19 - EN
8. Technical specifications
Description
ComfoFond-L 350
ComfoFond-L 550
Mass ComfoFond-L
42 kg
42 kg
Unit dimensions (l x b x h)
476 x 551 x 760 mm
476 x 551 x 760 mm
Air inlet dimensions
180 mm
180 mm
Air outlet dimensions
160 mm
180 mm
Outside temperature operating area
-22ºC to 45ºC
-22ºC to 45ºC
IP class
44
44
Power supply
220/230V AC, 50/60Hz, 1 phase
220/230V AC, 50/60Hz, 1 phase
Maximum power consumption
0.58 A
0.58 A
Power consumption nominal
0.20 A
0.20 A
Energy consumption maximum *
70 W
70 W
Energy consumption nominal *
46 W
46 W
Energy consumption minimum setting *
5 W
5 W
Heating capacity
1800 W**
2500 W****
Cooling capacity
2000 W***
3000 W*****
Maximum sound capacity
40 dB(A)
40 dB(A)
Ideal brine pressure
1.5 bar
1.5 bar
Brine volume ComfoFond-L
+/- 2 l
+/- 2 l
Brine flow rate
6-8 l/min.
8-10 l/min.
Brine composition
30%-50% ethylene glycol
water mixture
30%-50% ethylene glycol
water mixture
Brine connections
¾” conical male-threaded
¾” conical male-threaded
Pump Class circulation pump
A
A
Maximum head circulation pump
7m
7m
Condensation drain connection
1¼” male-threaded with
32 mm adapter
1¼” male-threaded with
32 mm adapter
Colour
RAL7035
RAL7035
*
Linear adjustment of the energy consumption is possible
** Qv = 350 m3/h, Toutside air = -12 °C, Tbrine flow = 8 °C, vbrine flow = 6 l/min, Tsupply air = 1 °C.
*** Qv = 350 m3/h, Toutside air = 35 °C, Tbrine flow = 12 °C, vbrine flow = 6 l/min, Tsupply air = 25,5 °C.
**** Qv = 550 m3/h, Toutside air = -12 °C, Tbrine flow = 8 °C, vbrine flow = 8 l/min, Tsupply air = 1 °C.
***** Qv = 550 m3/h, Toutside air = 35 °C, Tbrine flow = 12 °C, vbrine flow = 8 l/min, Tsupply air = 25 °C.
8.1
Brine loop dimensions
The ComfoFond-L terrestrial heat collector (recommendations)
Type
Pipe type
Brine volume per 10
metre pipe [l]
Minimum length pipe in
solid ground [m]
Minimum length pipe
in sandy ground [m]
ComfoFond-L 350
25/20.4 PE
3,3
65
130
ComfoFond-L 550
32/26.2 PE
5,3
100
200
8.2
Brine mixture
Desired ethylene glycol percentage
Maximum outside temperature [ºC]
Percentage [%]
-15
35
-20
40
-25
45
-30
50
Higher concentrations of ethylene gly-
col can cause flow-related problems on
account of the viscosity of the mixture.
Irreversible damage will be caused to
the machine if concentrations in excess
of 50% are used.
Содержание ComfoFond-L Series
Страница 4: ...IT IV...
Страница 8: ...IT 4 3 1 Disegno quotato ComfoFond L 350 L 3 2 Disegno quotato ComfoFond L 350 R Vista P Vista P...
Страница 9: ...5 IT 3 3 Disegno quotato ComfoFond L 550 L 3 4 Disegno quotato ComfoFond L 550 R Vista P Vista P...
Страница 31: ...27 IT II Log di manutenzione Data Attivit Sigla...
Страница 34: ...NL IV...
Страница 38: ...NL 4 3 1 Maatschets ComfoFond L 350 L 3 2 Maatschets ComfoFond L 350 R Aanzicht P Aanzicht P...
Страница 39: ...5 NL 3 3 Maatschets ComfoFond L 550 L 3 4 Maatschets ComfoFond L 550 R Aanzicht P Aanzicht P...
Страница 61: ...27 NL II Onderhoud log Datum Activiteit Paraaf...
Страница 64: ...EN IV...
Страница 68: ...EN 4 3 1 Dimensional sketch ComfoFond L 350 L 3 2 Dimensional sketch ComfoFond L 350 R View P View P...
Страница 69: ...5 EN 3 3 Dimensional sketch ComfoFond L 550 L 3 4 Dimensional sketch ComfoFond L 550 R View P View P...
Страница 90: ...EN 26 II Maintenance log Date Activity Initials...
Страница 91: ...27 EN...