ZEKS Eclipse

TM

 90-5,000ZPB Desiccant Dryers

www.zeks.com

23

9.0 MAINTENANCE AND SYSTEM CHECK

  

!

   WARNING

To avoid injury, depressurize dryer before performing any 

service.

  

!

   CAUTION

Desiccant will produce dust during the changeout procedure. 

Be sure to wear respiratory protection during the draining 

and 

fi

 

lling process to minimize inhalation of desiccant 

dust.

  

!

   WARNING

To avoid injury, depressurize dryer before performing any 

service.

9.3 CONTROL AIR SOLENOID VALVES AND 

      FILTER/REGULATOR

The length of time the Control Air Valves can reliably operate 

without replacement is dependent upon the dryer operating 

cycle. On -40°F dew point ZPB dryers, replacing the valves every 

36 months is recommended. For -80°F and -100°F dryers, it is 

recommended that the Control Air Valves be replaced every 6 

months. On NEMA 4 con

fi

 gured dryers, the Control Air Regulator 

pressure should be set for 100 PSI.

9.4 MUFFLER CHANGEOUT PROCEDURE

• Depressurize the dryer. Disconnect dryer from electric power 

source.

• Replace mu

  ers.

• Follow Start-up Procedure described in SECTION 8.8 of this 

Technical Manual.

• Turn control power back on.

9.5 ANGLE-SEAT PURGE AND SWITCHING VALVES

These valves have two control ports; one on top and the other on 

the back side of the bonnet.
• MAIN INLET FLOW VALVES - Normally-Open (N.O.) Valves: 

For inlet or re-pressurization valves, control air is supplied 

through tubing that is connected to the top port.

• PURGE VALVES - Normally-Closed (N.C.) Valves: For purge 

valves, control air is supplied through tubing that is connected 

to the side port. When control air is supplied to the valve, a 

position indicator will extend through the bonnet to indicate that 

the valve is open.

9.6 OUTLET CHECK VALVES

Outlet check valve sealing can be veri

fi

 ed by 

fi

 rst depressurizing 

the dryer and then slowly applying pressure to the dryer outlet. 

The valves should seal and prevent air from pressurizing the two 

dryer towers. If a tower begins to pressurize, the check valve on 

that side requires replacement.

9.7 DESICCANT CHANGEOUT PROCEDURE

When it becomes necessary to replace the desiccant in the 

towers, or on units that are shipped without the desiccant 

installed, observe the following procedure:

• The standard units are furnished with 

fi

 ll and drain ports on 

each desiccant tower. Remove the caps on both ports.

•  To assist in getting the desiccant to 

fl

 ow from the tower, insert a 

small rod into the drain port as necessary. This may be required 

as the desiccant is packed into the towers which may interfere 

with the free 

fl

 ow of desiccant from the towers.

• Retainer Screens, located at the inlet and outlet piping 

connections of each tower, are removable on all models. It is 

suggested that these Screens be removed and cleaned at the 

time of desiccant changeout. The Screens can be accessed 

by disconnecting the upper and lower manifolds from the dryer 

towers.

• After cleaning the retainer Screens, replace Screens and re-

insert the outlet port plug.

• With the 

fi

 ll port plug removed, 

fi

 ll the dryer tower with the 

appropriate grade and size desiccant. The level of the 

desiccant should be below the top retainer screen as shown on 

the Desiccant Fill Chart on the following page of this Technical 

Manual.

• When the towers have been 

fi

 lled to the correct level, reinsert 

the 

fi

 ll port plug on each tower.

•  Any connections and joints disturbed in the desiccant changeout 

procedure should be leak tested prior to re-commissioning the 

dryer.

9.2.1 FLANGED FILTER ELEMENT REPLACEMENT (Factory Installed Option)

STEP1- Using a 2” 
socket with an 
extension, 
carefully loosen 
element.

STEP 2- Remove 
old element from 
filter housing.

STEP 3 - Install 
new element by 
carefully inserting 
element in top 
plate.

STEP 4 - Hand 
tighten element 
in place until 
element o-ring 
contacts top plate.

STEP 5 - Using a 2” 
socket with an 
extension, tighten 
element one half 
turn. DO NOT 
OVERTIGHTEN.

STEP 6 - Repeat 
procedure as 
required to 
replace all 
elements.

  

!

   NOTICE

Should the dryer become overloaded, it 

may malfunction because of high pressure 

drop caused by a plugged after-

fi

 lter. 

Inspect after-

fi

 

lter element(s) frequently 

and replace when necessary to avoid this 

problem.

Содержание Eclipse 1000ZPB

Страница 1: ...w zeks com Form ZEKS ZPB V0121 ZPB Heatless Purge Desiccant Compressed Air Dryers 90 5 000 scfm NOTICE Those operating the machine or performing maintenance should read and understand the decals posit...

Страница 2: ...ZEKS EclipseTM 90 5 000ZPB Desiccant Dryers www zeks com...

Страница 3: ...NCLATURE 3 4 RECEIVING AND INSPECTION 3 5 SAFETY AND OPERATION PRECAUTIONS 4 6 PRINCIPLES OF OPERATION 5 7 ALARMS AND INDICATORS 15 8 INSTALLATION INITIAL START UP 18 9 SCHEDULED MAINTENANCE 22 10 TRO...

Страница 4: ...s from the date of equipment start up the Warranty Registration Card must be completed and returned to ZEKS Alternately the Warranty Registration Card may be completed online at www zeks com The total...

Страница 5: ...g fork tongs beneath these rails to avoid damaging piping at the rear of the dryer 4 0 RECEIVING AND INSPECTION NOTICE Nomenclature shown above represents standard price sheet options Other options ar...

Страница 6: ...ons OSHA Heading Descriptions 5 0 SAFETY AND OPERATION PRECAUTIONS ZEKS EclipseTM 90 5 000ZPB Desiccant Dryers www zeks com 4 NOTICE The user of any air dryer manufactured by ZEKS Compressed Air Solut...

Страница 7: ...ed to atmosphere The second stage of regeneration uses a portion of the dry compressed air expanded to atmospheric pressure to complete the desorption process As depicted in the P ID the compressed ai...

Страница 8: ...cycle is turned o 6 8 PURGESYNC FUNCTION with NEMA 4 Digital Controller option The PurgeSync function enables the dryer to reduce the timing of the purge cycle based on compressed air demand When this...

Страница 9: ...this screen the user can navigate to start stop monitor or alter the dryer Operating Cycle and test dryer functions CONTROLLER BUTTONS AND KEYS i INFORMATION BUTTON Restricted Level access for factory...

Страница 10: ...on Keys to highlight the value that needs to be changed 2 Press the button to change the value to the new setting ZPB Controller Display Display of dryer status program sequence information alarm stat...

Страница 11: ...thin that Step Jog Step Use key to jog the primary steps in the operating sequence TECHNICIAN MODE SCREEN 2 12 Dryer must be turned OFF and system or Control Air Circuit must be pressurized before ini...

Страница 12: ...rigger when measured value exceeds the high Dew Point setting HI DEWPT SETPOINT Value establishes the Alarm trigger point LO DEWPT ALM Choose ON or OFF In certain cases during low flow operation outle...

Страница 13: ...s not rise above this set point during the pressurization cycle for the tower that is designated for drying TECHNICIAN MODE SCREEN 11 12 This screen permits the user to set the Date and Time format th...

Страница 14: ...ce Reminder Interval for key components An alert will be displayed indicating that inspection replacement may be required when the time Interval is reached INLET FILTER Reminder Interval Weeks OUTLET...

Страница 15: ...conds RETRIES Default 3 attempts DELAY Default 10 minutes COMMUNICATIONS SCREEN 2 4 BAUD RATE Press Enter key to highlight field Press to select from preset values DATA BITS Default 8 For information...

Страница 16: ...Fail To Shift option OPERATING STATUS SCREEN 3 7 LT RT Left and Right Tower operating status DRYING or REGENERATING MLC SETPT Status of Moisture Load Control option ON or OFF Indication of Setpoint 40...

Страница 17: ...the towers during the drying and regeneration steps to ensure correct tower pressure values are maintained during each step The tower designated for regeneration should be under 7 PSI during this step...

Страница 18: ...n is true Activate while alarm condition is true Activated while alarm condition is true RECOMMENDED ACTION 1 Troubleshooting Sequence a Verify operation of purge valve Use test button on control air...

Страница 19: ...appear in two weeks Maintenance Alert A pop up ALERT will be displayed to indicate that the Filter Regulator element should be replaced If the user selects NO the reminder will be acknowledged and wi...

Страница 20: ...PREVENT FLOODING OF THE DESICCANT BED When all piping is connected all joints including those on the dryer should be soap bubble tested at line pressure to ensure no joints have been damaged in transi...

Страница 21: ...rotective packaging must not be installed until the dryer has been in operation for 24 hours Color of the Blue Moisture Indicator BMI must appear blue before the Transmitter is installed The dryer War...

Страница 22: ...ller to verify drain functionality after the dryer is placed into operation Drain maintenance or cleaning of system debris is not covered under the ZPB dryer warranty Improper drain maintenance will r...

Страница 23: ...ressurized in order for the main flow valves on the dryer to revert to the default position The status line in the Home screen will display OFF The system will remain pressurized at all times The drye...

Страница 24: ...t 7 days of operation SEMI ANNUAL MAINTENANCE FUNCTIONS Check outlet dew point MLC option only Check Control Air Filter NEMA 1 or Filter Regulator NEMA 4 element and clean or replace as required Repla...

Страница 25: ...t side requires replacement 9 7 DESICCANT CHANGEOUT PROCEDURE When it becomes necessary to replace the desiccant in the towers or on units that are shipped without the desiccant installed observe the...

Страница 26: ...20 38 134 100 34 160ZPB 22 00 29 75 192 150 50 200ZPB 14 00 21 50 236 177 59 250ZPB 23 00 28 00 290 215 75 300ZPB 12 00 21 25 344 258 86 400ZPB 11 00 22 25 470 352 118 500ZPB 27 00 32 00 638 478 160 6...

Страница 27: ...outlet of the dryer is piped to a booster compressor verify that the flow of the booster compressor is below the rated capacity of the dryer Excessive flow will fluidize desiccant bed and result in du...

Страница 28: ...0 Purge Air Flow SCFM Purge Meter Setting psig Dryer Model 160ZPB Purge Pressure Setting 50 psig 26 SCFM Purge Orifice 3 16 0 5 10 15 20 25 30 35 40 45 0 10 20 30 40 50 60 70 Purge Air Flow SCFM Purge...

Страница 29: ...70 80 90 100 110 120 130 0 10 20 30 40 50 60 70 Purge Air Flow SCFM Purge Meter Setting psig Dryer Model 500ZPB Purge Pressure Setting 35 psig 81 SCFM Purge Orifice 3 8 0 10 20 30 40 50 60 70 80 90 10...

Страница 30: ...0 180 210 240 270 300 330 360 0 10 20 30 40 50 60 70 Purge Air Flow SCFM Purge Meter Setting psig Purge Orifice 5 8 1800ZPA Setting 51 psig 292 SCFM 0 50 100 150 200 250 300 350 400 450 500 0 10 20 30...

Страница 31: ...urge Meter Setting psig Purge Orifice 7 8 3300ZPA Setting 47 psig 535 SCFM 0 100 200 300 400 500 600 700 800 900 1000 0 10 20 30 40 50 60 70 Purge Air Flow SCFM Purge Meter Setting psig Purge Orifice...

Страница 32: ...5479 5 7 2 1 7 94 7 57 88 7 259 942 9 7 3 433 9 43 459 43 1 19 7 5 0 3 57 19 7 459 43 1 89 5 79 1 9 9 7 19 7 459 43 1 19 7 5 0 24 39 3 41 8 8 39 11 5479 54 7 43 1 9 1 9 94 7 7 3 1 9 7 9 94 7 7 3 1 9 5...

Страница 33: ...7 94 7 57 88 7 259 942 9 7 3 433 9 43 459 43 1 19 7 5 0 3 57 19 7 459 43 1 19 7 5 0 89 5 79 1 9 9 7 19 7 459 43 1 24 39 3 41 8 8 39 11 5479 1 24 89 7 3 947 5 149 7 8 9 4 1 4 7 4 91 9 4 7 31 9 349 8 2...

Страница 34: ...9 43 1 19 7 5 0 24 39 3 41 8 1 97 1 3 148 7 5 149 7 19 7 1 24 89 7 3 947 54 7 43 1 9 1 9 94 7 7 3 1 9 7 9 94 7 7 3 1 9 5 149 7 8 9 4 1 5 5 4 7 4 91 9 4 7 31 9 59 7 4 91 9 433 9 43 59 7 31 9 433 9 43 G...

Страница 35: ...1 3 472 9 43 1 24 89 7 3 947 5 5 4 7 4 91 9 4 7 31 9 59 7 4 91 9 433 9 43 89 5 79 1 9 9 7 19 7 459 43 1 59 7 31 9 433 9 43 General Arrangement Dryer Models 160ZPB 200ZPB NEMA 4 Drawing No 47597121 34...

Страница 36: ...1 1 259 942 9 7 3 433 9 43 459 43 1 19 7 5 0 3 57 19 7 459 43 1 5 7 2 1 7 259 942 9 7 3 433 9 43 459 43 1 19 7 5 0 9 5 9 5 5 5 5 5 24 39 3 41 8 54 7 43 1 9 1 9 94 7 7 3 1 9 7 9 94 7 7 3 1 9 5 149 7 19...

Страница 37: ...459 43 1 19 7 5 0 3 57 19 7 459 43 1 5 7 2 1 7 259 942 9 7 3 433 9 43 459 43 1 19 7 5 0 5 149 7 19 7 7 1 947 5 149 7 8 9 4 1 9 5 9 5 5 5 5 5 24 39 3 41 8 1 24 89 7 3 947 7 31 9 433 9 43 59 5 59 5 5 5...

Страница 38: ...31 8 39 11 5479 94 7 57 88 7 7 1 1 3 57 19 7 459 43 1 5 7 2 1 7 259 942 9 7 3 433 9 43 459 43 1 19 7 5 0 89 5 79 1 9 9 7 19 7 459 43 1 24 39 3 41 8 5 149 7 8 9 4 1 5 149 7 19 7 1 24 89 7 3 947 54 7 43...

Страница 39: ...1 47 9 1 3 472 9 43 8 39 11 5479 94 7 57 88 7 7 1 1 3 57 19 7 459 43 1 5 7 2 1 7 259 942 9 7 3 433 9 43 459 43 1 19 7 5 0 89 5 79 1 9 9 7 19 7 459 43 1 24 39 3 41 8 1 24 89 7 3 947 4 7 4 91 9 9 5 4 7...

Страница 40: ...7 19 7 459 43 1 5 7 2 1 7 259 942 9 7 3 433 9 43 459 43 1 19 7 5 0 54 7 43 1 9 1 9 94 7 7 3 1 9 7 9 94 7 7 3 1 9 5 149 7 8 9 4 1 1 24 89 7 3 947 5 149 7 19 7 1 97 1 3 148 7 4 7 4 91 9 4 7 31 9 General...

Страница 41: ...3 459 43 1 19 7 5 0 7 1 1 3 57 19 7 459 43 1 5 7 2 1 7 259 942 9 7 3 433 9 43 459 43 1 19 7 5 0 1 24 89 7 3 947 4 7 4 91 9 4 7 31 9 General Arrangement Dryer Models 500ZPB 600ZPB NEMA 4 Drawing No 475...

Страница 42: ...14 359 7 4 91 9 433 9 43 359 7 31 9 433 9 43 89 5 79 1 9 9 7 19 7 459 43 1 19 7 5 0 1 9 3 8 55479 8 349 4 7 31 9 4 91 9 459 43 1 1 5 88 8 1 3 9 459 43 1 1 5 88 5 7 892 39 1 4 7 4 91 9 459 43 1 19 7 5...

Страница 43: ...9 942 9 7 3 433 9 43 459 43 1 5 0 9 5 9 5 459 43 1 94 7 38 1 9 43 8 4 3 9 8 431 5 7 14 359 7 4 91 9 433 9 43 359 7 31 9 433 9 43 89 5 79 1 9 9 7 19 7 459 43 1 19 7 5 0 1 9 3 8 55479 8 349 4 7 31 9 4 9...

Страница 44: ...2 1 7 459 43 1 94 7 38 1 9 43 9 8 431 5 7 892 39 1 5 7 14 7 1 3 7 4 91 9 433 9 43 1 9 3 8 55479 8 349 1 3 7 4 91 9 433 9 43 54 7 43 1 9 1 9 94 7 7 3 1 9 7 9 94 7 7 3 1 9 7 1 947 349 8 2 2 2 470 3 57 8...

Страница 45: ...8 39 11 5479 1 24 89 7 3 947 5 149 7 8 9 4 1 9 5 9 5 5 7 2 1 7 459 43 1 94 7 38 1 9 43 9 8 431 5 7 892 39 1 5 7 14 7 1 3 7 4 91 9 433 9 43 1 9 3 8 55479 8 349 1 3 7 4 91 9 433 9 43 349 8 2 2 2 470 3...

Страница 46: ...9 9 5 9 5 459 43 1 94 7 38 1 9 43 9 8 431 1 9 94 7 7 3 1 9 1 24 89 7 3 947 5 149 7 8 9 4 5 149 7 19 7 7 9 94 7 7 3 1 9 1 7 1 947 349 8 2 2 2 470 3 57 88 7 5 8 8 9 7 1 1 8 99 3 5 8 5 149 7 1 3 8 349 8...

Страница 47: ...7 892 39 1 7 1 3 7 4 91 9 433 9 43 1 3 7 31 9 433 9 43 5 149 7 19 7 7 1 947 5 149 7 8 9 4 1 9 5 9 5 459 43 1 94 7 38 1 9 43 9 8 431 349 8 2 2 2 470 3 57 88 7 5 8 8 9 7 1 1 8 99 3 5 8 5 149 7 1 3 8 34...

Страница 48: ...59 43 1 94 7 38 1 9 43 8 4 3 9 8 431 5 7 14 5 7 892 39 1 1 9 3 1 8 8 349 9 5 94 7 57 88 7 1 9 94 7 7 3 1 9 7 9 94 7 7 3 1 9 1 24 89 7 3 947 5 149 7 8 9 4 1 5 149 7 19 7 7 1 947 349 8 2 2 2 470 3 57 88...

Страница 49: ...1 I 4 7 31 9 8 39 7 3 5479 4 7 31 9 24 39 3 41 8 I 4 7 31 9 1 3 7 31 9 433 9 43 9 5 I 4 7 4 91 9 7 1 1 459 43 1 94 7 38 1 9 43 8 4 3 9 8 431 5 7 14 5 7 892 39 1 1 9 3 1 8 8 349 9 5 349 8 2 2 2 470 3 5...

Страница 50: ...4 7 43 1 9 9 5 9 5 I 4 7 31 9 8 39 7 3 5479 4 7 31 9 459 43 1 94 7 38 1 9 43 8 4 3 9 8 431 5 7 892 39 1 1 9 3 8 55479 8 349 4 349 1 9 7 7 57 88 7 9 43 1 1 9 94 7 7 3 1 9 7 9 94 7 7 3 1 9 5 149 7 8 9 4...

Страница 51: ...7 19 7 7 1 947 94 7 57 88 7 24 39 3 41 8 8 39 11 5479 1 24 89 7 3 947 5 149 7 8 9 4 1 9 5 9 5 I 4 7 31 9 8 39 7 3 5479 4 7 31 9 459 43 1 94 7 38 1 9 43 8 4 3 9 8 431 5 7 892 39 1 1 9 3 8 55479 8 349 4...

Страница 52: ...5 I 4 7 31 9 459 43 1 94 7 38 1 9 43 8 4 3 9 8 431 5 7 14 5 7 892 39 1 1 9 3 1 8 8 349 4 349 1 9 7 9 5 7 57 88 7 9 43 1 1 9 94 7 7 3 1 9 7 9 94 7 7 3 1 9 5 149 7 8 9 4 5 149 7 19 7 1 7 1 947 349 8 2...

Страница 53: ...1 8 8 349 4 349 1 9 7 9 5 7 57 88 7 9 43 1 12 0 GENERAL ARRANGEMENT ZEKS EclipseTM 90 5 000ZPB Desiccant Dryers www zeks com General Arrangement Dryer Model 5000ZPB NEMA 4 Drawing No 47597130 A 51 349...

Страница 54: ...am Dryer Model and Serial Number must be provided when ordering 2 23702244 Display Board Panel 3 634083 Overlay Controller 4 47587161001 Power Supply 5VDC 24VDC 5 38052411 Transducer Cable 5 Ft Lead F...

Страница 55: ...ZEKS EclipseTM 90 5 000ZPB Desiccant Dryers www zeks com 13 0 WIRING DIAGRAM Wiring Diagram NEMA 4 Standard Drawing No 47595562 53...

Страница 56: ...ZEKS EclipseTM 90 5 000ZPB Desiccant Dryers www zeks com 54 13 0 WIRING DIAGRAM Wiring Diagram NEMA 4 MLC Drawing No 47595563...

Страница 57: ...OLERANCES ARE CAD GENERATED DRAWING PROPRIETARY NOTICE NOTICE THIS DRAWING EMBODIES A CONFIDENTIAL PROPRIETARY DESIGN OWNED BY ZEKS AND ALL PATENT RIGHTS AND DESIGN MANUFACTURING THE SAME ARE EXPRESSL...

Страница 58: ...VE FV 2B RIGHT TOWER PURGE VALVE FV 1C LEFT TOWER OUTLET CHECK VALVE FV 2C RIGHT TOWER OUTLET CHECK VALVE FV 1P LEFT TOWER PURGE CHECK VALVE FV 2P RIGHT TOWER PURGE CHECK VALVE FV 4A LEFT TOWER INLET...

Страница 59: ...IN GAUGE FO 1 PURGE ORIFICE FO 4 REPRESSURIZATION ORIFICE NOTE 3 FV 1A LEFT TOWER INLET VALVE FV 2A RIGHT TOWER INLET VALVE FV 1B LEFT TOWER PURGE VALVE FV 2B RIGHT TOWER PURGE VALVE FV 1C LEFT TOWER...

Страница 60: ...IGHT TOWER PURGE MUFFLER FR 1 CONTROL AIR FILTER WITH REGULATOR AND BUILT IN GAUGE FLT 2 PREFILTER HIGH EFFICIENCY NOTE 4 FLT 3 AFTERFILTER DUST PARTICULATE NOTE 4 FO 1 PURGE ORIFICE FO 4 REPRESSURIZA...

Страница 61: ...SURIZATION ORIFICE NOTE 3 FV 1A LEFT TOWER INLET VALVE FV 2A RIGHT TOWER INLET VALVE FV 1B LEFT TOWER PURGE VALVE FV 2B RIGHT TOWER PURGE VALVE FV 1C LEFT TOWER OUTLET CHECK VALVE FV 2C RIGHT TOWER OU...

Страница 62: ...FFLER FR 1 CONTROL AIR FILTER WITH REGULATOR AND BUILT IN GAUGE FLT 2 PREFILTER HIGH EFFICIENCY NOTE 3 FLT 3 AFTERFILTER DUST PARTICULATE NOTE 3 FO 1 PURGE ORIFICE FO 4 REPRESSURIZATION ORIFICE NOTE 2...

Страница 63: ...ZEKS EclipseTM 90 5 000ZPB Desiccant Dryers www zeks com 61 14 0 FLOW DIAGRAM Flow Diagram 1800 2700 ZPB NEMA 4 Drawing No 47634360 A...

Страница 64: ...ZEKS EclipseTM 90 5 000ZPB Desiccant Dryers www zeks com 62 14 0 FLOW DIAGRAM Flow Diagram 3300 5000 ZPB NEMA 1 Drawing No 47634364 A...

Страница 65: ...ZEKS EclipseTM 90 5 000ZPB Desiccant Dryers www zeks com 63 14 0 FLOW DIAGRAM Flow Diagram 3300 5000 ZPB NEMA 4 Drawing No 47634361 A...

Страница 66: ...ENT AFTERFILTER PARTIC EC110G EC135G EC235G EC235G EC290G 1 1 1 2 DPI 2 3 GAUGE DIFF PRESSURE FILTER 634658 634658 634658 634658 634658 2 PI 1 2 3 GAUGE PURGE TOWER PRESS 680572 680572 680572 680572 6...

Страница 67: ...C350H EC470H EC600H EC600H 1 1 1 2 FLT 3 ELEMENT AFTERFILTER PARTIC EC350G EC470G EC600G EC600G 1 1 1 2 DPI 2 3 GAUGE DIFF PRESSURE FILTER 634658 634658 634658 634658 2 PI 1 2 3 GAUGE PURGE TOWER PRES...

Страница 68: ...920H EC1080H EC1350H EC1600H 1 1 1 2 FLT 3 ELEMENT AFTERFILTER PARTIC EC920G EC1080G EC1350G EC1600G 1 1 1 2 DPI 2 3 GAUGE DIFF PRESSURE FILTER 634658 634658 634658 634658 2 PI 1 2 3 GAUGE PURGE TOWER...

Страница 69: ...C EF600G 3 EF600G 4 EF600G 5 EF600G 6 EF600G 7 EF600G 10 Qty 1 Set 1 Set 2 Sets DPI 2 3 GAUGE DIFF PRESSURE FILTER 633353 633353 633353 633353 633353 633353 2 PI 1 2 3 GAUGE PURGE TOWER PRESS 631324 6...

Страница 70: ...O N O 47607077006 47607078006 47590672001 VALVE ANGLE 2 P O N C 47607077007 47607078007 47607080002 47590670001 VALVE ANGLE 2 P O N O 47607077008 47607078008 47590671001 VALVE ANGLE 2 P O N O 47607077...

Страница 71: ...705001 SP Blue Moisture Indicator CONTROL AIR SOLENOID and FILTER REGULATOR ASSEMBLY Optional Dew Point Transmitter not shown PART NO DESCRIPTION 633671 Cable Transmitter 633691 Resistor 250 OHM R3 o...

Страница 72: ...64 00 51 25 87 62 2 424 1 270 1500ZPB 1 500 1 200 243 4 NPT 78 00 54 76 80 00 2 974 1 600 1800ZPB 1 800 1 440 292 4 NPT 84 00 60 62 91 88 3 905 2 000 2100ZPB 2 100 1 680 340 4 NPT 84 00 60 62 91 88 4...

Страница 73: ...1302 Goshen Parkway West Chester PA 19380 Phone 610 692 9100 800 888 2323 Fax 610 692 9192 Web www zeks com...

Отзывы: