20. 

Trigger Mode 

 

  Select trigger mode for specific engine. 
 

Trigger Mode

 '1' is for RS250 NF5 and NSR250 MC21 

 

Trigger Mode

 '2' is for RS250 NX5 

  

 

Enter 

Set Ign. 

menu and move to 

Trigger Mode 

with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 

Change 

Trigger Mode

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm. 

 
 

21. 

Stop Switch Mode

 

 
It defines stop switch position for engine stop.  
"

Low Level Stop

" ... engine stops at low level signal (when stop switch connected to 

the ground). 
"

High Level Stop

" ... engine stops at high level signal (when stop switch is opened). 

 

 

Enter 

Set Ign.

 menu and move to 

Stop SW Mode 

with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm.  

 

Change 

Stop SW Mode

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm.

 

 

 

22. 

Tach Ratio

 

 

Tachometer output pulse ratio can be set to 1, or 2 pulses per revolution. 

 

 

Enter 

Set Ign.

 menu and move to 

Tach Ratio 

with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 

to confirm.  

 

Change 

Tach Ratio

 with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 to confirm.

 

 

 

23. 

Ignition Test 

 

Spark execution test without running engine. Spark can be optically checked, with 
removed spark plug connected to plug cup and to the ground. 
 
Enter 

Set Ign. 

menu and move to 

Ignition Test 

 with pressing 

'

+

'

, or 

'

-

'

. With pressing   

'

ENTER

'

  multiple sparks will occur, for about 1s separately on each cylinder.  

 

 

24. 

Load PV Curve 

 

 

Enter 

Set PV

 

menu and move to 

Load PV Curve 

with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

'

 

Select number of previously saved ignition curve, with pressing 

'

+

'

, or 

'

-

'

 and press 

'

ENTER

to confirm. 

 
 

Содержание PDCI-NS1V

Страница 1: ...t light and power jet output 5 Amp constant spark energy from idle to 13000 RPM 50mJ Important Circuit is fully protected against reverse polarity from firmware 31 170203 Features fast power up also s...

Страница 2: ...es Danger of electric shock Avoid connecting PDCI to 12V power supply before connecting to ignition coil High voltage is generated and touching free wires can cause electric shock or damage the unit 1...

Страница 3: ...V PARAMETERS SUBMENU Load PV Curve load select PV curve Save PV Curve save new PV curve Set PV Curve PV curve parameters submenu Deviation deviation of PV position Close Position max close PV position...

Страница 4: ...g processing don t make unreasonable curve course Every time you make any changes to ignition curve it is automatically saved to position 0 Later you can save it to any other position 1 or 2 Curve Exa...

Страница 5: ...can save it to any other number 1 or 2 Ignition Map Example 5 2 Change NUMBER OF IGNITION CURVE POINTS Move to Nr of Points with pressing or and press ENTER to confirm Select number of ignition point...

Страница 6: ...ded With Advance 1 0 0deg ignition map is unchanged Enter Set Ign menu and move to Advance 1 with pressing or and press ENTER to confirm Set advance with pressing or in 0 1deg steps and press ENTER to...

Страница 7: ...ENTER to confirm Enable or disable Smart Shift function with pressing or and press ENTER to confirm 11 REV LIMIT Enter Set Ign menu and move to Rev Limit with pressing or and press ENTER to confirm S...

Страница 8: ...atic angle just to have starting point look at drawing below Anticlockwise rotation TRIGGER POINT TDC static angle Clockwise rotation TDC TRIGGER POINT static angle program CDI with measured approxima...

Страница 9: ...n the rotor and stator Result of above procedure is very accurate static angle 13 COMPENSATION It is compensation of signal delay from pickup to spark plugs You can check this delay with stroboscope l...

Страница 10: ...if TPS enabled Three duty cycle curves for different throttle positions can be programmed Each curve can be programmed in 8 rev points Enter Power Jets menu and move to set Power Jet 1 with pressing o...

Страница 11: ...imum open position and confirm calibrating with pressing ENTER or exit calibration with pressing Displayed number should be between 500 and 1010 18 TCT mode Throttle Close spark Termination mode reduc...

Страница 12: ...to confirm Change Stop SW Mode with pressing or and press ENTER to confirm 22 Tach Ratio Tachometer output pulse ratio can be set to 1 or 2 pulses per revolution Enter Set Ign menu and move to Tach Ra...

Страница 13: ...oint Exit exit submenu Important To avoid wrong processing don t make unreasonable curve course Every time you make any changes to PV curve it is automatically saved to number 0 Later you can save it...

Страница 14: ...sition with pressing or and press ENTER to confirm 27 Open Position Max open position must be calibrated Max open position is when curve is set to 100 Open position can be moved to any desired positio...

Страница 15: ...mation displayed on the programmer is software version With programmer you can watch revs calculated advance ignition angle TPS position depends on setting in the menu Information You can connect or d...

Отзывы: