CAUTION: the trouble shooting must be performed only by qualified personnel observing
the safety norms.
TROUBLE
POSSIBLE CAUSE
WHAT TO DO
No or little quantity
of dispensed fluid
The valve doesn’t receive any
signal
• Check the cables of the valve, the start sensor
and the encoder;
• Check the functioning data setted on the control;
• Make a manual test
The pressure of the fluid is low
or missing
Check the supply pressure
The nozzle is clogged
Unscrew and clean the nozzle
The filter is dirty
(If in use)
Wash or replace the filter
Bent pipe
Check the condition of the supply pipe
Residual glue into the system
Wash the complete system
Leak of fluid from the
adjustment
Adjustment O-ring is damaged
Replace the adjustment O-ring
Leak of fluid from the
top of the coil
O-ring inside the valve body is
damaged
Replace the O-ring inside the valve body
Nozzle drips fluid
even if the valve is
not activated
Presence of dirt inside the
nozzle
Clean or replace the nozzle
The valve is activated
with a lag
The needle spring is deteriorated Replace the needle spring
7
TROUBLE SHOOTING
Содержание DLK22LV
Страница 1: ...DLK22LV elettromagnetic valve USERAND MAINTENANCE MANUAL gluing solutions...
Страница 6: ......
Страница 7: ...USERAND MAINTENANCEMANUAL elettromagnetic valve DLK22LV...
Страница 37: ...SECTION 10 DIMENSIONS 37 Zator Via Galvani 11 20095 Cusano Milanino MI Italia www zator it info zator it NOTE...
Страница 38: ...38 USER AND MAINTENANCE MANUAL ELECTROMAGNETIC VALVE DLK22LV...
Страница 39: ......