background image

 

To Use This Product uafely !!

                                                         

 

 

Warning

 

         

 

 
 

Follow instruction

 

 

Follow instruction

 

 
 
 

Electrical Hazard

 

 

 
 

 
 

 
 

Caution 

 

 

Follow instruction

 

 
 
 
 

 
 

Caution

 

 
 
 
 

 

T o   U s e   T h i s   P r o d u c t   u a f e l y  

1. 

Before Power On 
Be sure to oPerate the Product with the sPecified Power suPPly. 
 

2. 

Environmental condition 
OPerating  temPerature:  0  to  40 

,  Humidity:  10  to  90%,  Use  the 

Product at the indoor Place where no corrosive gas is Present. 
 
 

3. 

Electrical Hazard 
Make sure that the Product is grounded safety. 
Be sure to use the green cable for grounding when you see the 2P-3P 
conversion adaPter. 
Before  rePlacing  the  fuse,  be  sure  to  turn  off  the  Power  switch  and 
disconnect the Power cable from the switchboard and Power outlet. 
Use the sPecified fuse for fire Prevention when rePlacing the fuse. 
 

4. 

Handling Precautions for the Power cable 
Do  not  susPend  the  device  in  midair  by  grabbling  the  Power  cable 
that is connected to the device. 
 

5. 

ProPer use of the device 
Do not remove the device cover. 
When  there  is  a  removal  instruction  of  the  device  cover  for  DIP 
switch  setting  in  the  User’s  manual,  be  sure  to  turn  off  the  Power 
switch  and  disconnect  the  Power  cable  from  the  switchboard  and 
Power outlet. 
Do not use at location subject to vibrations. 
 

6. 

RePairing 
If you find a malfunction, strange noise or unusual smell; 

 

Turn off the Power. 

 

Disconnect the AC adaPter or cable from the Power outlet. 

 

Do not remodel(decomPose/rePair) 

 

Make a request for rePair to your agent or uales DePartment of 

Zenisu Keisoku, Inc 

Содержание ZS-6103EG-F1

Страница 1: ...User s Manual High Speed GP IB Extender ZS 6103EG Series ZS 6103EG F1 ZS 6103EG F5...

Страница 2: ...the Power cable from the switchboard and Power outlet Use the sPecified fuse for fire Prevention when rePlacing the fuse Handling Precautions for the Power cable Do not susPend the device in midair by...

Страница 3: ...Table of Contents To Use This Product uafely 1 Outline 2 uPecification 3 Related Products 4 PreParation for use 5 OPerations 5 LED DisPlay 6 Precaution for use 6 APPearance 7...

Страница 4: ...GP IB information is converted to serial information by Zu 6103EG and transmitted through the dedicated cable We can Provide Zu 6103EG of the following tyPes in accordance with cable tyPe F1 FC TyPe...

Страница 5: ...eed MAX125kb sec MAX250kb sec Transmission distance MAX3km MAX1km Power DC 5V 400mA or less DC 5V 400mA or less Features Long transmission distance Low Price 2 GP IB standard ComPliant with IEEE 488 1...

Страница 6: ...R XX F5 tyPe inside Panel Zu F5ND XX F5 tyPe indoor use Zu F5ET XX F5 tyPe outdoor use Note inside Panel is aPPlicable for cabling inside the Protected tube or inside the Panel where Pressure and tens...

Страница 7: ...4 Confirm that POWER LED is lit on and other LEDs are not lit OPeration This unit conducts uerial Parallel u P conversion and Parallel uerial P u conversion using CODEC to ensure that cable can trans...

Страница 8: ...6103EG If you need to see directly it with the unaided eye Put PaPer or others in front of the connector and check the reflected light 2 Do not bend the oPtical fiber cable to radius less than 60mm Do...

Страница 9: ...7 APPearance OPtical cable oPtion...

Отзывы: