background image

TEMPERATURE CONTROLLER

16

USER

S MANUAL

17

Central Control for every modules in the frame box can be executed

effectively, with only one switch handling, i.e. STAND-BY or LOCK for every

module could be controlled simultaneously. 

This function is available for CGF570(optional) model only.

When buzzer works with corresponding error codes in one or more modules

. You can stop the sound of the buzzer with only one handling (Only alarm

buzzer will stop. But it doesn’t mean that the cause of the error is removed).

In order to stop the production for a while on the way of normal operation,

you can select this function to reduce the Power Supply, with only one

handling.

This is a security function to prevent from any modifications of setting. You

can convert all modules into Lock ON/OFF Mode with only one handling.

1) AL/RE (Alarm RESET Function)

3) LOCK (LOCK ON function)

2) STBY (Integrated STANDBY function)

Connector means a component attached to the end part of cable in order to

make it easy to connect / disconnect the wire to the mold / controller. Various

kinds of connectors are used depending on load capacities.

16P Male standard connector

(2 ZONE~4 ZONE)

24P Male standard connector

(5 ZONE~24 ZONE)

1) How to wire a heater and T/C in connectors

9. Integrated Control Function (optional)

10. Connector and Cable

2

3

Malfunction on
heater

Fuse
Disconnection

Error classification

No

- Disconnection, Short Circuit, and Over Current of

heater can be detected. Short status of Output
Device(SSR,TRIAC, RELAY) can be checked also.

- On error occurrence, Heater Disconnection(Ht-oP),

Heater Short(Ht-St), and TRIAC short(tr-St) could be
displayed on SV.  When the problem is solved, power
must be put again to recover Normal Operation.

- In case the fuse blown out, related fuse number is

displayed on SV. 

- When the problem is solved, power must be put again

to recover Normal Operation. 

Description

NOTE : # NO : ZONE NUMBER

Standard Spec. : Integrated wire(Power+T/C)

Optional Spec. : Separated wire(Power, T/C)

Содержание CGF 560

Страница 1: ...566010 U K Mobile 98 912 2776072 e mail amin yudo co uk U S A YUDO INC HQ TEL 1 614 873 1300 FAX 1 614 873 6873 e mail slee yudousa com jaagaard yudousa com Central Division TEL 1 630 529 7487 FAX 1...

Страница 2: ...Mode 3 MANUAL Mode 7 Menu Setting 8 1 User s Setting Menu 2 Supplier s Setting Menu 8 Error Code Display Function 15 9 Integrated Control Function 16 10 Connector Cable 17 1 How to wire a Heater and...

Страница 3: ...9 Make it sure to earth ground wire of the controller Neglect to earth the ground wire green line can cause damage to fuse and Triac due to noise voltage 10 Turn on the Main Power Switch first 11 The...

Страница 4: ...ersion key 10 AUTO LED Displays Auto Mode is selected 11 STAND BY LED Displays Stand by Mode is selected 12 MANUAL LED Displays Manual Mode is selected 13 MODULE Handle 14 MODULE Power Switch 15 MODUL...

Страница 5: ...m as 50 C AL L Lowest Limit Alarm as 50 C AL H start at 250 C of measured temperature AL L at 150 C Output power is reduced to maintain at the STAND BY Temperature STAND BY Mode will finish after the...

Страница 6: ...75 Stand by Mode is operated for 1 hour and the Temperature for Standby Mode is set as 140 C 75 x 200 C Choose ON or OFF with key To save press and keys together This is provided to help the Integrat...

Страница 7: ...t Power for 1 minute at the beginning of Power Supply in order to check connection state of a heater and sensors and start smooth control action at low heat state Hold and keys for 3 seconds at the sa...

Страница 8: ...DESCRIPTION 1 tC oP Sensor Disconnection 2 tC St Sensor Short Circuit 3 tC rE Sensor Polarity Reverse 4 AL H High Limit Alarm 5 AL L The Low Limit Alarm 6 Ht oP Heater Disconnection 7 Ht St Heater Sh...

Страница 9: ...d STANDBY function Connector means a component attached to the end part of cable in order to make it easy to connect disconnect the wire to the mold controller Various kinds of connectors are used dep...

Страница 10: ...ation 3 Options NO CONTROLLER CONNECTOR QUANTITY 1 1 ZONE 4P Round Jack 1 EA 2 2 ZONE 16 P 1 EA 3 3 4 ZONE 16 P 1 EA 4 5 6 ZONE 24 P 1 EA 5 7 8 ZONE 24 P 2 EA 6 9 12 ZONE 24 P 2 EA 7 13 16 ZONE 24 P 3...

Страница 11: ...r 1 Power off 2 Open the back cover of controller 3 Separate all 3 blue sleeved wires from L1 L2 and L3 4 Plug all 3 blue sleeved wires into N Supply voltage 380V Supply voltage 220V Controller 220V C...

Страница 12: ...mold or it s coat is peeled so as to contact mold or line T C Sensor type between mold and controller is different EX CA K IC J IC J CA K Check point Check T C wire with tester When disconnected repl...