6
SENSOR_MULTILEVEL_REPORT
[Command Class Sensor Multilevel, Sensor Multilevel
Report, Sensor Type = 0 x 01 (Air Temperature),
PrScale+Size = 0 x 2A, Sensor Value 1 = (High
Byte of Temperature Value), Sensor Value 2 = (Low Byte
of Temperature Value)]
1-1-3 Low Battery Report
When the battery level of the detector drops to an unacceptable level,
the icon
will appear on the LCD and the detector will emit
ALARM_REPORT command to the nodes of Grouping 1.
ALARM_REPORT Command
[Command Class Alarm, Alarm Type = 0x01, Alarm Level =
255(0xFF)]
The users can also enquire the battery status of the detector by sending
BATTERY_ GET command via controller. Once the detector receives
the command, it will return BATTERY_REPORT command.
BATTERY_REPORT
[Command Class Battery, Battery Report, Battery Level =
20%-100%]
If it displays with a message of “Battery Level = 255 (0xFF)”, it implies
that the detector is at low battery status. Please replace the batteries
as soon as possible, otherwise the detector will enter Shut Down mode.
Note:
The detector will emit a low battery command as long as there is a
device associated into Grouping 1 of Temp./Humid. Detector, even if the
RF function is set to disable.
1-2 Grouping 2 (Max. Node = 3)
1-2-1 Control Other Devices (Basic Set)
When the detector is triggered, it will emit BASIC_SET_COMMAND to
the nodes of Grouping 2.
[Command Class Basic, Basic Set, Value = (255)0xFF]
: send
trigger-ON command
[Command Class Basic, Basic Set, Value = 0(0x00)]
: send
trigger-OFF command
Please refer to the table below, configuration parameter 1, for the setting
of basic set command.
2. Z-Wave’s Configuration
The table below lists the configuration parameters and the value range for
users to set up the detector.
Parameter
Function
Size
(Byte)
Value
Unit
Default Set/
Factory Default
Description
1
Basic Set Level
1
0~99
% of
Brightness
(Dimmer
Level)
99 / 99
Set basic set value to
be on (or Dim Level) /off
0: Disable
2 Temperature
Trigger-ON Value
1 -20~50
or
99
Degree
30 / 99
Set temp.trigger-ON
value to be _ degree.
99: Clear Temp.
trigger-ON value
3 Temperature
Trigger-OFF
Value
1 -20~50
or
99
Degree
20 / 99
Set temp.trigger-OFF
value to be _ degree.
99: Clear Temp.
trigger-OFF value
4 Humidity
Trigger-ON
Value
1 20~90
or
99
%
50 / 99
Set humid. trigger-ON
value to be _%.
99: Clear Humid.
trigger-ON value
5 Humidity
Triger-OFF Value
1 20~99
or
99
%
40 / 99
Set humid. trigger-OFF
value to be _%.
99: Clear Humid.
trigger-OFF value
6 Auto
Report
(Time Interval)
2 1~1439
or
99
Minutes
0/0
Set auto report time
interval to be _ mins
0: Disable auto report
7 Auto
Report
(Temp. Change)
1 1~70
or
0
Degree 0/0
Set auto report temp.
trigger interval to be
_ degree.
0: Disable auto report
8 Auto
Report
(Humid. Change)
1 5~70
or
0
% 0/0
Set auto report humid.
trigger interval to be
_ %.
0: Disable auto report
Note:
Default set is the preset value of the detector. For instance, if default set of
Temp. trigger-ON is selected, the detector will be triggered ON if temperature
reaches 30
。
C . You can skip the hassle of selecting a value from -20 to 50
degrees if default set is selected.
Factory default value is the original value of the detector without any setting.
Once the function of reset is executed, the detector will be restored to its
factory default status, so as the settings.