Страница 1: ...ntrollers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated remote controls R This results in a number of possible communication patterns within a Z Wave network that are partly or completely supported by a specific...

Страница 2: ...nd should not be disposed of with household waste Battery Type 4 AAA Behavior within the Z Wave network I On factory default the device does not belong to any Z Wave network The device needs to join an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initia...

Страница 3: ...es are controlled using Basic Set On Off commands and SwitchMultilevel Dim Start Stop This mode implements communication pattern 7 Each button of the button group has different functions On short click turn on device s On pushed dim up light or wind up jalousie until button is released Off short click turn off device s Off pushed dim down light or wind down jalousie until button is released Status...

Страница 4: ... sleep state most of the time to save battery life time Communication with the device is limited In order to communicate with the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state Without such a controller communication may become impossible and or the ba...

Страница 5: ... another device is called association In order to control a different device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common...

Страница 6: ...er Number 10 Parameter Size 1 This parameter defines the command to be sent to devices of control group 1 when the related button is pressed association group 2 Value Description 0 Disabled 1 Switch On Off and Dim send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes Command to Control Group 2 association group 3 Par...

Страница 7: ... and Dim send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes Command to Control Group 5 association group 6 Parameter Number 14 Parameter Size 1 This parameter defines the command to be sent to devices of control group 5 when the related button is pressed association group 6 Value Description 0 Disabled 1 Switch On...

Страница 8: ...m send Basic Set and Switch Multilevel Default 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes Command to Control Scene 1 association group 9 Parameter Number 17 Parameter Size 1 This parameter defines the command to be sent to devices of control scene group 1 when the related button is pressed association group 9 Value Description 0 Disabled 1 Switch On ...

Страница 9: ...ssociation group 11 Value Description 0 Disabled 1 Switch On Off and Dim send Basic Set and Switch Multilevel 2 Switch On Off only send Basic Set 3 Switch All 4 Send Scenes Default 5 Send Preconfigured Scenes Command to Control group All On Off association group 12 Parameter Number 20 Parameter Size 1 This parameter defines the command to be sent to devices of control group All On Off when the rel...

Страница 10: ...tion version 1 Manufacturer Specific version 1 Protection version 1 Battery version 1 Wake Up version 2 Association version 2 Version version 1 Multi Channel Association version 2 Multi Channel version 3 Basic version 1 Multilevel Switch version 1 All Switch version 1 Scene Activation version 1 Controlled Command Classes Multi Channel version 3 Basic version 1 Multilevel Switch version 1 All Switc...

Страница 11: ...y one primary controller in a Z Wave network Inclusion is the process of bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node ...

Страница 12: ... PDQXDOV ZDYHHXURSH FRP PDNH SKS ODQJ HQ W SH VNX 0 B5 KWWS PDQXDOV ZDYHHXURSH FRP PDNH SKS ODQJ HQ W SH VNX 0 B5 ...