TASK IN 1 / TASK IN 2 COMMAND

TASK IN1

 <LO/HI> 

RELAY1 

<ON/OFF> 

or

 TASK IN2

 <LO/HI> 

RELAY2 

<ON/OFF>

TASK IN1

 <LO/HI> 

RELAY1 TIME 

<t1> 

or

 TASK IN2

 <LO/HI>

 RELAY2 TIME

 <t2>

TASK IN1

 <LO/HI> 

NONE

 

or

 TASK IN2 

<LO/HI>

 NONE

KEYWORDS

TASKI IN1/TASK IN2

 – defines the output the configuration refers to.

RELAY1/RELAY2

 – defines the output that must be activated after a given status occurance in the input 

TIME

 – defines that after an occurrence of the <LO/HI> status in IN1 / IN2 input, the OUT1/OUT2 output changes its status for a time 

limited by <t1> <t2> parameters.

NONE – defines that after an occurrence of the <LO/HI> status in IN1 / IN2 input, the GRM-10 device avoids the status (it does not re-

spond).

PARAMETERS

<LO/HI>  A parameter for the keyword TASK IN1/TASK IN2 defining the level of the input IN1/IN2 that activates a specific output oc-

currence. The normal status of the IN1/IN2 inputs is the high state HI. The low status is achieved by linking the selected input 

to terminal C.

<ON/OFF>  A parameter for the RELAY1/RELAY2 keyword - it defines the output status:

ON - the output is on.

OFF - the output is off.

<t1>  Time [s] of the OUT1 / OUT2 output after a defined status occurred in IN1 input. This parameter is configured in the range of 

1 to 3600.

<t2>  Time [s] of the OUT1 / OUT2 output after a defined status occurred in IN1 input. This parameter is configured in the range of 

1 to 3600.

CLIP or TEXT MESSAGE control have a higher priority than inputs. It means that if a specific status occurs in IN1/IN2 inputs, the OUT1 

/OUT2 output is switched on permanently or only for <t1>/<t2> time. It can be switched off by means of a CLIP or a TEXT MESSAGE 

any time. 
In case of MEM parameter adjustment (in RELAY1 / RELAY2 configuration commands) for a selected output, the adjustment remembered 

for inputs in the time mode is the status before activation of the <t1>/<t2>.

TASK IN1

 <LO/HI> 

NONE

 

MESSAGE

 <text message content up to 30 signs>

TASK IN2

 <LO/HI> 

NONE

 

MESSAGE

 <text message content up to 30 signs>

MESSAGE

 A keyword - it defines the text message content to be sent by the GRM-10 device to its receivers. Their telephone numbers 

are configured in the INFO command. The text message can include up to 30 signs. The occurrence of a specific status <LO/

HI> in the input results in sending a text message.

TASK INx 

<LO/HI>

 RELAYx 

<ON/OFF/TIME> <tx>

 MESSAGE 

<text message content up to 30 signs>

The command makes the connection between the specific status occurrence (LO/HI) in the IN1/IN2 input with an appropriate activation 

of the OUT1 / OUT2 output and sending a text message (MESSAGE) with a defined content..

X  number of an input / output

1  input /output IN1/OUT1

2  input /output IN2/OUT2

<tx>  f the output must be active for a period of time (TIME), then the parameter defines time for the time mode. This parameter is config-

ured in the range of 1 to 3600.

Examples of commands:

Command

Description

TASK IN1 LO RELAY1 ON

After LO status appears in IN1 input, the OUT1 output switches on.

TASK IN1 HI RELAY2 OFF

After HI status appears in IN2 input, the OUT2 output switches off.

TASK IN2 LO RELAY1 TIME 30

After LO status appears in IN2 input, the OUT1 output status changes for 

30 sec.

TASK IN1 HI RELAY2 TIME 10

After HI status appears in IN1 input, the OUT2 output status changes for 10 

sec.

TASK IN1 LO NONE

After LO status appears in IN1 input, no GRM-10 reaction.

TASK IN2 HI NONE

After HI status appears in IN2 input, no GRM-10 reaction.

TASK IN1 LO NONE MESSAGE 

WODA W POMIESZCZENIU

After LO status appears in IN1 input, the „WODA W POMIESZCZENIU” mes-

sage is sent.

TASK IN1 HI NONE MESSAGE 

WODA WYPOMPOWANA

After  HI  status  appears  in  IN1  input,  only  the  „WODA  WYPOMPOWANA” 

message is sent.

TASK IN1 LO RELAY1 ON MESSAGE

STAN NISKI NA IN1

After LO status appears in IN1 input, the OUT1 output switches on and a text 

message „STAN NISKI NA IN1” is sent.

TASK IN2 LO RELAY2 TIME 60 MESSAGE 

ODLICZANIE CZASU

After LO status appears in IN2 input, the OUT2 output changes for time t=60 

sec. + a text message „ODLICZANIE CZASU” is sent.

EF COMMAND

OUTPUT CONTROL COMMANDS

he command allows to configure text messages used to control EXTA FREE system wireless receivers and selected LED lighting fittings 

and controllers of intelligent lighting Ledix series system. The control is possible only when the GRM-10 device is connected with the 

RXM-01 translator (www.extafree.pl) by means of RS-485 bus.

EF 

<address> <K1..Kn> <control text message content>

<address> This parameter defines the RXM-01 translator address on MODBUS bus that the specific control command refers to. This 

parameter is configured in the range of 1 to 247.

<K1...Kn>  The parameter defines the the number of push-buttons used to control EXTA FREE system receivers (possible numbers from 

1 to 127). In one EF command up to 15 numbers of push-buttons can be configured. The push-buttons refer to a single control 

text message, for example in order to adjust several EXTA FREE system receivers by means of one text message.

<control text message content>  The control command is adjusted by a user, the maximum number of signs is 32.
The user can define 127 independent control commands. The commands can not be repeated - if the command including a given content 

already exists, the GRM-10 device will display ERROR as a response to this configuration text message. A similar message is given by 

the PC application. The control commands generated by the EF command are grouped in a table. Commands generated as text mes-

sages are placed at the end of the table and from a PC at the beginning. It should be helpful for the user to add new commands by means 

of a telephone. The maximum number of EF commands that can be configured is 127.
The EF commands table can be completely deleted by sending a 

EF RESET

 command in the configuration mode.

The user can configure the EF command in such a way as to adjust simultaneously several (up to 15) EXTA FREE / LEDIX system receiv-

ers, which are located within RXM-01 range. It is very important in creation the so called scenes or, for example, in the control of central 

roller blind drives. The next push-buttons codes are sent in a ”one by one” sequence with an interval of 1 second.
The cooperation of GRM-10 device with RXM-01 device is fully described in the 

EXTA FREE CONTROL section by means of GSM

.

Examples of commands:

Command

Description

EF 1 K1 OSWIETLENIE ON

A text message with the content ‘OSWIETLENIE ON’ – results in sending a code by RXM-01 with the 

0x0,1 address to press a 0x0,1 push-button. The result is that the receiver with this code is switched on. 

EF 1 K2 OSWIETLENIE OFF

A text message with the content ‘OSWIETLENIE OFF’ – results in sending a code by RXM-01 with the 

0x0,1 address to press a 0x0,2 push-button. The result is that the receiver with this code is switched off. 

EF 2 K3 SCHODY ON

A text message with the content ‘SCHODY ON’ – results in sending a code by RXM-01 with the 0x0,2 

address to press a 0x0,3 push-button. The result is that the receiver with this code is switched on. 

EF 2 K4 SCHODY OFF

A text message with the content ‘SCHODY OFF’ – results in sending a code by RXM-01 with the 0x0,2 

address to press a 0x0,4 push-button. The result is that the receiver with this code is switched on. 

EF 1 K3 ROLETY GORA

A text message with the content ‘ROLETY GORA’ – results in sending a code by RXM-01 with the 0x0,1 

address to press a 0x0,3 push-button. It results in opening the roller blind connected to SRP-02 with 

this code.

EF 1 K4 ROLETY DOL

A text message with the content ‘ROLETY DÓŁ’ – results in sending a code by RXM-01 with the 0x0,1 

address to press a 0x0,4 push-button. It results in closing the roller blind connected to SRP-02 with 

this code.

EF 1 K1 K3 ALL ON

 

(example of a stage)

A text message with the content ‘ALL ON’ – results in switching on the light and opening the roller 

blinds - it is equivalent to sending codes by RXM-01 with the 0x0,1 address to receivers to press 0x0,1 

and 0x0,3 push-buttons.

Command

Description

Przykład

RELAY1 ON

Switch on OUT1 output

-

RELAY1 OFF

Switch off OUT1 output

-

RELAY2 ON

Switch on OUT2 output

-

RELAY2 OFF

Switch off OUT2 output

-

RELAY1 TIME

Change of OUT1 output status for time t1[s] adjusted during configuration

-

RELAY2 TIME

Change of OUT2 output status for time t2[s] adjusted during configuration

-

RELAY1 TIME <t> Change of OUT1 output status for time <t> given in the control command. <t> parameter is ad-

justed in the range of 1 .... 3600.

RELAY1 TIME 60

RELAY2 TIME <t> Change of OUT2 output status for time <t> given in the control command. <t> parameter is ad-

justed in the range of 1 .... 3600.

RELAY2 TIME 10

GATE

Output control in the gate mode. Switching on the OUT1 output for the default time <TIME1> 

and the OUT2 output for the default time <TIME2>. If the AUTO parameter is adjusted for the 

gate mode, the pulse to close the gate is automatically generated after time <TIME3> is finished. 

Times <TIME1>, <TIME2> and <TIME3> are adjusted during the gate mode configuration.

-

GATE <t1> <t2>

Output control in the gate mode. Switching on the OUT1 output for time <t1> and the OUT2 out-

put for time <t2>. The <t1> parameter is adjusted in the range of 0 .... 10 and the <t2> parameter 

in the range of 0 .... 360. If the AUTO parameter is adjusted for the gate mode, the pulse to close 

the gate is automatically generated after time <TIME3> is finished. Time <TIME3> is adjusted 

during the gate mode configuration.

GATE 2 120

STATUS

Checking the output/input status (section: GRM-10 DEVICE REPLY TO STATUS COMMAND)

-

CAUTION: If the PASS parameter (password to a text message) was adjusted during configuration in the CONFIG command, 

then the adjusted password must be typed during the text message control at the beginning.

Example: (adjusted password „Zamel”): 

Zamel RELAY1 ON; Zamel RELAY2 OFF; Zamel RELAY1 TIME 10; Zamel GATE; Zamel GATE 2 20

WARRANTY CARD

There is 24 months guarantee on the product

Salesman stamp and signature, date of sale

1. ZAMEL Sp. z o.o. assures 24 months guarantee for the product.

2. The manufacturer’s guarantee does not cover any of the following actions:

a) mechanical damage during transport, loading / unloading or under other circumstances,

b) damage caused by incorrect product mounting or misuse,

c) damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product or any other devices 

needed for the product functioning,

d) damage caused by Act of God or any other incidents independent of the manufacturer - ZAMEL Sp z o.o.

e) power source (batteries) in the device during sale (if any).

3. The PURCHASER shall lay any claims in writing to the dealer or ZAMEL Sp. z o.o.

4. ZAMEL Sp. z o.o. is liable for processing any claim according to current Polish legislation.

5. ZAMEL Sp. z o.o. shall process the claim at its own discretion: product repair, replacement or money return.

6. The manufacturer’s guarantee is valid in the Republic of Poland.

7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or 

otherwise are not affected by this warranty.

Содержание GRM-10

Страница 1: ...puts with a maximum load capacity of 16 A 250 V AC Two digital inputs allow for a link with the alarm control panels The RS485 in terface in connection with the RXM 01 translator gives a possibility t...

Страница 2: ...he GRM 10 application on the PC 1 After switching off the power supply voltage connect the GRM 10 device to the PC by means of a USB Micro B USB cable and pressing the PK2 push button 2 Start the GRM...

Страница 3: ...pes Remarks MANUAL By means of PK1 PK2 push buttons on the front panel Bistable ON OFF Time TIME Gate GATE Times for TIME and GATE modes are adjusted during con figuration CLIP By calling to the devic...

Страница 4: ...essively entered phone numbers preceded by 48 The text messages will be sent to these numbers The confirma tions refer to the changed output status and occurences on IN1 IN2 inputs The maximum of numb...

Страница 5: ...ng a text message MESSAGE with a defined content X number of an input output 1 input output IN1 OUT1 2 input output IN2 OUT2 tx f the output must be active for a period of time TIME then the parameter...

Страница 6: ...s is 0x01 The address is important for a larger number of RXM 01 operating independently on a single object 3 Following the description of the PC add programme particular push but tons sent by the RXM...

Страница 7: ...X ON Electronics Authorized Distributor Click to view similar products for LED Lighting Fixture Accessories category RZB03 ASM10 ORDBYE115 STR21230V AS223 ORAE1336G ORAE1373 ORWE501 ORWE504 ORWE514...

Отзывы: