background image

Use and programming

Coffee Pouring

On  pressing  the  corresponding  button 
T1-T2-T3  or  T4,  the  corresponding 
delivery solenoid valves are activated for 
the time necessary to obtain the required 
amount  of  product  as  previously 
programmed (volumetric check).
The  delivery  in  progress  may  be 
suspended  before  actually  reaching  the 
desired programmed product quantity by 
pressing button T5 Stop.
It is also possible to obtain simultaneous 
coffee  delivery  from  all  the  machine 
groups.

Continuously Coffee Pouring

For  continuous  coffee  measure  delivery 
press  button  T5  from  the  keyboard 
corresponding to the group head   which 
one  wishes  to  operate.  Press  again  the 
same button T5 to Stop.

Pre infusion

O u r   s o f t w a r e   p e r m i t s   m e a s u r e  
configuration so that the relative delivery 
of  the  COFFEE  measures  through 
volumetric control is
preceded by pre-infusion. Delivery of the 
coffee  measure  after  time  1  (ON)  is 
suspended for a time 2 (OFF) and is then 
resumed for the completion of selection. 
On pressing one of the volumetric control 
measure  buttons,  the  normal  delivery 
cycle is preceded by a short timed water 
jet in order to dampen the coffee before 
actual delivery stage.
This  function  ensures  the  optimum 
extraction  especially  for  espresso 
coffees.

0

1

2

T1 T2 T3 T4 T5

T1 single espresso coffee

T2 double espresso coffee

T3 single long coffee

T4 double long coffee

T5 programming/continuos
     and stop

T1

T2

T3

T4

T5

Boiler (filling) level time out

This  alarm  condition  occurs  whenever 
the  water  level  is  too  low  or  the  level 
probe remains uncovered. In such a case 
all the buttons are lit.
The filling stage is automatically engaged 
and to cancel the alarm conditions switch 
the machine off and then on again.

Alarm conditions all  buttons lit 

T5

T4

T3

T2

T1

8

ZagatO

Espresso Italia PTY LTD 

www.espressoitalia.com.au 

Freecall 1300 660 976

Содержание ESPRESSO COFFEE MACHINE

Страница 1: ...e we recommend to read the following instructions thoroughly which explains how to install and use the unit Instruction Manual ZagatO Macchina da Caffe Espresso coffee machine Maquina para caf expr s...

Страница 2: ...the machine in the most efficient way and how to react if malfunction will occur Store this manual carefully If you should lose it you can ask for and additional copy from the distributor Index Read t...

Страница 3: ...r question concerning specific situations or problem please contact the local dealer or manufacturer directly Power Cord Never use this unit with a defective power cord Replace defective power cords a...

Страница 4: ...5 2 5 1 0 1 5 2 5 1 2 3 7 4 4 5 6 9 10 11 8 8 12 12 0 1 2 Positioning Place the unit on a level surface Keep 5 cm of clear space from the side wall of the unit and 10 cm from the rear In order to fun...

Страница 5: ...0W 5500W Brewing Group Heads 1 2 3 Steam Wand s 1 2 2 Hot Water 1 1 1 Electronic Multiple pre brewing volume setting Auto self cleaning Temperature control 1 2 bar pressure switch for heated water out...

Страница 6: ...r engaged filled with ground dosed and pressed coffee in order to achieve an effective working pressure of 8 9 atm Should re calibration of the pump pressure be necessary this operation should be unde...

Страница 7: ...shown in the figure and on the pressure switch itself The pressure varies by 0 1 atm for every complete screw turn Pump pressure adjustment Insert the filter holder into the unit filled with regularly...

Страница 8: ...ol is preceded by pre infusion Delivery of the coffee measure after time 1 ON is suspended for a time 2 OFF and is then resumed for the completion of selection On pressing one of the volumetric contro...

Страница 9: ...ing mode no pre infusion 0 1 2 T1 T2 T3 T4T5 ON IMPORTANT The programming of every dose must be done with ground coffee and not with previously used grounds With machines having two or three groups by...

Страница 10: ...d Press buttonT5 to confirm Press buttonT5 to confirm 7 6 9 8 8 Flash Flash Flash Light Light Light Light Light T1 T2 T3 T4 T5 T5 T4 T3 T2 T1 0 1 2 T1 T2 T3 T4T5 9 Programming with pre infusion Button...

Страница 11: ...nozzles must be cleaned immediately after use in order to prevent the risk of the formation of any scale which may block the holes and to ensure that any drinks made subsequently do not absorb any un...

Страница 12: ...will compromise the quality of the coffee and will also cause problems such as bad extraction and coffee grounds at the bottom of the cup Showers The showers D should be cleaned weekly in hot water T...

Страница 13: ...T3 button Rinse out the unit using a normal filter and then undertake a few dispensing operations using water only Then prepare a coffee in order to eliminate any detergent residue Machine maintenance...

Страница 14: ...er 2 Adjust the grinder doser 1 Dirty clogged drain box 2 Drainage pipe clogged or detached 3 Other internal leakages 1 Clean the drain box 2 Replace clean the drainage pipe 3 Contact specialized pers...

Страница 15: ...ctrical connection 4 Partially burnt out element CAUSE SOLUTION 1 Contact specialized personnel 2 3 4 1 Contact specialized personnel 1 Contact specialized personnel 1 Contact specialized personnel 1...

Страница 16: ...details to the product We guarantee that these instructions reflect the actual state of the product at the moment of its sale in the market We also would like to use this occasion to invite you to of...

Отзывы: