background image

CONFIGURATION COMMANDS

CONFIG COMMAND

Command

Description

CONFIG

●  Configuration of telephone numbers authorized to control the CLIP.

●  Configuration of the optional password for controlling text messages.

●  Configuration of confirmation.

CONFIG MODE

●  Adjusting the device for the remote configuration mode.

CONFIG MODE END

●  Deleting the remote configuration mode. 

ADD NUM

●  Entering additional phone numbers to the list of numbers authorised to control the CLIP. By means of 

one commend maximum six numbers can be added every time. Applies to local and remote configura-

tion

DEL NUM

●  Deleting a number (s) from the list of telephone numbers authorized to control the CLIP. Every time by 

means of one command up to six numbers may be deleted. It refers to local and remote configuration.

ADMIN

●  Configuration of telephone numbers authorized to a remote configuration.

INFO

●  Configuration of telephone numbers the text messages will be sent to (it refers to the outputs’ status 

and occurrences on IN1, IN2 inputs). 

RELAY1

●  Operation mode configuration for CH1 output.

●  Operation mode configuration of CH1 output after power supply voltage is switched off.

RELAY2

●  Operation mode configuration for CH2 output.

●  Operation mode configuration of CH2 output after power supply voltage is switched off.

MODBUSCONFIG

●  Configuration of RS485 transmission parameters for MODBUS protocol.

GATE

●  Gate mode configuration.

TASK IN1

●  IN1 input configuration.

TASK IN2

●  IN2 input configuration.

EF

●  Control command configuration for EXTA FREE system.

EF RESET

●  Deleting the control command table for EXTA FREE system. 

RESET CONFIG

●  Restore the default settings (it does not refer to EXTA FREE commands).

CONFIG

 <+48tel_1> <+48tel_n> 

PASS

 <password from 5 to 8 signs> 

ACK

 <REL1,REL2, REL12>

The maximum of numbers available n = 6

PASS

  Keyword - it specifies the password added to the text message during control. The password is added at the beginning of the 

message. No parameter means a free access for any number during text message control.

ACK

  Keyword - it specifies whether the GRM-10 device must send a confirming text message every time after a specified command 

is realised:

REL1

  confirmation only for CH1 channel

REL2

  confirmation only for CH2 channel

REL12

  confirmation for channels CH1 and CH2

<> 

No parameter means no confirmation for channels CH1 and CH2

Examples of commands:

Command

Description

4860248600915257

N48602360938, +48600915257 globally  released to 

control CLIP, no password for text message control, no confirma-

tions for OUT1 and OUT2 outputs.

4860248600915257 ACK REL1

N48602360938, +48600915257 globally released to 

control CLIP, no password for text message control, confirmations 

only for OUT1 output.

4860248600915257 ACK REL2

N48602360938, +48600915257 globally released to 

control CLIP, no password for text message control, confirmations 

only for OUT2 output.

4860248600915257 ACK REL12

N48602360938, +48600915257 globally released to 

control CLIP, no password for text message control, confirmations 

for OUT1 and OUT2 outputs.

4860248600915257 PASS ZAMEL ACK REL1

N48602360938, +48600915257 globally released to 

control CLIP, ZAMEL password for text message control, confir-

mations only for OUT1 output.

NOTE: If there is a need to add more authorised numbers to control the CLIP (including control in the gate mode) it can be 

done by means of the PC application (telephone section) or the ADD NUM command in configuration mode. It is possible to 

enter up to 500 numbers. In order to delete the selected telephone number, use the PC application or the DEL NUM command 

in configuration mode.

DEVICE CONTROL

Type of control

Possible control types

Remarks

MANUAL

By means of PK1 / PK2 push buttons on 

the front panel

●  Bistable ON/OFF

●  Time TIME

●  Gate GATE

●  Times for TIME and GATE modes are adjusted during con-

figuration.

CLIP

By calling to the device

(specified number of signals)

●  Bistable ON/OFF

●  Time TIME

●  Gate GATE

●  Times for TIME and GATE modes are adjusted during con-

figuration.

●  The  number  of  signals  specified  during  configuration  (in 

ON / OFF and TIME modes the user must disconnect after 

certain number of signals, in the GATE mode the discon-

nection is automatical.

TEXT MESSAGE

By sending a specified message with a 

control command to the device

●  Bistable ON/OFF

●  Time TIME

●  Gate GATE

●  EXTA FREE control

●  Times for the TIME and GATE modes are adjusted during 

configuration with a possibility of changing the text in the 

control text message.

ON / OFF bistable mode

 - change of the CH1 or CH2 output status to the opposite.

TIME time mode

 - change of the CH1 or CH2 output status to the opposite and appropriately  through time t1 for CH1 output and time 

t2 for CH2 output.

GATE gate mode

 - change of the CH1 and / or CH2 into times defined for the gate mode.

EXTA FREE control

 - control of EXTA FREE system wireless receivers by means of RXM-01  device RXM-01 connected with the GRM-

10 device.

ADD NUM COMMAND

DEL NUM COMMAND

CONFIGURATION MODE COMMAND

CONFIGURATION MODE END COMMAND

The command adds a telephone number / numbers to the authorised list of numbers used to control CLIP (including the control in the 

gate mode). 6 telephone numbers maximally can be added by one command at each time. The command refers to the local and remote 

configuration.

ADD NUM 

<+48tel_1> <+48tel_2>,...,<+48tel_n>

tel_1...tel_n  successively entered phone numbers preceded by +48.

The maximum of numbers available n = 6.
Examples of commands:

Command

Description

ADD NUM +48602360938

48602360938 is added to the authorised list of numbers 

used to control by means of CLIP calling signals.

ADD NUM+486034860048600500800

N486034860048600500800 are add-

ed to the authorised list of numbers used to control by means of 

CLIP calling signals.

The command deletes a telephone number / numbers from the authorised list of numbers used to control CLIP (including the control in 

the gate mode). 6 telephone numbers maximally can be deleted by one command at each time. The command refers to the local and 

remote configuration.

DEL NUM 

<+48tel_1> <+48tel_2>,...,<+48tel_n>

tel_1...tel_n  successively entered phone numbers preceded by +48.

The maximum of numbers available n = 6.
Examples of commands:

Command

Description

DEL NUM +48602360938

48602360938 is deleted from the authorised list of num-

bers used to control by means of CLIP calling signals.

DEL NUM+486034860048600500800

N486034860048600500800 are de-

leted from the authorised list of numbers used to control by means 

of CLIP calling signals.

The command makes the GRM-10 device enters from the normal operation mode into the remote configuration mode. The active com-

mand is only for the numbers included in the ADMIN list (by means of ADMIN command or the PC application). The enter into the con-

figuration mode is indicated by a flashing LED diodes LEDP1 and LEDP2.

The command allows the the GRM-10 device to go out from the configuration mode to normal operation. The active command is only 

for the numbers included in the ADMIN list (by means of ADMIN command or the PC application). The command is inactive during 

local configuration.

Содержание GRM-10

Страница 1: ...puts with a maximum load capacity of 16 A 250 V AC Two digital inputs allow for a link with the alarm control panels The RS485 in terface in connection with the RXM 01 translator gives a possibility t...

Страница 2: ...he GRM 10 application on the PC 1 After switching off the power supply voltage connect the GRM 10 device to the PC by means of a USB Micro B USB cable and pressing the PK2 push button 2 Start the GRM...

Страница 3: ...pes Remarks MANUAL By means of PK1 PK2 push buttons on the front panel Bistable ON OFF Time TIME Gate GATE Times for TIME and GATE modes are adjusted during con figuration CLIP By calling to the devic...

Страница 4: ...essively entered phone numbers preceded by 48 The text messages will be sent to these numbers The confirma tions refer to the changed output status and occurences on IN1 IN2 inputs The maximum of numb...

Страница 5: ...ng a text message MESSAGE with a defined content X number of an input output 1 input output IN1 OUT1 2 input output IN2 OUT2 tx f the output must be active for a period of time TIME then the parameter...

Страница 6: ...s is 0x01 The address is important for a larger number of RXM 01 operating independently on a single object 3 Following the description of the PC add programme particular push but tons sent by the RXM...

Страница 7: ...X ON Electronics Authorized Distributor Click to view similar products for LED Lighting Fixture Accessories category RZB03 ASM10 ORDBYE115 STR21230V AS223 ORAE1336G ORAE1373 ORWE501 ORWE504 ORWE514...

Отзывы: