Z3-MVE-100 V1.05.01a
___________________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 U.S.A.
♦
+1.402.323.0702
17
6.0
RUNNING DECODE ON THE Z3-MVE-100
Decode and verifying the output requires a source streaming over the Ethernet (another Z3-MVE-
100 unit, for example), an Ethernet cable, a hub/router, an HDMI cable, and a monitor with HDMI
input.
(1) Follow the steps described in Section
Error! Reference source not found.
to connect the Z3-
MVE-01 and access the web server to control settings (Steps (1) to (7)).
(2) Connect the streaming source to a hub/router that is connected to the control PC. Connect the
Ethernet port of the Z3-MVE-100 to this same hub/router:
(3) Connect “HDMI Out” of the Z3-MVE-100 with an HDMI cable to an HDMI monitor.
(4) The control PC should still have the Web GUI of the Z3-MVE-100. If the encoder is still running
from the previous demo, click “Stop” just to the left of “Start” (
Figure 10
).
(5) In the bottom right corner is an “Operating Mode” selector. Change this to “Decoder”:
Figure 14 MVE-100 Connections for Decode
(1) Connect to hub/router
connected to PC and
streamer
(2) Connect
to HDMI
monitor
Figure 15 Operating Mode Selector
Change to “Decoder”