Product description

The Z-Wave.Me Remote controls Z-Wave actuators such as dimmers, switches, thermostats or motor controls
for blinds or jalousies and it can activate scenes in central gateways or any other Z-Wave devices. Devices can
be turned on and off but dimmers and motor controls can also be turned into a desired dimming level to motor
position by keeping a button pushed and releasing it. Although it is controlling other devices, the device can
not act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller
to be included into a Z-Wave network. The device can be used in different modes that are selected by
configuration parameters 11-21:

1.  Direct control of associated devices
2.  Control of all devices in the Z-Wave network
3.  Simple and enhanced scene activation

10 pair of buttons - illuminated by blue light when operated - allow to control up to 10 control groups (either
association groups or scenes)

Batteries

The unit is operated by batteries. Use only batteries of correct type. Never mix old and new batteries in the
same device. Used batteries contain hazardous substances and should not be disposed of with household
waste!

Battery Type:  4 * AAA

Behavior within the Z-Wave network

I

 On factory default the device does not belong to any Z-Wave network. The device needs to join an

existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also leave a network. This process is called Exclusion. Both processes are initiated by the primary
controller of the Z-Wave network. This controller will be turned into exclusion respective inclusion mode.
Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion
mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave the
network. Leaving the network - i.e. being excluded - sets the device back to factory default.

If the device already belongs to a network, follow the exclusion process before including it in your network.
Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to
be reset first.

For including/excluding the remote control into an existing the Z-Wave network do the following steps:

Bring your primary controller into inclusion mode.

For Inclusion press the "Inclusion" button 3 times. The LED will flash green for a moment for
confirmation.

For Exclusion press the "Exclusion" button for 5 secs. The LED will flash green for a moment for
confirmation.

Operating the device

Содержание ZME RC2

Страница 1: ...ntrollers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated remote controls R This results in a number of possible communication patterns within a Z Wave network that are partly or completely supported by a specific...

Страница 2: ...nd should not be disposed of with household waste Battery Type 4 AAA Behavior within the Z Wave network I On factory default the device does not belong to any Z Wave network The device needs to join an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initia...

Страница 3: ...es are controlled using Basic Set On Off commands and SwitchMultilevel Dim Start Stop This mode implements communication pattern 7 Each button of the button group has different functions On short click turn on device s On pushed dim up light or wind up jalousie until button is released Off short click turn off device s Off pushed dim down light or wind down jalousie until button is released Status...

Страница 4: ... sleep state most of the time to save battery life time Communication with the device is limited In order to communicate with the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state Without such a controller communication may become impossible and or the ba...

Страница 5: ... another device is called association In order to control a different device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common...

Страница 6: ...er Number 10 Parameter Size 1 This parameter defines the command to be sent to devices of control group 1 when the related button is pressed association group 2 Value Description 0 Disabled 1 Switch On Off and Dim send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes Command to Control Group 2 association group 3 Par...

Страница 7: ... and Dim send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes Command to Control Group 5 association group 6 Parameter Number 14 Parameter Size 1 This parameter defines the command to be sent to devices of control group 5 when the related button is pressed association group 6 Value Description 0 Disabled 1 Switch On...

Страница 8: ...m send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes Command to Control Scene 1 association group 9 Parameter Number 17 Parameter Size 1 This parameter defines the command to be sent to devices of control scene group 1 when the related button is pressed association group 9 Value Description 0 Disabled 1 Switch On ...

Страница 9: ...ssociation group 11 Value Description 0 Disabled 1 Switch On Off and Dim send Basic Set and Switch Multilevel 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes Default 5 Send Preconfigured Scenes Command to Control group All On Off association group 12 Parameter Number 20 Parameter Size 1 This parameter defines the command to be sent to devices of control group All On Off when the rel...

Страница 10: ...tion version 1 Manufacturer Specific version 1 Protection version 1 Battery version 1 Wake Up version 2 Association version 2 Version version 1 Multi Channel Association version 2 Multi Channel version 3 Basic version 1 Multilevel Switch version 1 All Switch version 1 Scene Activation version 1 Controlled Command Classes Multi Channel version 3 Basic version 1 Multilevel Switch version 1 All Switc...

Страница 11: ...y one primary controller in a Z Wave network Inclusion is the process of bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node ...

Страница 12: ... PDQXDOV ZDYHHXURSH FRP PDNH SKS ODQJ HQ W SH VNX 0 B5 KWWS PDQXDOV ZDYHHXURSH FRP PDNH SKS ODQJ HQ W SH VNX 0 B5 ...

Отзывы: