background image

 

 

- 7 -

10. 

QUICK SHIFT 

 

 

Enter 

Set Ign. 

menu and move to 

Quick Shift  

with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

...you entered submenu 

Quick Shift

.  

 

Submenu organisation: 

Shift Kill Time 

- basic kill time (at 12000rpm) 

Smart Shift   

- activating/deactivating automatic kill time for different revs 

Exit 

 

 

- exit submenu 

 
 

10.1.  SHIFT KILL TIME 
 

 

Enter 

Quich Shift 

 menu and move to 

Shift Kill Time 

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 

Set kill time with pressing 

'

+

'

, or 

'

-

'

 (in 1ms steps) and press 

'

ENTER

'

 to confirm. 

 
 

10.2.  SMART SHIFT 

 
Smart shift function automatically adjusts kill time for different revs. Shift kill time must 
be always set, as basic kill time.  
 

 

Enter 

Quich Shift 

 menu and move to 

Smart Shift 

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 

Enable, or disable 

Smart Shift

 function with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to 

confirm. 

 

 

11. 

REV LIMIT 

 

 

Enter 

Set Ign. 

menu and move to 

Rev Limit 

with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 

to confirm. 

 

Set 

Rev Limit

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 

 

12. 

STATIC ANGLE 

 

Static angle is reference point for CDI unit. Correct static angle is very important for 
correct ignition advance. If programmed static angle is not same as mechanical position 
of pickup(trigger point), then ignition advance will not be correct. Too much difference 
will result in bad running engine, or even non operational engine. Ignition is always after 
static angle(trigger point)...that means that static angle must be always greater than 
maximum ignition advance. 
 

 

Enter 

Set Ign. 

menu and move to 

Static Angle 

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 

Set static angle with pressing 

'

+

'

, or 

'

-

'

 (in 0.1deg steps) and press 

'

ENTER

'

 to confirm. 

 

Содержание PDCI-NS1V

Страница 1: ...t light and power jet output 5 Amp constant spark energy from idle to 13000 RPM 50mJ Important Circuit is fully protected against reverse polarity from firmware 31 170203 Features fast power up also s...

Страница 2: ...es Danger of electric shock Avoid connecting PDCI to 12V power supply before connecting to ignition coil High voltage is generated and touching free wires can cause electric shock or damage the unit 1...

Страница 3: ...V PARAMETERS SUBMENU Load PV Curve load select PV curve Save PV Curve save new PV curve Set PV Curve PV curve parameters submenu Deviation deviation of PV position Close Position max close PV position...

Страница 4: ...g processing don t make unreasonable curve course Every time you make any changes to ignition curve it is automatically saved to position 0 Later you can save it to any other position 1 or 2 Curve Exa...

Страница 5: ...can save it to any other number 1 or 2 Ignition Map Example 5 2 Change NUMBER OF IGNITION CURVE POINTS Move to Nr of Points with pressing or and press ENTER to confirm Select number of ignition point...

Страница 6: ...ded With Advance 1 0 0deg ignition map is unchanged Enter Set Ign menu and move to Advance 1 with pressing or and press ENTER to confirm Set advance with pressing or in 0 1deg steps and press ENTER to...

Страница 7: ...ENTER to confirm Enable or disable Smart Shift function with pressing or and press ENTER to confirm 11 REV LIMIT Enter Set Ign menu and move to Rev Limit with pressing or and press ENTER to confirm S...

Страница 8: ...atic angle just to have starting point look at drawing below Anticlockwise rotation TRIGGER POINT TDC static angle Clockwise rotation TDC TRIGGER POINT static angle program CDI with measured approxima...

Страница 9: ...n the rotor and stator Result of above procedure is very accurate static angle 13 COMPENSATION It is compensation of signal delay from pickup to spark plugs You can check this delay with stroboscope l...

Страница 10: ...if TPS enabled Three duty cycle curves for different throttle positions can be programmed Each curve can be programmed in 8 rev points Enter Power Jets menu and move to set Power Jet 1 with pressing o...

Страница 11: ...imum open position and confirm calibrating with pressing ENTER or exit calibration with pressing Displayed number should be between 500 and 1010 18 TCT mode Throttle Close spark Termination mode reduc...

Страница 12: ...to confirm Change Stop SW Mode with pressing or and press ENTER to confirm 22 Tach Ratio Tachometer output pulse ratio can be set to 1 or 2 pulses per revolution Enter Set Ign menu and move to Tach Ra...

Страница 13: ...oint Exit exit submenu Important To avoid wrong processing don t make unreasonable curve course Every time you make any changes to PV curve it is automatically saved to number 0 Later you can save it...

Страница 14: ...sition with pressing or and press ENTER to confirm 27 Open Position Max open position must be calibrated Max open position is when curve is set to 100 Open position can be moved to any desired positio...

Страница 15: ...mation displayed on the programmer is software version With programmer you can watch revs calculated advance ignition angle TPS position depends on setting in the menu Information You can connect or d...

Отзывы: