TEMPERATURE CONTROLLER

18

USER

S MANUAL

19

As for option in wiring, Separated power lines from that of T/C can be

selected depending on customer’s preference. But also the other connector

out of YUDO standard could be equipped when those are supplied from

customer. In case that, a cable is fabricated according to special order,

Controller Connector must be fabricated in accordance with the Cable

Specification.

3) Options

NO

CONTROLLER

CONNECTOR

QUANTITY

1

1 ZONE

4P Round Jack

1 EA

2

2 ZONE

16 P

1 EA

3

3 ~ 4 ZONE

16 P

1 EA

4

5 ~ 6 ZONE

24 P

1 EA

5

7 ~ 8 ZONE

24 P

2 EA

6

9 ~ 12 ZONE

24 P

2 EA

7

13 ~ 16 ZONE

24 P

3 EA

8

17 ~ 20 ZONE

24 P

4 EA

9

21 ~ 24 ZONE

24 P

4 EA

24P FeMale heater connector  

24P Male T/C connector

240V 3Phase 3 Line Type

11. Diagram for Terminal Connection and Structure

12. Electric Wiring Diagram

Female connector is attached to the mainframe, and YUDO supply it with 4

pin, 16 pin and 24 pin as same to the following standard.

2) Standard specification  

As for Zone No.:Please refer to the standard spec.

Содержание CGF 560

Страница 1: ...566010 U K Mobile 98 912 2776072 e mail amin yudo co uk U S A YUDO INC HQ TEL 1 614 873 1300 FAX 1 614 873 6873 e mail slee yudousa com jaagaard yudousa com Central Division TEL 1 630 529 7487 FAX 1...

Страница 2: ...Mode 3 MANUAL Mode 7 Menu Setting 8 1 User s Setting Menu 2 Supplier s Setting Menu 8 Error Code Display Function 15 9 Integrated Control Function 16 10 Connector Cable 17 1 How to wire a Heater and...

Страница 3: ...9 Make it sure to earth ground wire of the controller Neglect to earth the ground wire green line can cause damage to fuse and Triac due to noise voltage 10 Turn on the Main Power Switch first 11 The...

Страница 4: ...ersion key 10 AUTO LED Displays Auto Mode is selected 11 STAND BY LED Displays Stand by Mode is selected 12 MANUAL LED Displays Manual Mode is selected 13 MODULE Handle 14 MODULE Power Switch 15 MODUL...

Страница 5: ...m as 50 C AL L Lowest Limit Alarm as 50 C AL H start at 250 C of measured temperature AL L at 150 C Output power is reduced to maintain at the STAND BY Temperature STAND BY Mode will finish after the...

Страница 6: ...75 Stand by Mode is operated for 1 hour and the Temperature for Standby Mode is set as 140 C 75 x 200 C Choose ON or OFF with key To save press and keys together This is provided to help the Integrat...

Страница 7: ...t Power for 1 minute at the beginning of Power Supply in order to check connection state of a heater and sensors and start smooth control action at low heat state Hold and keys for 3 seconds at the sa...

Страница 8: ...DESCRIPTION 1 tC oP Sensor Disconnection 2 tC St Sensor Short Circuit 3 tC rE Sensor Polarity Reverse 4 AL H High Limit Alarm 5 AL L The Low Limit Alarm 6 Ht oP Heater Disconnection 7 Ht St Heater Sh...

Страница 9: ...d STANDBY function Connector means a component attached to the end part of cable in order to make it easy to connect disconnect the wire to the mold controller Various kinds of connectors are used dep...

Страница 10: ...ation 3 Options NO CONTROLLER CONNECTOR QUANTITY 1 1 ZONE 4P Round Jack 1 EA 2 2 ZONE 16 P 1 EA 3 3 4 ZONE 16 P 1 EA 4 5 6 ZONE 24 P 1 EA 5 7 8 ZONE 24 P 2 EA 6 9 12 ZONE 24 P 2 EA 7 13 16 ZONE 24 P 3...

Страница 11: ...r 1 Power off 2 Open the back cover of controller 3 Separate all 3 blue sleeved wires from L1 L2 and L3 4 Plug all 3 blue sleeved wires into N Supply voltage 380V Supply voltage 220V Controller 220V C...

Страница 12: ...mold or it s coat is peeled so as to contact mold or line T C Sensor type between mold and controller is different EX CA K IC J IC J CA K Check point Check T C wire with tester When disconnected repl...

Отзывы: