Page – 30/75
AFMNA0AA – EPS-BLI HYG – User Manual
25) SINP2 PEAK S
Not used.
26) ENC SENS OFF. S
(Factory adjusted). This adjustment defines the difference between the magnetic
rotation sensor and the electrical zero of the motor for the supervisor
microcontroller.
9.2.3
SET MODEL list
This menu is implemented in the Zapi hand set to make possible the remote connection
but it is not implemented in the PC CAN Console. To enter and navigate the SET
MODEL list by the Zapi hand set go down the following procedure.
Opening Zapi lines.
EPSHTM 6U NAx.xx
24 V 50 A 00000
Press ROLL UP + SET UP simultaneously to enter
CONFIG MENU.
% ' %
' ' '
The display will show: SET MODEL.
CONFIG MENU
SET MODEL
Press ENTER to go into the SET MODEL menu.
' % '
' ' '
The display will show the first option.
MODEL TYPE
0
Press ROLL UP or ROLL DOWN to scroll the
parameters.
% ' '
% ' '
The display will show the desired parameter and its
actual setting.
CONNECTED TO
6
Press SET UP or SET DOWN to modify the setting.
' ' %
' ' %
The display will show the new setting.
CONNECTED TO
2
Press OUT to exit the menu.
' ' '
' % '
The display will ask “ARE YOU SURE?”.
ARE YOU SURE?
YES=ENTER NO=OUT
Press ENTER for yes, OUT for no.
' % '
' ' '
' ' '
' % '
The display will show: SET MODEL.
CONFIG MENU
SET MODEL
Press OUT again. Display will show the opening
Zapi lines.
' ' '
' % '