Refrigeration unit
Series Zero Direct-Drive
Z200 | Z250 | Z350 | Z380
Z380 Multi
INSTALLATION MANUAL
rev.01
71
3.19 Single temperature heating kit (optional)
3.19.1 Operating logic
This option allows the unit to have two functions:
a)
Cooling
mode: inject liquid into the suction line to reduce the temperature of the compressor
exhaust gas.
b)
Heating
mode: it pushes most refrigerant from the condenser and the liquid receiver to the
evaporator. This establishes a higher pressure and temperature during heating mode, increasing
performance and efficiency.
Figure 77 - Heating kit
3.19.2 Components
•
Liquid injection solenoid assembly
•
Reel
•
Plugs and connectors for assembling and connecting new parts
•
Thermostat
•
PMX/1 pressure switch
•
Diode D/1
3.19.3 Installation
Follow the instructions in the installation manual OIST061 for assembly.