TEMPERATURE CONTROLLER
16
USER
’
S MANUAL
17
Central Control for every modules in the frame box can be executed
effectively, with only one switch handling, i.e. STAND-BY or LOCK for every
module could be controlled simultaneously.
This function is available for CGF570(optional) model only.
When buzzer works with corresponding error codes in one or more modules
. You can stop the sound of the buzzer with only one handling (Only alarm
buzzer will stop. But it doesn’t mean that the cause of the error is removed).
In order to stop the production for a while on the way of normal operation,
you can select this function to reduce the Power Supply, with only one
handling.
This is a security function to prevent from any modifications of setting. You
can convert all modules into Lock ON/OFF Mode with only one handling.
1) AL/RE (Alarm RESET Function)
3) LOCK (LOCK ON function)
2) STBY (Integrated STANDBY function)
Connector means a component attached to the end part of cable in order to
make it easy to connect / disconnect the wire to the mold / controller. Various
kinds of connectors are used depending on load capacities.
16P Male standard connector
(2 ZONE~4 ZONE)
24P Male standard connector
(5 ZONE~24 ZONE)
1) How to wire a heater and T/C in connectors
9. Integrated Control Function (optional)
10. Connector and Cable
2
3
Malfunction on
heater
Fuse
Disconnection
Error classification
No
- Disconnection, Short Circuit, and Over Current of
heater can be detected. Short status of Output
Device(SSR,TRIAC, RELAY) can be checked also.
- On error occurrence, Heater Disconnection(Ht-oP),
Heater Short(Ht-St), and TRIAC short(tr-St) could be
displayed on SV. When the problem is solved, power
must be put again to recover Normal Operation.
- In case the fuse blown out, related fuse number is
displayed on SV.
- When the problem is solved, power must be put again
to recover Normal Operation.
Description
NOTE : # NO : ZONE NUMBER
Standard Spec. : Integrated wire(Power+T/C)
Optional Spec. : Separated wire(Power, T/C)