USER AND MAINTENANCE MANUAL
28
ELECTROMAGNETIC VALVE
DLK22LV
*Use silicon-based grease or oil specific for O-rings. For any
questions or information contact the Zator company.
Check the wear of the O-ring inside
the valve body and if it is necessary,
replace it. Always grease* the new
O-rings before assembling them;
Unscrew the nozzle with a 10mm
wrench by holding the guide sleeve
with a 15mm wrench;
Unscrew the guide sleeve with a
15mm wrench, then pull it out from
the valve, being careful not to drop
the coil on the ground because it will
be free to move;
Pull out the needle using fingers (to
disassemble the needle see section
6.5 - Needle disassembly);
Remove the coil from the valve body;
9
5
7
6
8
10
15
15
Содержание DLK22LV
Страница 1: ...DLK22LV elettromagnetic valve USERAND MAINTENANCE MANUAL gluing solutions...
Страница 6: ......
Страница 7: ...USERAND MAINTENANCEMANUAL elettromagnetic valve DLK22LV...
Страница 37: ...SECTION 10 DIMENSIONS 37 Zator Via Galvani 11 20095 Cusano Milanino MI Italia www zator it info zator it NOTE...
Страница 38: ...38 USER AND MAINTENANCE MANUAL ELECTROMAGNETIC VALVE DLK22LV...
Страница 39: ......