background image

Calibration

Pressure switch adjustment

The pressure switch shown in the figure 
acts to keep the
boiler pressure constant by engaging or 
de-activating the electrical
heating resistance.
This pressure switch is already calibrated 
to 1.1-1.3 bar during the
initial machine testing stage, but should a 
different working pressure
be  required,  it  is  possible  to  vary  the 
operational field of the pressure
switch  using  the  regulation  screw  (U); 
pressure reduction results in
a  reduction  in  temperature,  whilst 
increasing the pressure will also
increase the water temperature.
The  regulation  direction  is  shown  in  the 
figure and on the pressure
switch itself.
The pressure varies by 0.1 atm for every 
complete screw turn,

Pump pressure adjustment

Insert  the  filter  holder  into  the  unit  filled 
with regularly ground, dosed
and  pressed  coffee.  Press  one  of  the 
coffee button   and read the pressure on 
the pump pressure gauge
NB: The correct pressure is of 8-9 atm.
Should  the  pressure  indicated  on  the 
pressure gauge be incorrect,
turn  it  clockwise  to  increase  the  pump 
pressure and anti-clockwise
to reduce the pressure.
Once  adjustment  is  complete  check 
pump calibration by delivering
one or more coffees.
Z= Pump pressure adjustment screw.

!

WARNING

Disconnect  the  electricity  supply  before 
undertaking this operation.

!

7

ZagatO

TEC

TEC

Espresso Italia PTY LTD 

www.espressoitalia.com.au 

Freecall 1300 660 976

Содержание ESPRESSO COFFEE MACHINE

Страница 1: ...e we recommend to read the following instructions thoroughly which explains how to install and use the unit Instruction Manual ZagatO Macchina da Caffe Espresso coffee machine Maquina para caf expr s...

Страница 2: ...the machine in the most efficient way and how to react if malfunction will occur Store this manual carefully If you should lose it you can ask for and additional copy from the distributor Index Read t...

Страница 3: ...r question concerning specific situations or problem please contact the local dealer or manufacturer directly Power Cord Never use this unit with a defective power cord Replace defective power cords a...

Страница 4: ...5 2 5 1 0 1 5 2 5 1 2 3 7 4 4 5 6 9 10 11 8 8 12 12 0 1 2 Positioning Place the unit on a level surface Keep 5 cm of clear space from the side wall of the unit and 10 cm from the rear In order to fun...

Страница 5: ...0W 5500W Brewing Group Heads 1 2 3 Steam Wand s 1 2 2 Hot Water 1 1 1 Electronic Multiple pre brewing volume setting Auto self cleaning Temperature control 1 2 bar pressure switch for heated water out...

Страница 6: ...r engaged filled with ground dosed and pressed coffee in order to achieve an effective working pressure of 8 9 atm Should re calibration of the pump pressure be necessary this operation should be unde...

Страница 7: ...shown in the figure and on the pressure switch itself The pressure varies by 0 1 atm for every complete screw turn Pump pressure adjustment Insert the filter holder into the unit filled with regularly...

Страница 8: ...ol is preceded by pre infusion Delivery of the coffee measure after time 1 ON is suspended for a time 2 OFF and is then resumed for the completion of selection On pressing one of the volumetric contro...

Страница 9: ...ing mode no pre infusion 0 1 2 T1 T2 T3 T4T5 ON IMPORTANT The programming of every dose must be done with ground coffee and not with previously used grounds With machines having two or three groups by...

Страница 10: ...d Press buttonT5 to confirm Press buttonT5 to confirm 7 6 9 8 8 Flash Flash Flash Light Light Light Light Light T1 T2 T3 T4 T5 T5 T4 T3 T2 T1 0 1 2 T1 T2 T3 T4T5 9 Programming with pre infusion Button...

Страница 11: ...nozzles must be cleaned immediately after use in order to prevent the risk of the formation of any scale which may block the holes and to ensure that any drinks made subsequently do not absorb any un...

Страница 12: ...will compromise the quality of the coffee and will also cause problems such as bad extraction and coffee grounds at the bottom of the cup Showers The showers D should be cleaned weekly in hot water T...

Страница 13: ...T3 button Rinse out the unit using a normal filter and then undertake a few dispensing operations using water only Then prepare a coffee in order to eliminate any detergent residue Machine maintenance...

Страница 14: ...er 2 Adjust the grinder doser 1 Dirty clogged drain box 2 Drainage pipe clogged or detached 3 Other internal leakages 1 Clean the drain box 2 Replace clean the drainage pipe 3 Contact specialized pers...

Страница 15: ...ctrical connection 4 Partially burnt out element CAUSE SOLUTION 1 Contact specialized personnel 2 3 4 1 Contact specialized personnel 1 Contact specialized personnel 1 Contact specialized personnel 1...

Страница 16: ...details to the product We guarantee that these instructions reflect the actual state of the product at the moment of its sale in the market We also would like to use this occasion to invite you to of...

Отзывы: