Safety Measures
OPMI LUMERA® 700
Version 7.3
Page 14
G-30-1673-en
• Check the surgical microscope for sufficient freedom of movement. The
device itself or accessories may be damaged if conflicting with each other.
• When mounting accessories (e.g. fundus viewing systems) on the system,
make sure that sufficient free space is available for focus positioning and
that the surgical microscope cannot touch the patient.
• Before using a fundus viewing system, make sure that the room for move-
ment is larger than the downward travel path of the microscope.
• In order to prevent an unexpected response by the device, check the user
settings of the software before every use.
• The assistant's microscope may swing out of position if you tilt the surgical
microscope to the horizontal viewing direction and the assistant's micro-
scope has not been locked. Adjust the assistant's microscope before use
and make sure it is properly locked in position.
• Always run cables in a manner that will not impede the user's movements.
• Before every use, switch off the light source for light guides that are not
being used and properly attach them on the designated bracket.
• Before every use, check the light source for damages in order to prevent
phototoxic injuries to the patient's eye.
• Before every use, check the filter settings in order to prevent phototoxic
injury to the patient's eye.
• Use the system in the sterile area. Make sure to use the appropriate sterile
accessories for this system.
• Never cover any ventilation openings, as this may e.g. cause the light
source of the system to overheat and fail.
• Never attempt to forcefully connect any electrical connectors (plugs, sock-
ets). If connection is not readily possible, check whether the plug fits the
socket. If any of the connectors are damaged, have Carl Zeiss Service re-
pair them.
• Before using the
wireless
, foot control panel FCP WL ensure its batteries
are fully charged. Inadequate power supply of the
wireless
foot control
panel may lead to malfunctions of the device.
• Go through the checklist in chapter "Operation" (see page 164).
More specific information about the floor stand:
• In order to avoid the device from rolling off inadvertently, use the locking
mechanism on the base of the suspension system and secure the device.
Содержание opmi lumera 700
Страница 1: ...Carl Zeiss OPMI LUMERA 700 User manual G 30 1673 en Version 7 3 2012 05 02...
Страница 4: ...OPMILUMERA 700 Version 7 3 Page 4 G 30 1673 en...
Страница 25: ...Version 7 3 G 30 1673 en Page 25 OPMI LUMERA 700 Safety Measures Fig 1 Safety Equipment 1 4 2 6 7 5 3 8...
Страница 31: ...Version 7 3 G 30 1673 en Page 31 OPMI LUMERA 700 Safety Measures Fig 4 Labels on the microscope 7 5 6 8 1 2 3 4...
Страница 46: ...Safety Measures OPMI LUMERA 700 Version 7 3 Page 46 G 30 1673 en...
Страница 49: ...Version 7 3 G 30 1673 en Page 49 OPMI LUMERA 700 System Overview Fig 17 System overview 6 7 2 1 3 5 4...
Страница 57: ...Version 7 3 G 30 1673 en Page 57 OPMI LUMERA 700 System Overview Fig 21 Components of the surgical microscope 5...
Страница 61: ...Version 7 3 G 30 1673 en Page 61 OPMI LUMERA 700 System Overview Fig 23 Overhead display 11...
Страница 71: ...Version 7 3 G 30 1673 en Page 71 OPMI LUMERA 700 System Overview Fig 29 Controls of XY coupling 1...
Страница 89: ...Version 7 3 G 30 1673 en Page 89 OPMI LUMERA 700 System Overview Fig 39 Display and control panel 1 2 3 1 2...
Страница 103: ...Version 7 3 G 30 1673 en Page 103 OPMI LUMERA 700 System Overview Fig 46 Ports on the 22 TFT 1 2 3 4 5 6...
Страница 106: ...System Overview OPMI LUMERA 700 Version 7 3 Page 106 G 30 1673 en...
Страница 109: ...Version 7 3 G 30 1673 en Page 109 OPMI LUMERA 700 Preparations for use...
Страница 111: ...Version 7 3 G 30 1673 en Page 111 OPMI LUMERA 700 Preparations for use Fig 47 Transport position of the 22 TFT 2 3 1 4...
Страница 113: ...Version 7 3 G 30 1673 en Page 113 OPMI LUMERA 700 Preparations for use Fig 48 OR scene 1 2...
Страница 115: ...Version 7 3 G 30 1673 en Page 115 OPMI LUMERA 700 Preparations for use Fig 49 Connecting the system 2 5 1 3 4...
Страница 137: ...Version 7 3 G 30 1673 en Page 137 OPMI LUMERA 700 Preparations for use Fig 64 Connecting the foot control panel 3 1 2...