background image

 

INTRODUCTION 

Fluar Illuminator Z mot. 

Notes on instrument safety 

Carl Zeiss 

 
 

 

05/2012 

435180-9060-701 

1.2

 

Notes on instrument safety 

 

Fluar Illuminator Z mot. may only be used for the applications described in this operating 

manual. The manufacturer cannot assume any liability for other applications of the instrument, 

including those of individual modules or single parts.  

 

Modifications and repairs to this instrument and any devices operated in combination with the 

microscope must be carried out by our service department or by authorized personnel only. The 
manufacturer accepts no liability for damage caused by unauthorized access to the interior of 

the instrument. Failure to comply with this shall also render any warranty claims invalid. 

 

 

The device may only be operated by instructed personnel. The instruments may only be 

operated by trained personnel who are aware of the possible dangers involved with microscopy 

and the application concerned. The microscope is a high-precision instrument whose 
performance may be impaired if handled improperly. 

 

 

 

The separate manufacturer's instructions must be observed and general safety requirements 
complied with when connecting and operating the HXP 200 C illuminator. 
The HXP 200 C  generates high-energy light with an invisible portion. Risk of dazzling or 

blinding! Never look directly into the light beam or light guide exit. 
The lamp used in the HXP 200 C becomes very hot during operation and has a high internal 

pressure in a heated state. Risk of fire or explosion! 
The lamp must be changed in accordance with the manufacturer's instructions.  
The illuminator may only be connected to a properly installed earthed power outlet. 

 

The mains plug of instruments with a metal housing (e.g. HXP 200 C) may only be connected 

to a socket with earth contact. The protective capacity must not be rendered ineffective by 

using an extension cable without a ground wire. 

 

If it is determined that protective measures are no longer effective, the instrument must be 
switched off and secured against inadvertent operation. Please contact a Zeiss service agency or 

the Carl Zeiss Microscopy Service to repair the instrument. 

 

Dust and dirt may impair the instrument’s performance. The instrument must be effectively 

protected from such influences and covered with the dust cover when not in use. Always check 
whether the instrument is switched off before you cover it. Broad temperature fluctuations, 

direct sunlight and vibrations should be avoided. 

 

 

The instruments are not equipped with special devices to protect against corrosive, potentially 

infectious, toxic, radioactive or other substances that may be hazardous to health. All legal 
regulations must be observed when handling such substances, particularly the relevant national 

accident prevention regulations. 

Содержание Fluar Illuminator Z mot.

Страница 1: ...Operating Manual Fluar Illuminator Z mot for Axio Zoom V16...

Страница 2: ......

Страница 3: ...d a high quality product from Zeiss Before using the instrument the first time please read this operating manual in order to maintain the high quality of the instrument and ensure reliable work with i...

Страница 4: ...ect to updating or revision Unless explicitly authorized dissemination or duplication of this document and commercial exploitation or communication of its contents are not permitted Persons in contrav...

Страница 5: ...General information 13 3 2 Assemble the Fluar Illuminator Z mot and connect it up 13 3 3 Connecting the HXP 200 C illuminator 14 3 4 Loading the reflector turret 15 3 5 Inserting or removing the stop...

Страница 6: ...al devices they are marked with the mark The operating manual contains all information and warnings the operator must comply with The following warning and information symbols are used in this operati...

Страница 7: ...azzling or blinding Never look directly into the light beam or light guide exit The lamp used in the HXP 200 C becomes very hot during operation and has a high internal pressure in a heated state Risk...

Страница 8: ...the possible travel path of the motorized table There is a risk of pinching or injury to the fingers when the table is positioned by the control unit Defective instruments are not to be disposed of as...

Страница 9: ...arts in particular and improper use The instrument manufacturer shall not be liable for damage caused by faulty operation negligence or any other tampering with the instrument particularly the removal...

Страница 10: ...autions and instructions for use must be strictly observed see separate operating manual When operating the microscope always use the anti glare shield to avoid eye damage due to scattered light The c...

Страница 11: ...or modules Manual diaphragm slider 423611 0000 000 Motorized diaphragm slider 423612 9901 000 Choice of reflector modules Z FL P C ACR 435180 9160 000 Z FL P C 435180 9260 000 Z FL P C ACR RW 435180 9...

Страница 12: ...2 4 Technical data Dimensions Fluar Illuminator Z mot length x width x height 31 mm x 277 mm x 92 mm HXP 200 C illuminator width x height x depth 130 mm x 210 mm x 290 mm Weight Fluar Illuminator Z mo...

Страница 13: ...omponents from the packaging and check that all components described on the delivery note are present Remove all shipping braces adhesive tape or similar Keep the original packaging for storage or for...

Страница 14: ...for use at a later date Insert the tube Fig 4 1 into the dovetail mount of the Fluar Illuminator Z mot Fig 4 5 and hand tighten the hexagon socket screw Fig 4 6 with the ball head screwdriver To preve...

Страница 15: ...number is marked on the right hand side of the module mount Fig 5 3 To install or remove reflector modules Fig 5 5 proceed as follows Installing reflector modules Push the reflector module slightly ti...

Страница 16: ...Fluar Illuminator Z mot in the same way However the procedure for removal is different The mounting bay for the diaphragm slider is located on the left hand side of the Fluar Illuminator Z mot Insert...

Страница 17: ...e applications producing optical cross sections through the specimen the ApoTome 2 system can be coupled with the Fluar Illuminator Z mot For this purpose the diaphragm shaft is provided with a specia...

Страница 18: ...the HXP 200 C illuminator Intensity control dial Fig 9 1 Controls light intensity in stages 0 12 5 25 50 and 100 Shutter button remote open Fig 9 2 Button in pressed position open internal shutter of...

Страница 19: ...ch the microscope on by pressing on the HIP After switching on the shutter of the Fluar Illuminator Z mot is always closed Completely open the iris diaphragm of the stop slider man or mot using the co...

Страница 20: ...luminator Z mot Fig 8 1 to open the internal shutter integral LED lights up Select the desired magnification on the microscope and adjust the focus as necessary To protect the specimen or reduce scatt...

Страница 21: ...or description Error cause Remedy No image visible in eyepieces Microscope not switched on Switch on microscope on HIP Reflector turret cover not closed properly Insert cover correctly and close Switc...

Страница 22: ......

Отзывы: