coMbustion air

Make-up outside air to the furnace for proper fuel combustion must 
be provided by openings to the outside of the building. The open-
ings of ducts supplying such make-up air shall have unobstructed 
areas not less than the area of the flue pipe.

note

Outside  air  is  needed  to  replace  the  air  used  by  the  burner 
and wood combustion process. Outside air is also required to 
replace the air used for taking the by-products of combustion 
of the gas or oil burner and wood/coal smoke out the chim-
ney. Outside air is also needed to replace any air expelled by 
kitchen  or  bathroom  fans  as  well  as  water  heater  chimneys 
or fans.

Failure to provide outside air to the area in which the furnace 
is located will result in a negative pressure or vacuum in the 
home.  Smoke  from  the  wood  fire  may  not  be  drawn  up  the 
chimney,  causing  creosote  buildup  and  sometimes  causing 
smoke to enter the furnace room.

Warning

You must provide for enough fresh air to assure proper com-
bustion. The fire in the furnace uses oxygen and must have 
a continuous supply. The air in a house contains only enough 
oxygen to supply the furnace for a short time. Outside air must 
enter the house to replace that used by the burner.

Содержание Klondike Eagle IV

Страница 1: ...pliance Alpha American Co 10 Industrial Blvd Palisade MN 56469 www yukon eagle com YUKON EAGLE OWNER S MANUAL Assembly Installation Operation Repair Parts Model No LW 000 Series CAUTION Read Rules And...

Страница 2: ...d during operation Do not operate with flue draft exceeding 03 W C Do not store flammable materials within marked installa tion clearances Frequently inspect and clean heat exchanger smoke pipe and ch...

Страница 3: ...8 Duct Work and Blower Speed Adjustment 18 Testing Installations for Efficiency 18 Test Procedure 10 MAINTENANCE Cleaning the Chimney Smoke Pipe and Heat Exchanger 19 In Case of Chimney Fire 19 Servic...

Страница 4: ...lt in failure of heat exchanger and cause dangerous operation 4 You must have a sufficient supply of combustion air to the area in which the furnace is located page 4 5 Factory Built Chimneys Connect...

Страница 5: ...should occur be sure ash door and firedoor are closed Turn thermostat down to close primary air damper In the event of an electrical power failure be sure ash door and fire door remain closed In the...

Страница 6: ...eat with second baffle making sure baffles interlock as shown in Fig 6 When properly installed baffles will not move more than 1 4 in any direction Failure to have baffles properly installed will seve...

Страница 7: ...pre selected location making sure it is level Proceed as follows Before Installing check DRAW COLLAR Attach the draw collar around the smoke pipe and tight against the furnace cabinet so room air cann...

Страница 8: ...r and place the 4 square box the furnished wiring harness over cable connector and replace the lock nut Secure the square box to the furnace with two sheet metal screws Connect the 34 long conduit to...

Страница 9: ......

Страница 10: ...ent outward into the collar and thus make a better joint WHEN FINISHED THE OPENING INTO THE FLUE MUST BE EQUAL IN SIZE TO THE COLLAR OF THE DRAFT CONTROL If flue pipe is made of material too heavy to...

Страница 11: ...stible wall is allowed if the space is insulated according to NFPA 90B table 6 5 1 2 DO NOT CONNECT THIS FURNACE TO A CHIMNEY SERVING ANOTHER APPLIANCE The chimney should be no less than 8 inches insi...

Страница 12: ...r chimney must terminate at least 2 feet above the peak of the roof Adding more chimney height sometimes cures the problem See Fig 12 page 14 5 Home located on side of hill When the wind blows over a...

Страница 13: ...You need two grilles each with 180 square inches of free opening Metal grilles have about 60 free open area so you need two metal grilles with 300 square inches each of louvered area The height should...

Страница 14: ...chim ney Outside air is also needed to replace any air expelled by kitchen or bathroom fans as well as water heater chimneys or fans Failure to provide outside air to the area in which the furnace is...

Страница 15: ...verload your furnace with wood Failure or damage to the firebox could result Never allow the hot coals to build up above the lower firebricks BEST WOOD TO BURN All solid fuel whether it is coal pine o...

Страница 16: ...ople and is recommended for use in this furnace Anthracite coal is hard and burns like the charcoal that is used in your barbecue grill The coals must touch each other to ignite Therefore the smaller...

Страница 17: ...e ash pan on a daily basis and should never be allowed to accumulate high enough to come in contact with the grates Such a condition could cut off necessary air circulation and could also result in a...

Страница 18: ...R CONDITIONING See air circulating fan performance curve charts on page 21 Service factors for factory furnished motors are 1 3 HP 1 35 1 2 HP 1 25 3 4 HP 1 15 All motors are Class A with Class B insu...

Страница 19: ...ainer until all cinders have thoroughly cooled CLEANING THE CHIMNEY SMOKE PIPE AND HEAT EXCHANGER Avoid chimney fires On a regular schedule check for creosote and soot buildup in the chimney smoke pip...

Страница 20: ...ht Check for obstruction such as loose mortar bird nests and squirrel nests Clean chimney to eliminate obstructions Check for obstructions in combustion air inlet See page 14 Too cold a chimney will c...

Страница 21: ...21...

Страница 22: ...22 9 10100700 10100700 lower upper...

Страница 23: ...23...

Страница 24: ...24 T 8000...

Страница 25: ...______________________________________________________________ _____________________________________________________________________________________ Notes _____________________________________________...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...TRACTOR ONLINE AT OUR WEBSITE OR FROM OUR FACTORY PHONE 1 800 358 0060 FAX 1 800 440 1994 E MAIL yukon mlecmn net WEBSITE www yukon eagle com Alpha American Co 10 Industrial Blvd Palisade MN 56469 www...

Отзывы: