out a Node Information Frame.

Pressing the "INCL." button for three times will send out a Node Information Frame.

LED Control

Green blinking 1Hz frequency: Learning Mode

Red blink: No program/ invalid button press / The protection is set

Yellow for 3 sec: The On button command was send successfully

Blue for 3 sec: The Off button command was send successfully

Yellow/RED for 3 sec: The On button command was send unsuccessfully

Blue/RED for 3 sec: The Off button command was send unsuccessfully

Red blinking 2Hz frequency: The batterry seems to be low.

Yellow/Blue/Red 3sec: The protection is unlocked

Blinking Blue - we are dimming.

Associations

A

 Z-Wave devices control other Z-Wave devices. The relationship between one device controlling

another device is called 

association. In order to control a different device, the controlling device needs to

maintain a list of devices that will receive controlling commands. These lists are called association groups and
they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all
devices stored in the respective association group will receive a common wireless command.

Association Groups:

1

Lifeline. Send to controller battery level and WakeUp Notification (max. nodes in group: 5)

2

The buttons of group №1 (max. nodes in group: 5)

3

The buttons of group №2 (max. nodes in group: 5)

4

The buttons of group №3 (max. nodes in group: 5)

5

The buttons of group №4 (max. nodes in group: 5)

6

The buttons of group №5 (max. nodes in group: 5)

7

The buttons of group №6 (max. nodes in group: 5)

8

The buttons of group №7 (max. nodes in group: 5)

9

The buttons of scene №1 (max. nodes in group: 5)

10 The buttons of scene №2 (max. nodes in group: 5)

11 The buttons of scene №3 (max. nodes in group: 5)

12 The buttons of All On/Off (max. nodes in group: 5)

Содержание ZME RC2

Страница 1: ...ntrollers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated remote controls R This results in a number of possible communication patterns within a Z Wave network that are partly or completely supported by a specific...

Страница 2: ...nd should not be disposed of with household waste Battery Type 4 AAA Behavior within the Z Wave network I On factory default the device does not belong to any Z Wave network The device needs to join an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initia...

Страница 3: ...es are controlled using Basic Set On Off commands and SwitchMultilevel Dim Start Stop This mode implements communication pattern 7 Each button of the button group has different functions On short click turn on device s On pushed dim up light or wind up jalousie until button is released Off short click turn off device s Off pushed dim down light or wind down jalousie until button is released Status...

Страница 4: ... sleep state most of the time to save battery life time Communication with the device is limited In order to communicate with the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state Without such a controller communication may become impossible and or the ba...

Страница 5: ... another device is called association In order to control a different device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common...

Страница 6: ...er Number 10 Parameter Size 1 This parameter defines the command to be sent to devices of control group 1 when the related button is pressed association group 2 Value Description 0 Disabled 1 Switch On Off and Dim send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes Command to Control Group 2 association group 3 Par...

Страница 7: ... and Dim send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes Command to Control Group 5 association group 6 Parameter Number 14 Parameter Size 1 This parameter defines the command to be sent to devices of control group 5 when the related button is pressed association group 6 Value Description 0 Disabled 1 Switch On...

Страница 8: ...m send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes Command to Control Scene 1 association group 9 Parameter Number 17 Parameter Size 1 This parameter defines the command to be sent to devices of control scene group 1 when the related button is pressed association group 9 Value Description 0 Disabled 1 Switch On ...

Страница 9: ...ssociation group 11 Value Description 0 Disabled 1 Switch On Off and Dim send Basic Set and Switch Multilevel 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes Default 5 Send Preconfigured Scenes Command to Control group All On Off association group 12 Parameter Number 20 Parameter Size 1 This parameter defines the command to be sent to devices of control group All On Off when the rel...

Страница 10: ...tion version 1 Manufacturer Specific version 1 Protection version 1 Battery version 1 Wake Up version 2 Association version 2 Version version 1 Multi Channel Association version 2 Multi Channel version 3 Basic version 1 Multilevel Switch version 1 All Switch version 1 Scene Activation version 1 Controlled Command Classes Multi Channel version 3 Basic version 1 Multilevel Switch version 1 All Switc...

Страница 11: ...y one primary controller in a Z Wave network Inclusion is the process of bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node ...

Страница 12: ... PDQXDOV ZDYHHXURSH FRP PDNH SKS ODQJ HQ W SH VNX 0 B5 KWWS PDQXDOV ZDYHHXURSH FRP PDNH SKS ODQJ HQ W SH VNX 0 B5 ...

Отзывы: