Motor not running
Improperly wired
Check wiring against diagram
Low line voltage
Check line voltage, determine
location of voltage drop
Relay contacts not closing
Check by operating manually.
Replace relay
Fuses Blown
Replace
Open circuit in motor winding Check terminal leads
High-pressure cut-out open
Eliminate cause of excessive
pressure 1.1.6 & Section 4
Motor faulty
Replace compressor
Unit Short cycle
Shortage of refrigerant
Repair leak and recharge
Restricted expansion valve
Clean expansion valve
Refrigerant overcharge (high-
pressure cut-out)
Remove excess of charge
Cycling on high-pressure cut-
out
Check air flow and fan
Dirty condenser coil
Clean coil
Unit operates long or
continuously
Shortage of refrigerant
Repair leak and recharge 4.4
Thermostat faulty
Repair or replace
Dirty condenser
Clean condenser 4.17
Air in the system
Evacuate and recharge system 4.3
4.5 4.6
Compressor inefficient
Replace compressor
Plugged expansion valve
Clean expansion valve
Iced or plugged coil
Defrost or clean coil
Defective vehicle body
insulation
Correct or replace
Too many door openings
Keep door closed, install plastic
curtains
Load too warm
Pre-cool hot product
Excessive superheat at
expansion valve
Adjust superheat 4.15.1
Box Temperature too high
Refrigerant Shortage
Repair leak and recharge
Thermostat set point too high Change set point
Expansion valve plugged
Clean or replace
Restricted lines
Clean restriction. Tubing pinched
or shut
Hot load
Precool hot product
Expansion valve superheat
too high or too low
Adjust superheat