5.2 TROUBLESHOOTING BY SYMPTOM
Symptom
Possible Causes
Remedy
Unit not cooling
Shortage of refrigerant
4.4
Defrost cycle not terminated 4.16
Abnormal pressure
4.8 & 6
Hot gas solenoid valve
malfunction
4.12
Evaporator needs defrosting
Expansion valve bulb
improperly mounted
4.14
Expansion valve bulb making
poor contact
4.14
Expansion valve open too
much (too low superheat)
4.14
Expansion valve closed too
much (too low superheat)
4.14
Expansion valve capillary
eroded or leaking
4.14
Expansion valve partially
closed by ice or dirt
4.14
Restricted dryer
4.9
Evaporator fan not operating Check voltage
Compressor
Broken compressor belt
Too much oil 4.11.5
Broken valve plate
Liquid slugging
Compressor drive clutch defective
Defrost malfunction
Automatic defrost not
initiating
Defrost thermostat open or
defective
Hot gas solenoid valve malfunction
(4.12)
Defrost disabled by cab command
(3.6)
Manual defrost not initiating Microprocessor defective or
temperature not low enough for
initiation.
Defrost cycle initiates but
does not defrost
Hot gas solenoid valve malfunction
4.12
Frequent defrost
Wet load
Defrost setting too low 3.6 & 7
Unit not defrosting
Shortage of refrigerant
Hot gas solenoid valve malfunction
Bad electrical connections