On the basis of the Set Temperature, when the temperature become higher

than Setting Value, the AL-H function is operated.

When            key is held for 3 seconds, AL-H is displayed on PV, and the

High Limit Value for AL-H is displayed on SV.

The value can be set through 00~99 by using            ,           key, and the

Initial Value is set as 50 at the factory.

To save as Set Value, press           and            keys together.

TEMPERATURE CONTROLLER

8

USER

S MANUAL

9

On the basis of the set temperature, when the temperature is lower than the

Low Limit Setting Value, the AL-L function is operated.

For the first push            key for 3seconds, then press the key once again.

AL-L will be displayed on PV, and the Setting Value for the AL-L will be

displayed on SV.

The value can be set through -99~00, by using            ,            key,

and the Initial Value is set as -50 at the factory.

To save as Set Value, press            and             keys together.

Ex) In case SV(Temperature Setting) is set as 200¡C, AL-H(High Limit

Alarm) as 50¡C, AL-L(Lowest Limit Alarm) as -50¡C :

=>AL-H start at 250¡C of measured temperature, AL-L at 150¡C 

Output power is reduced to maintain at the STAND-BY Temperature.

STAND-BY Mode will finish after the given time, and move into AUTO

Mode

User

s can adjust Power Output by using           and            key for

Emergency Manual Operation at his will. 

When            key is pressed twice, for 1 seconds each at the Auto Mode, it

turns into Manual mode

If sensor detect any Disconnection of Thermocouple (tC.oP), or

Thermocouple Short (tC.St), it is converted into Manual mode

automatically for a emergency operation mode.

Setting Value(%) can be modified with            ,            keys.

Press           key for 3 seconds in order to start User’s setting menu.

key is used for selecting functions,            key for ON/OFF,

and            keys for change parameter. 

To save as Set Value, press            and            keys together. But also

Present Valve is replaced automatically as Set Value unless any key is

pressed for 5 seconds. 

Modifying Set Value must be done under LOCK OFF Mode.

3) MANUAL Mode

1) User's Setting Menu 

1-1) AL-H (High Limit Alarm Function)

1-2) AL-L (Low Limit Alarm Function)

User's setting menu diagram

7. Menu Setting

Содержание CGF 560

Страница 1: ...566010 U K Mobile 98 912 2776072 e mail amin yudo co uk U S A YUDO INC HQ TEL 1 614 873 1300 FAX 1 614 873 6873 e mail slee yudousa com jaagaard yudousa com Central Division TEL 1 630 529 7487 FAX 1...

Страница 2: ...Mode 3 MANUAL Mode 7 Menu Setting 8 1 User s Setting Menu 2 Supplier s Setting Menu 8 Error Code Display Function 15 9 Integrated Control Function 16 10 Connector Cable 17 1 How to wire a Heater and...

Страница 3: ...9 Make it sure to earth ground wire of the controller Neglect to earth the ground wire green line can cause damage to fuse and Triac due to noise voltage 10 Turn on the Main Power Switch first 11 The...

Страница 4: ...ersion key 10 AUTO LED Displays Auto Mode is selected 11 STAND BY LED Displays Stand by Mode is selected 12 MANUAL LED Displays Manual Mode is selected 13 MODULE Handle 14 MODULE Power Switch 15 MODUL...

Страница 5: ...m as 50 C AL L Lowest Limit Alarm as 50 C AL H start at 250 C of measured temperature AL L at 150 C Output power is reduced to maintain at the STAND BY Temperature STAND BY Mode will finish after the...

Страница 6: ...75 Stand by Mode is operated for 1 hour and the Temperature for Standby Mode is set as 140 C 75 x 200 C Choose ON or OFF with key To save press and keys together This is provided to help the Integrat...

Страница 7: ...t Power for 1 minute at the beginning of Power Supply in order to check connection state of a heater and sensors and start smooth control action at low heat state Hold and keys for 3 seconds at the sa...

Страница 8: ...DESCRIPTION 1 tC oP Sensor Disconnection 2 tC St Sensor Short Circuit 3 tC rE Sensor Polarity Reverse 4 AL H High Limit Alarm 5 AL L The Low Limit Alarm 6 Ht oP Heater Disconnection 7 Ht St Heater Sh...

Страница 9: ...d STANDBY function Connector means a component attached to the end part of cable in order to make it easy to connect disconnect the wire to the mold controller Various kinds of connectors are used dep...

Страница 10: ...ation 3 Options NO CONTROLLER CONNECTOR QUANTITY 1 1 ZONE 4P Round Jack 1 EA 2 2 ZONE 16 P 1 EA 3 3 4 ZONE 16 P 1 EA 4 5 6 ZONE 24 P 1 EA 5 7 8 ZONE 24 P 2 EA 6 9 12 ZONE 24 P 2 EA 7 13 16 ZONE 24 P 3...

Страница 11: ...r 1 Power off 2 Open the back cover of controller 3 Separate all 3 blue sleeved wires from L1 L2 and L3 4 Plug all 3 blue sleeved wires into N Supply voltage 380V Supply voltage 220V Controller 220V C...

Страница 12: ...mold or it s coat is peeled so as to contact mold or line T C Sensor type between mold and controller is different EX CA K IC J IC J CA K Check point Check T C wire with tester When disconnected repl...

Отзывы: