5. Maintenance
Disconnect the power supply before carrying out any kind of work on the pump and
protect it against unauthorised reconnection!
Maintenance contains an inspection and a cleaning of the pump housing. For this purpose loosen the
four cross-head screws (pos. 24 of the sectional drawing), remove and clean the inlet filter (pos. 3) and
the base plate (pos. 4). Subsequently, reassemble all parts in the right order.
ATTENTION In case of a worn running wheel (e.g. due to abrasive media) a wear of the mechanical
seal is also possible. The inspection of the mechanical seal and the motor as well as the replacement
of the electric connecting cable should be effected by authorised after-sales services or by
manufacturing factory only.
6. Malfunctions; causes and elimination
- Disconnect the power supply before carrying out any kind of work on the ejection unit!
Failure
Cause
Removal
-
Mains voltage missing or faulty
-
Check power supply
-
Incorrect connection
-
Correct the connection
-
Defective current cable
-
Replacement (after-sales-service)
-
Running wheel is blocked
-
Cleaning
-
Activated motor protection
(overheating, blockage, voltage
failure or other defect)
Check,
inform
the
after-sales-
service
-
Floater got stuck
-
Position the pump in such a way
that the floater can work freely
1. No motor rotation
-
Motor is defective
-
Replacement (after-sales-service)
-
Running wheel is blocked or worn
-
Cleaning/Replacement
-
Pressure pipe is blocked/hose is
bended
-
Clean/remove kinks
2. Motor rotates but does not
convey
-
Intake socket is blocked
-
Clean
3. Discharge flow is too low
-
Pump is not properly bled (air
bubble inside of the housing)
-
Bleed the pressure pipe during
initial commissioning of the pipe, so
that water reaches the pump
housing
4. Discharge flow is too low
-
Too small dimension of the pressure
pipe
-
min. diameter 25 mm (1“)
7. Warranty
As manufacturer, for all pumps of the type series ZPK we provide a warranty of 24 months from date of
purchase. Your sales receipt passes for verification. During that warranty period, we gratuitously
remedy all deficiencies which are attributed to material or fabrication defects by either repairing or
replacing the pump (to our choice).
Defects which are attributed to misuse or wear (running wheel and shaft seal) are excluded from
warranty.
Furthermore, the warranty claim expires if works (excepting those under point 5) are effected on the
pump. We will assume no responsibility for consequential damages that are caused by a breakdown of
the pump.
Содержание S-ZPK Series
Страница 9: ...9 11 Schnittzeichnung und Ersatzteilliste ZPK 30 A ZPK 35 A...
Страница 11: ...11 12 Schnittzeichnung und Ersatzteilliste ZPK 40 A...
Страница 20: ...20 11 Sectional drawing and spare parts list ZPK 30 A ZPK 35 A...
Страница 22: ...22 12 Sectional drawing and spare parts list ZPK 40 A...
Страница 31: ...31 11 Sch ma de coupe et liste des pi ces d tach es ZPK 30 A ZPK 35 A...
Страница 33: ...33 12 Sch ma de coupe et liste des pi ces d tach es ZPK 40 A...