50
Mod. NARA PL. 24-34 rev 01
Instructions for use
translated from the original text
IT
IT
FR
FR
ES
ES
EN
EN
-Other messages:
Sond
Temperature Probe status display.
The message is displayed during the Check-Up
phase and indicates that the temperature read
on one or more of the probes is equal to the mini-
mum or maximum value depending on the probe
in question. Check that the probes are not open
(reading of the minimum value on the tempera-
ture scale) or have been short-circuited (reading
of the maximum value on the temperature scale).
Service
Message to indicate that the programmed opera-
tional hours have been reached. You are required
to call the Assistance Service.
Clean
Message to indicate that the programmed opera-
tional hours have been reached. You are required
to clean the stove or boiler.
Block
Message that appears if the system is switched
off in a non-manual manner during the Switch-
on phase (after Pre-loading): the system will only
switch off once operation is steady.
Er20
Grille Sensor closed
Port
Door open
Er06
Pellet Thermostat open
Link Er-
ror
Lack of communication between the keypad and
control board
4.2.2
HOW TO USE THE MENUS
The first menu screen, comprising of the user menu, is displa-
yed through the pressing of key p3.
By using keys p4 and p6, you can select the desired option.
Key p3 may be used to enter the selected sub-menu, thus
obtaining a list of the sub-menus or the setting of the selected
parameter.
Auger calibration
Max: 5
Set: 0
Min: -5
Pellet power
Auger calibration
Fan calibration
Combustion management
Heating management
Chrono
Manual load
Reset Service
The settings menu consists of the parameter name (first and
second line), the minimum and maximum value and the cur-
rent “set” value
The “set” field can be modified using the p4 key (increase) and
the p6 key (decrease)
Use the p3 key to memorise the set value. With p1, the opera-
tion is deleted and the previous value is restored
User menu
Press p3 to access the settings menu. The menu is as follows:
MENU
DESCRIZIONE
C o m b u -
stion mana-
gement *
Pellet po-
wer
It allows you to modify the
system’s combustion Power in
Pellet operational mode
Auger cali-
bration
Menu to modify the work time
or the Auger speed
Fan cali-
bration
Menu to modify the Combu-
stion Fan speed
Auger calibration
Max: 5
Set: 0
Min: -5
parameter name
maximum settable
current value
minimum settable
Содержание NARA PLUS 24
Страница 2: ......
Страница 32: ......
Страница 62: ......
Страница 67: ......
Страница 68: ...Mod NARA PLUS 24 34 rev 01...