Operation manual of ZBL-R800, ZBL-R630, ZBL-C310A
Hotline: (86)010-51290405 Fax: (86)010-51290406
25
it(setting non-zero value), if cover thickness of tested rebar is below
the set value, the detector will warning danger, and do not present and
store the tested thickness.
Pressing
【
a
】
,
【
b
】
in figure 3-7 to shift cursor to Minimum, then
press
【
ENTER
】
to set the minimum thickness, pressing
【
a
】
or
【
b
】
for once can increase or decrease by one and long time
pressing of these two keys, the value increase or decrease
consecutively. After it is done, pressing the
【
SAVE
】
or
【
ENTER
】
,
cursor will disappear and go back to parameter setting interface as
shown in figure 3-7.
Attention: When the minimum thickness is setting to 0, the
warning alarm will be closed.
6. Data
correction
In order to lower the effects for the measurement of cover thickness of
tested rebar by adjacent abreast ones, it is better to set center distance
from adjacent rebar to tested rebar. The detector modifies test result
automatically and improve test accurately. It is divided into “Manual”
and “None”. After starting, the default one is “None”—no correction.
While “Manual” means modifying based on center distance of
adjacent rebars set manually and displays the measured results after
correction.
Pressing
【
a
】
,
【
b
】
in figure 3-7 to shift cursor to Corr., then press
【
ENTER
】
to set the correction mode, pressing
【
a
】
and
【
b
】
can achieve shift between “Manual” and “None”. If “Manual” is
selected, inputable option is present on the right side and the range is
50-110mm. Pressing
【
`
】
key can move cursor to digit, and
【
a
】
or
【
b
】
for once can increase or decrease by one and long time
pressing of these two keys, the value increase or decrease
consecutively. After it is done, pressing the
【
SAVE
】
or
【
ENTER
】
,
cursor will disappear and go back to parameter setting interface as