- 2 -

- each curve can be set in 4 to 15 curve points 
- 3D interpolated ignition map, if TPS selected 
- signal delay compensation 
- instant monitoring of rev's and angle, via LCD(hand held programmer) 
- programmable power valve actuation 
- store and load function for 8 PV curves 
- external switch for changing PV curve while riding 
- programmable PV deviation 
- programmable max close and max open positions 
- self PV test on power-up 
- PV error detecting (position sensor failure, servo motor failure)  
- fast processing for high accuracy - delays from 1us 
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)

 

 
Very important! 

Resistor  spark  plugs  must  be  used,  because  they  produce  less  electromagnetic 
disturbances. 
 

Danger of electric shock! 

Avoid  connecting  PDCI  to  12V  power  supply,  before  connecting  to  ignition  coil.  High 
voltage is generated and touching free wires can cause electric shock, or damage the 
unit. 
 

 

 

1. 

HOW TO ENTER MENU

 

 

 

Connect 

programmer

 to 

PDCI

 and wait few seconds for activation of 

programmer 

and 

press 

'

ENTER

'

 

Move through menu with pressing 

'

+

'

, or 

'

-

'

 and select with pressing 

'

ENTER

'

.  

 

Exit menu with selecting 

Exit.

  

 
 

2. 

MENU ORGANIZATION  

 

Set Ign. 

 

- ignition parameters submenu 

Set PV  

 

- PV parameters submenu 

Exit 

 
 

2.1. 

SET IGNITION PARAMETERS SUBMENU 

 

 

Load Ign. Map

 

- load (select) ignition map  

Save Ign. Map

 

- save new ignition map 

   

Set Ignition Map

 

- ignition map parameters submenu 

Advance 

 

- advance/retard whole ignition map on both ignition coil outputs 

Advance 1 

 

- advance/retard ignition coil output 1 

Advance 2 

 

- advance/retard ignition coil output 2 

Gear Shift Light 

- shift light 

Quick Shift   

- quick shift settings  

Содержание PDCI-NS1V

Страница 1: ...t light and power jet output 5 Amp constant spark energy from idle to 13000 RPM 50mJ Important Circuit is fully protected against reverse polarity from firmware 31 170203 Features fast power up also s...

Страница 2: ...es Danger of electric shock Avoid connecting PDCI to 12V power supply before connecting to ignition coil High voltage is generated and touching free wires can cause electric shock or damage the unit 1...

Страница 3: ...V PARAMETERS SUBMENU Load PV Curve load select PV curve Save PV Curve save new PV curve Set PV Curve PV curve parameters submenu Deviation deviation of PV position Close Position max close PV position...

Страница 4: ...g processing don t make unreasonable curve course Every time you make any changes to ignition curve it is automatically saved to position 0 Later you can save it to any other position 1 or 2 Curve Exa...

Страница 5: ...can save it to any other number 1 or 2 Ignition Map Example 5 2 Change NUMBER OF IGNITION CURVE POINTS Move to Nr of Points with pressing or and press ENTER to confirm Select number of ignition point...

Страница 6: ...ded With Advance 1 0 0deg ignition map is unchanged Enter Set Ign menu and move to Advance 1 with pressing or and press ENTER to confirm Set advance with pressing or in 0 1deg steps and press ENTER to...

Страница 7: ...ENTER to confirm Enable or disable Smart Shift function with pressing or and press ENTER to confirm 11 REV LIMIT Enter Set Ign menu and move to Rev Limit with pressing or and press ENTER to confirm S...

Страница 8: ...atic angle just to have starting point look at drawing below Anticlockwise rotation TRIGGER POINT TDC static angle Clockwise rotation TDC TRIGGER POINT static angle program CDI with measured approxima...

Страница 9: ...n the rotor and stator Result of above procedure is very accurate static angle 13 COMPENSATION It is compensation of signal delay from pickup to spark plugs You can check this delay with stroboscope l...

Страница 10: ...if TPS enabled Three duty cycle curves for different throttle positions can be programmed Each curve can be programmed in 8 rev points Enter Power Jets menu and move to set Power Jet 1 with pressing o...

Страница 11: ...imum open position and confirm calibrating with pressing ENTER or exit calibration with pressing Displayed number should be between 500 and 1010 18 TCT mode Throttle Close spark Termination mode reduc...

Страница 12: ...to confirm Change Stop SW Mode with pressing or and press ENTER to confirm 22 Tach Ratio Tachometer output pulse ratio can be set to 1 or 2 pulses per revolution Enter Set Ign menu and move to Tach Ra...

Страница 13: ...oint Exit exit submenu Important To avoid wrong processing don t make unreasonable curve course Every time you make any changes to PV curve it is automatically saved to number 0 Later you can save it...

Страница 14: ...sition with pressing or and press ENTER to confirm 27 Open Position Max open position must be calibrated Max open position is when curve is set to 100 Open position can be moved to any desired positio...

Страница 15: ...mation displayed on the programmer is software version With programmer you can watch revs calculated advance ignition angle TPS position depends on setting in the menu Information You can connect or d...

Отзывы: