Overview

Greenwood’s OF100GIP is an intermittent or continuously running extract fan,
designed to offer a simplistic approach to meet Building Regulations and provide
an energy efficient domestic ventilation solution to improve indoor air quality in
dwellings. 

The concept revolves around ‘one product’, which has been designed to be 
flexible in application (wall, window and ceiling – 230V / SELV installations) and
to meet the performance requirements of all ‘wet’ rooms within a dwelling. 

Please refer to section 4.0 for how the OF100GIP can be installed. The
OF100GIP features new SMART technology (fully automatic integral delay / 
over-run timer (or run-on timer via pullcord) and humidity functions) which 
monitor the homeowners’ environment. 

Greenwood TimerSMART

TM

monitors the length of time that there is an 

occupancy presence within a wet room (via the ‘Switch Live’) and provides a
fixed over-run time period to best match the length of time that the ‘Switch Live’
is active (as shown in the table below). This removes nuisance running noise and
unnecessary energy wastage typically associated with traditional timers.

Note:

The first 5 minutes will not activate an over-run.

Note:

When the OF100GIP is operated by the pullcord only and has been 

commissioned as a timer, the OF100GIP will operate as follows:

•     Continuous mode: Boost for 15 minutes then automatically return to 

      trickle. Manual override available by re-pulling the pullcord.

•     Intermittent mode: Turn on for 15 minutes then automatically turn off. 

      Manual override available by re-pulling the pullcord.

1.0    General Description / Physical Specification

1.1

1.1.1

1.1.2

1.1.3

         

Time ‘Switch Live’             Continuous Over-run           Intermittent Over-run 

               is Active                          Boost Period                            Period

          0 – 5 minutes                            No over-run                         No over-run

          5 – 10 minutes                          5 minutes                           5 minutes

          10 – 15 minutes                        10 minutes                         10 minutes

          15 – 20 minutes                        15 minutes                         15 minutes

Содержание Omnique OF100GIP

Страница 1: ...Omnique OF100GIP Intermittent Continuous Running Ventilation Installation Instructions ...

Страница 2: ...tructions 6 2 1 General Preparation 6 2 2 Positioning Application 7 2 3 Wall Mounting 8 2 4 Ceiling Mounting 9 2 5 Ducting Guidelines 10 2 6 Electrical 230V 11 2 7 Conversion to SELV 13 3 0 On Site Commissioning Set Up 15 4 0 How Your Fan Can Be Installed 16 5 0 Servicing Maintenance 18 ...

Страница 3: ...within a wet room via the Switch Live and provides a fixed over run time period to best match the length of time that the Switch Live is active as shown in the table below This removes nuisance running noise and unnecessary energy wastage typically associated with traditional timers Note The first 5 minutes will not activate an over run Note When the OF100GIP is operated by the pullcord only and h...

Страница 4: ...e section 2 6 Electrical An alternative boost switch not supplied see section 2 7 Electrical If your fan has been commissioned in intermittent mode the fan can be manually activated by either the pullcord or via the switch live Note If required the pullcord can be removed within wall window installations however the pullcord must be removed within ceiling installations Packaging Includes 1 x OF100...

Страница 5: ...e subject to a direct source of heat in excess of 40 C Observe appropriate safety precautions if working on steps or ladders Wear eye protection when breaking out wall or window materials etc Always isolate fan from mains supply before cleaning Do not use solvents to clean this fan Cleaning and user maintenance shall not be made by children without supervision To disassemble the unit disconnect fr...

Страница 6: ...ent sections Note The grille assembly has been designed to retain and hold the screws and are already in position for final fixing to back plate Note The back plate must be secured using all four fixing points see Section 2 2 2 2 1 2 1 1 2 0 Installation Instructions Decorative Insert Grille Assembly Back Plate ...

Страница 7: ...th the current editions of Building Regulations and BS7671 IEE Wiring Regulations Electrical installation must only be carried out by a qualified Electrician Positioning Application The OF100GIP can be installed on a wall window or ceiling in either location it can be rotated through a 90 angle to accommodate differing installation requirements 2 1 2 2 1 3 2 1 4 2 1 5 2 2 2 2 1 Note In wall window...

Страница 8: ...s Decide on required fan orientation to best suit installation position Ensure that the orientation arrows are facing upwards when in either Portrait or Landscape orientation Cut the duct to width of the plasterboard or tiled wall with slight fall to exterior Make provisions for cable To ensure the fan is in the correct position mount the fan with orientation symbol arrows facing upwards Fill in a...

Страница 9: ...ing clips 3 5 4 Remove grille assembly by unscrewing the four screws located in the four side openings For Ceiling mounted installation remove or cut off pullcord Cut an opening through the ceiling for the fan and electrical cable The unit must be securely mounted using all four fixing holes and fixing screws provided The screw fixings must be completely driven home to ensure that they do not inte...

Страница 10: ...nstall using the least number of fittings to minimise resistance to airflow Where access to ducts will not be possible after construction is complete i e within floor and wall voids consideration should be given to permanent connection and sealing with an appropriate non hardening sealant and not using duct tape to achieve connection and sealing 10 Diagram depicting typical installation ducted thr...

Страница 11: ... 10 000mm2 Electrical WARNING All wiring must conform to BS7671 IEE Wiring Regulations WARNING The appliance must be isolated from the mains supply before removing the electronics cover The installation must be carried out by a qualified electrician The Unity OF100GIP is suitable for 220 240V 50Hz single phase supply fused at 3A SELV 24VDC by using the SELV cover and removable mains power supply A...

Страница 12: ...ble clamp B Push the wires into the terminal block C as per the wiring diagram see section 2 6 10 Tighten the terminal block screws and ensure a good connection Surface Mount Wiring If surface mounted cable is used the corresponding knock outs on both the Grille Assembly and the Back Plate need to be removed to allow cable to enter the product Once cable knock outs are removed ensure that the edge...

Страница 13: ... the SELV Back Plate and Power Supply has been removed the cables that have been unclipped need to be docked into the designated docking point on the Back Plate A SELV Box Installation Install SELV Back Plate and Power Supply in a suitable location outside of the splash zones preferably outside the room where the OF100GIP fan is installed The location should be as such that air can circulate aroun...

Страница 14: ...l block F as per the wiring diagram see section 2 7 6 Tighten the terminal block screws and ensure a good connection Before fitting the SELV Box Top remove suitable cable knock outs that best suit the entry position of both the mains and low voltage cables ensure that they are dressed and that all sharp edges are removed to ensure cable insulation is not damaged Fit SELV Cover to SELV Back Plate a...

Страница 15: ... a slower rate to indicate intermittent mode Press Bathroom or Kitchen button light will go solid High Airflow Boost button will flash factory setting Press speed adjustment buttons to required level and verify with an airflow meter re press Boost button to confirm Low Airflow Trickle button will flash factory setting Press speed adjustment buttons to required level and verify with an airflow mete...

Страница 16: ...run timer on Fan runs for 15 minutes and then automatically turns off Manual override by re pulling the pullcord Switch Live will turn the fan on off Pullcord will not function when fan is activated via Switch Live TimerSMART will activate when Switch Live is turned off Pullcord will not function when the smart timer is activated HumidiSMART will automatically turn the fan on and then off when hum...

Страница 17: ...activated Pullcord turns fan to run timer boost Fan runs at boost 15 minutes and then automatically returns to trickle Manual override by re pulling the pullcord Switch Live will turn the fan to boost trickle Pullcord will not function when fan is activated via Switch Live TimerSMART will activate when Switch Live is turned off Pullcord will not function when TimerSMART is activated TimerSMART wil...

Страница 18: ... do not require lubrication Periodic cleaning of the fan s front cover and casing can be carried out using a soft damp cloth Care must be taken when wiping around the control panel Do not use solvents to clean this fan Please note that your stored fan settings will not be lost during any interruptions to your fan s power supply 5 1 1 5 1 2 5 1 3 5 0 Servicing Maintenance ...

Страница 19: ...etres unless otherwise shown E OE All goods are sold according to Zehnder s Standard Conditions of Sale which are available on request See website for warranty period details Zehnder Group UK Ltd reserves the right to change specifications and prices without prior notice Copyright Zehnder Group UK Ltd 2017 ...

Страница 20: ...oup UK Limited Watchmoor Point Camberley Surrey GU15 3AD Customer Services 44 0 1276 408404 Technical Services 44 0 1276 408402 Email info greenwood co uk Web www greenwood co uk 05 10 945 Issue 2 September 2017 ...

Отзывы: