station upgrade procedur...

Страница 21: ...rer may be set to hide known file extensions so the file may appear without the bin extension The name of the software image file has to be entered with the extension bin 3 3 Automatic Software Upgrad...

Страница 22: ...enter the interval in minutes for checking updates The value must be between 1 and 999 and the default setting is 60 9 Click Save configuration for Updates The station will now contact the TFTP server...

Страница 23: ...ide RJ45 connector for auxiliary equipment like IP camera PC or a second IP sta tion This port does not have an individual IP address It does not carry power for AUX equipment P3 6 pin plug on screw t...

Страница 24: ...3 3 V The DAK keys and the DAK LEDs are programmed using IND commands in the Event Handler DAKs 1 to 4 and Soft keys 1 to 4 are used in current master stations Privacy on off is accomplished by pressi...

Страница 25: ...nced 0dBm 600 ohm Pin 1 13 V max 500 mA to amplifier Pin 2 LSN negative line Pin 3 LSP positive line Pin 4 GND Pin 5 AMP_EN enable signal to amplifier Pin 6 AMP_ERR error signal from amplifier J10 Int...

Страница 26: ...ossible reasons Station connected and registered to the SIP server Station not powered up if no other LEDs are active 5 2 Status LED LED3 Bicolor SMD LED on board component side Flashing 2 red 1 green...

Страница 27: ...5 4 LAN LEDs These LEDs are on the LAN P1 and AUX P2 RJ45 ports Left LED Steady light Ethernet connection OK Flashing Ethernet traffic No light No Ethernet connection Right LED Light 100 Mbit Ethernet...

Страница 28: ...ssword 1851 and press the Ok button 4 Navigate to Load defaults and press the Sel button 5 Press the Sel button again to load factory defaults The station will now restart with factory settings Statio...

Страница 29: ...interval Required No If this parameter is not set in the file the function will be disabled Description This parameter enables the station to automatically look for software updates on the TFTP server...

Страница 30: ...or fallback domain The IP address for the SIP domain server e g Asterisk or Cisco Call Manager should be defined in this section Values IP address given in regular dot notation e g 10 5 2 100 sip_doma...

Страница 31: ...ired No Description If desired an IP address can be configured as a backup for speeddial_1 If the station has no connection to any of the configured SIP domains it can call directly to this IP address...

Страница 32: ...value 0 9999 seconds 0 RTP timeout disabled remote_controlled_volume_override_mode Required No Description Acts as a simplex mode after first DTMF or is received from remote station Send DTMF to talk...

Страница 33: ...lues IP address given in regular dot notation e g 10 5 2 100 For example with an allowed network of 10 5 2 0 and a network mask of 24 anyone with IP address 10 5 2 0 to 10 5 2 255 can access the MIB n...

Страница 34: ...ription If enabled the station will send an SNMP trap if registration to the SIP domain failed Values 0 disabled 1 enabled enable_callConnect Required No Defaults to 1 Description If enabled the stati...

Страница 35: ...ster_interval 600 call speeddial_1 1000 speeddial_1_ip 10 5 2 200 speeddial_2 1004 speeddial_2_ip 10 5 2 201 speeddial_3 1005 speeddial_3_ip 10 5 2 202 speaker_volume 4 mic_sensitivity 5 rtp_timeout 6...

Страница 36: ...File The global configuration file has the same parameters as the device specific file except that the four parameters below will be ignored Hence it is recommended that the following parameters not b...

Страница 37: ...37 SIP Master Stations Configuration A100K11211...

Страница 38: ...g with Zenitel Any authorized reproduction in part or in whole must include this legend Zenitel All rights reserved The WEEE Directive does not legislate that Zenitel as a producer shall collect end o...

Отзывы: