Function Description
LED
Indication
1. Have Z-Wave Controller entered
exclusion mode.
2. Pressing key 3 times within
1.5 seconds will enter exclusion mode
flashes
Exclusion
Node ID has been excluded
The RF reading displays 00
(MODE 7)
1. Pressing key 3 times within
1.5 seconds will enter inclusion mode
2. Within 1 second, press key
again and hold it until long beep tone
is off
flashes
Reset
3. Node ID has been excluded; restore
to factory default.
The RF reading displays 00
(MODE 7)
1. Have Z-Wave Controller entered
association mode.
2. Pressing key 3 times within
1.5 seconds will enter association
mode
flashes
Association
3. There are two groupings – 1 and 2.
Refer to Z-Wave’s Groupings as
described on page 5.
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node ID allocated
by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller.
Choosing a Suitable Location
The Temp./Humid. Detector can either be mounted on a wall or can be
freestanding on a table. Please consider a most suitable way before mounting/
placing it.
Wall Mounting
1. Place mounting bracket over a desired location on the wall. Through the 2
screw holes of the bracket, mark the mounting surface with a pencil.
2. Where marked, drill holes into mounting surface using an appropriate size
drill bit and insert the plastic wall plugs supplied respectively.
3. Screw mounting bracket onto the mounting surface. Ensure that the
screws are flush with the bracket.
4. Snap the Temp./Humid. Detector into place on the mounting bracket.
5. Secure with the fixing screw supplied.
FIGURE 1
FIGURE 2
Table Placing
1. Insert the stand into the hole on mounting bracket and turn 90 degrees
clockwise.
2. Once snapped in place, the detector can be placed on a shelf, table or other
surface where the temperature and humidity measurements are desired.
FIGURE3
FIGURE 4
Note:
Take care when fixing the detector to a metal surface, or mounting within
1m of metalwork (i.e. radiators, water pipes, etc) as this could affect the radio
range of the device.
Installation
Please follow the steps below in sequence to load the batteries.
1.
Undo and remove the screw from the bottom edge
of the detector to detach the rear cover.
2. Open the mounting bracket.
3. Unscrew the screw from the battery cover.
4. Remove the battery cover.
5. Insert 3 AA-size 1.5V alkaline batteries to the
battery compartment, ensuring correct polarity is
put.
6. Replace the battery cover and then engage the
detector to the rear cover firmly.
1
2
Plastic Wall Plug
3
4