LED DisPlay 

LED lights in three colors dePending on the condition. 

 

The LED lit green color when the oPtical fiber cables are connected to each other and the Power 
cord is connected to DC. It indicates Power ON and communication enabled status. 

 

The LED lit red color when the oPtical fiber cables are connected to each other and the Power 
cord is connected to DC. It indicates an error occurs in transmission between cables. 

 

The LED lit blue color when the oPtical fiber cables are connected to each other and the Power 
cord is connected to DC. It indicates a status that data is being transmitted received from GP-IB. 

 

7.

Precautions for Use 

1

) 

Your eyes may be harmed when you see directly the oPtical connector of Zu-6103EG. If you 
need to see directly it with the unaided eye, Put PaPer or others in front of the connector and 
check the reflected light. 

2

) 

Do  not  bend  the  oPtical  fiber  cable  to  radius  less  than  60mm.  Do  not  give  a  strong  shock 
mechanically. 

3

) 

In case of F1(FC)model, fasten the inserted screws after checking the concave Part of device’s 
connector and the convex Part of cable’s connector. Fasten the screw to the end with force not 
too strong. 

4

) 

For the oPtical fiber cable connector of the F5model, be sure to insert securely. In this case, do 
not  griP  the  oPtical  fiber  cable  during  tightening.  Be  sure  to  insert  the  connector  while 
holding the connector body Part always. 

5

) 

Be  sure  not  to  aPPly  vibration  to  the  oPtical  connector  from  the  cable  or  others. 
Communication failure can be caused by shifting of oPtical axis. 

6

) 

When  you  want  to  use  the  oPtical  fiber  cable  outdoor,  be  sure  to  sPecify  the  outdoor  use 
always. 

 
 

Содержание ZS-6103EG-F1

Страница 1: ...User s Manual High Speed GP IB Extender ZS 6103EG Series ZS 6103EG F1 ZS 6103EG F5...

Страница 2: ...the Power cable from the switchboard and Power outlet Use the sPecified fuse for fire Prevention when rePlacing the fuse Handling Precautions for the Power cable Do not susPend the device in midair by...

Страница 3: ...Table of Contents To Use This Product uafely 1 Outline 2 uPecification 3 Related Products 4 PreParation for use 5 OPerations 5 LED DisPlay 6 Precaution for use 6 APPearance 7...

Страница 4: ...GP IB information is converted to serial information by Zu 6103EG and transmitted through the dedicated cable We can Provide Zu 6103EG of the following tyPes in accordance with cable tyPe F1 FC TyPe...

Страница 5: ...eed MAX125kb sec MAX250kb sec Transmission distance MAX3km MAX1km Power DC 5V 400mA or less DC 5V 400mA or less Features Long transmission distance Low Price 2 GP IB standard ComPliant with IEEE 488 1...

Страница 6: ...R XX F5 tyPe inside Panel Zu F5ND XX F5 tyPe indoor use Zu F5ET XX F5 tyPe outdoor use Note inside Panel is aPPlicable for cabling inside the Protected tube or inside the Panel where Pressure and tens...

Страница 7: ...4 Confirm that POWER LED is lit on and other LEDs are not lit OPeration This unit conducts uerial Parallel u P conversion and Parallel uerial P u conversion using CODEC to ensure that cable can trans...

Страница 8: ...6103EG If you need to see directly it with the unaided eye Put PaPer or others in front of the connector and check the reflected light 2 Do not bend the oPtical fiber cable to radius less than 60mm Do...

Страница 9: ...7 APPearance OPtical cable oPtion...

Отзывы: