Cable entry knock outs
A
B
C
From
mains
supply
To OF100GIP
Fan terminal
A
B
C
F
D
E
Fuse
L
N
Light Switch
Double Pole
Isolating Switch
SELV BOX
N
L1
L
Light
Earth
Park
Fan
Terminals
3
(24v)
1
(SL)
2
(0v)
3
(24v)
1
(SL)
2
(0v)
• Insert mains cable (A) and clamp using cable clamp provided (B).
• Push the wires into the terminal block (C) as per the wiring diagram (see
section 2.7.6). Tighten the terminal block screws and ensure a good connection.
• Insert low voltage cable through cable entry point (D) and then secure
cable using the cable clamp (E).
• Push the wires into the terminal block (F) as per the wiring diagram (see
section 2.7.6). Tighten the terminal block screws and ensure a good
connection.
• Before fitting the SELV Box Top remove suitable cable knock outs that
best suit the entry position of both the mains and low voltage cables,
ensure that they are dressed and that all sharp edges are removed to
ensure cable insulation is not damaged.
• Fit SELV Cover to SELV Back Plate
and Power Supply and secure using
the 4 off screws provided.
• Insert low voltage cable through
cable entry point (A) and then secure
cable using the cable clamp (B).
• Push the wires into the terminal
block (C) as per the wiring diagram
(see section 2.7.6). Tighten the
terminal block screws and ensure a good connection.
Wiring Diagram
24V DC SELV Model
2.7.6
Fixing Hole