Before you disassembling the valve the following steps must be done:
• Wash the valve with water
• Discharge the pressure from the supply system
Then proceed as follows:
6.4
Valve disassembly
*Use silicon-based grease or oil specific for O-rings. For any questions or
information contact the Zator company.
Unscrew the coil connector screw;
Unscrew the micrometric adjustment
with a 13mm wrench, then pull it out
(don’t operate on the adjustment
handle);
Then pull out the coil connector;
1
3
2
13
Check the wear of the micrometric
adjustment O-ring and if it is
necessary, replace it. Always grease*
the new O-rings before assembling
them;
4