5
Note:
The humidity of trigger-ON and trigger-OFF cannot be set equal; there MUST
be at least
5%
difference in between. For example, if now the trigger-ON
humidity is already set to be 50%, so trigger-OFF humidity can only be
45%
≦
or
≧
55%. (Values between 45% and 55% cannot be set.)
Once the detector has been triggered, the humidity must raise up or drop down
at least
5%
from the preset value before it can be triggered again. For example,
if the detector has been triggered on at 50%, then the temperature must be
≧
55% or
≦
45% before it can be re-triggered.
3. Radio Frequency
This function is designed to enable or disable the sending of RF command which
comprised of Z-wave protocol to the associated nodes, as Temp./Humid.
Detector has been triggered on/off.
Press
and select MODE 7, the icon
should flash. Press
to
turn On (enable) the function or
to turn OFF (disable) the function.
Note:
If the RF mode is OFF, no command will be sent even the Temp./Humid.
Detector has been triggered. If RF is ON and the detector has been
triggered, the RF command will be sent to nodes of Grouping 2.
If the RF reading is 00, it implies no node ID has been allocated by Z-Wave
Controller. Please execute inclusion mode as described on page 1.
4. Beep Tone
To set the beep tone, press
and select MODE 8. The icon
flashes.
Press
for ON and
for OFF. If it is ON, a beep tone will be sounded
whenever a button is pressed; 4 continuous beep tones will be sounded for 1
second if the detector has been triggered.
Programming
1. Z-Wave’s Groups (Association Command Class Version 2)
The Temp./Humid. Detector can be set to send reports to or control associated
Z-Wave devices. It supports two association groups with one node support for
Grouping 1 and three nodes support for Grouping 2.
Grouping 1 includes POWER_APPLIED, SENSOR_MULTILEVEL _REPORT,
ALARM_REPORT an d BATTERY_REPORT_COMMAND
Grouping 2 includes BASIC_SET
1-1 Grouping 1 (Max. Node = 1)
1-1-1 POWER_APPLIED command
Whenever power is applied, it will send ALARM_REPORT command to
the nodes of Grouping 1 to inform the devices that the detector is
powered up.
ALARM_REPORT Command
[Command Class Alarm, Alarm Type = 0x02, Alarm Level =
0x01]
1-1-2 MULTILEVEL_SENSOR_REPORT
The detector will emit SENSOR_MULTILEVEL_REPORT to inform the
nodes of Grouping 1 automatically its current temperature and humidity.
Refer to the section of Z-Wave’s Configuration as described on page 6
for settings of auto report configuration.
1-1-2-1
Humidity
SENSOR_MULTILEVEL_REPORT
[Command Class Sensor Multilevel, Sensor Multilevel
Report, Sensor Type = 0 x 05 (Relative Humidity),
PrScale+Size = 0 x 01, Sensor Value 1 = 20-90%]
Example:
Sensor Value 1 = 0x23
Humidity Value = Sensor Value = 35 (%)
1-1-2-2
Temperature
(Celsius)
SENSOR_MULTILEVEL_REPORT
[Command Class Sensor Multilevel, Sensor Multilevel
Report, Sensor Type = 0 x 01 (Air Temperature),
PrScale+Size = 0 x 22, Sensor Value 1 = (High
Byte of Temperature Value), Sensor Value 2 = (Low Byte
of Temperature Value)]
Example:
Sensor Value 1 = 0x01
Sensor Value 2 = 0x31
Temperature (C) = (Sensor Value 1*256 + Sensor Value 2)/10
=
(1*256+49)/10
=
30.5
(C)
1-1-2-3
Temperature
(Fahrenheit)