9- TROUBLESHOOTING
CHECKS
A- Check that the motor is powered.
B- Check the presence of all the phases for
the three-phase motors.
C- Check that the pump is not dry running.
A- Check that the power supply voltage
corresponds to the rated voltage.
B- Check the presence of all the phases.
C- Check the setting of the protection and the
presence of possible open or dirty contacts.
D- Check that the temperature of the liquid is
not too high.
E- Check for the presence of excess friction
(scraping between rotating and fixed parts,
pump clogged by sand, etc.).
A- Check that all the phases are present and
that the voltage is sufficient.
B- Check for the presence of excess friction
(scraping between rotating and fixed parts,
pump clogged by sand, etc.).
A- Check correct rotation direction in the
three-phase versions.
B- Check that the pipes are not partially
clogged or leaking.
C- Check that the flow rate of the pump is
below that of the well.
D- Check wear on the pump.
A- Check that the level of the well has not
dropped excessively with consequent possible
dry operation.
B- Check that the head required is not higher
than the one of the pump.
C- Check correct rotation direction in the
three-phase versions.
D- Pump obstructed by impurities.
A- Check for leaks in the system.
B- Check correct operation of the non-return
valve.
C- Check efficiency of the pressure switch, if
used.
D- Check that the tank is sufficiently sized.
E- Check positioning of the probes protecting
against dry operation, if used.
PROBLEM
1- The motor does not start
or the pump does not deliver
water.
2- The motor protection cuts
soon after start.
3- The motor protection
cuts after long periods of
operation.
4- The motor rotates but the
flow rate or pressure are not
sufficient.
5- The motor rotates but
does not deliver water.
6-The pump starts and stops
too frequently.
SOLUTIONS
A- Check the fuses or re set the
switch.
B-Restore the missing phase.
C- Wait for the level of the well
to be restored naturally.
B- Restore the missing phase.
C- Restore the protections,
consulting the rating plate
specifications or replacing the
components involved.
E- Eliminate the cause of the
friction or remove any
obstructions from the pump.
A- Restore the missing phase.
B- Eliminate the cause of the
friction or remove any
obstructions from the pump.
A- lnvert any two phase leads.
B- Eliminate the obstructions or
leaks.
C- Replace the pump with one
with a lower flow rate.
D- Service the pump.
A- Wait for the natural level to be
restored or lower the level of the
well. Install adequate protection
against dry operation.
B- Replace the pump with one
having suitable characteristics.
C- lnvert two phase leads.
D- Clean the pump, filter and pipes.
A- Eliminate the leaks.
B- Repair or replace the valve.
C- Repair or replace the pressure
switch.
D- Replace it with one of adequate
capacity.
E- Reposition the probes to obtain
longer operating periods.
Содержание P H3 Series
Страница 2: ......
Страница 4: ...3 Fig 1 Fig 2 Fig 3 2 7 9 1 2 4 4 5 6 3 10 3 4 6 7 9 9 8 3 m 10 m 1 5 m 1 5 2 5 11 Fig 4...
Страница 5: ...4 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 V Hz...
Страница 6: ...5 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 Q 0 6 2 4 m3 h H 144 48 m...
Страница 51: ...GB D F I E PL HR MNE RO SRB RUS 50 8 9 B C B C D B C D B C D B D 1 2 3 4 5 6 B C B C B B C D B C D B C D...
Страница 55: ...GB D F I E PL HR MNE RO SRB BG 54 8 9 A 1 2 3 4 5 6 A...
Страница 58: ...NOTES...
Страница 59: ......